4592 ROUGH-IN

GENERAL INSTRUCTIONS

1. Water supply 3/8" O.D. unplated copper tube. Waste 1-1/4" O.D. Contractor to supply waste trap and

     service stop valve in accordance with local code.

2. Connecting lines to be made of unplated copper and should be thoroughly flushed to remove all foreign

     matter  before being connected to fountain.  This fountain is manufactured in such a manner that it does

     not in anyway cause taste, odor, color, or sediment problems.

3. Connect fountain to building supply line with a shut-off valve and install a 3/8" unplated copper waterline

     between the valve and the fountain. Remove any burrs from outside of water line and insert into inlet side

     of  the strainer (see Fig.1) to a positive stop - approximately 3/4". (see Fig.2) 

DO NOT SOLDER TUBES

     INSERTED INTO THE STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT.

4. These products are designed to operate on 20 psig to 105 psig supply line pressure. If inlet pressure is

     above 105 psig, a pressure regulator must be installed in the supply line. Any damage caused by reason

     of connecting this product to supply line pressures lower than 20 psig or higher than 105 psig is not

     covered by warranty.

LEGEND:

A

 = RECOMENDED WATER SUPPLY LOCATION, 3/8" O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2"  (38mm) OUT FROM

       WALL SHUT OFF VALVE BY OTHERS.

B

 = RECOMMENDED LOCATION FOR WASTE OUTLET, 1-3/4" O.D. (44mm) DRAIN.

C

 = (4) 5/16" (8mm) DIA. MOUNTING HOLES.

INSTALLATION INSTRUCTIONS

1. This fountain is to be mounted on a smooth, flat, finished wall surface with adequate support structure.

     

NOTE: Wall mounting structure must be capable of supporting 300 lb. load on fountain.

2. Establish rim height that fountain is to be mounted at.

3. Refer to rough-in for plumbing.

4. Locate and install trap. (trap not furnished)

5. Install shut-off valve on building water supply. (valve not furnished)

6. Locate and install fountain using 3/8" minimum lag screws or bolts. (screws or bolts not furnished)

7. Connect water supply and fountain drain.

8. Turn on water supply and check all connections for leaks.