96628C (Rev. SIC - 6/04)
PAGE 2
4591_FTN
FIG. 2
START UP
1. This fountain is to be mounted on a smooth, flat, finished surface
with adequate support structure.
NOTE: Mounting structure must be
capable of supporting 300 lb. load on fountain.
2. Refer to rough-in for plumbing.
3. Install shut-off valve on water supply. (valve not furnished)
4. Locate and install fountain using 3/8" minimum anchor screws or bolts.
(screws or bolts not furnished)
CAUTION:
This fountain is rated for inlet water pressure of 20-105 PSI.
A pressure reducing regulator should be used if the inlet water
supply exceeds 105 PSI.
5. Connect water supply and fountain drain. Water connection & drain
must comply with local codes.
6. Turn on water supply and check all connections for leaks.
ROUGH-IN DRAWING
FIG. 1
NOTE: WATER FLOW
DIRECTION
BUILDING WATER INLET
SERVICE STOP
(NOT FURNISHED)
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY