PAGE 5
4420DBFR_FTN _A LK4420DBFR_FTN_A
1000003947 (Rev. A - 06/17)
G
J
H
F
E
D
C
A
B
K
L
INSTRUCTIONS FOR CONNECTING TUBES FROM VALVE TO FOUNTAIN(S)
Step 1 - Insert the 1/8” O.D. tube(s) (Labeled A, B & J) into the connector(s) (provided with fountain). Insert the 1/8” O.D. tube(s)
coming from the fountain(s) push button actuator(s) into the connector(s). Trim any excess length.
Step 2 - Secure the 1/8” O.D. tube(s) (Labeled C, D & K) to the waste line assembly. This line is a vent line and should be open
to the air.
Step 3 - Insert the 1/4” O.D. tube(s) (Labeled E, F & L) into the 1/4” union(s) (provided with valve assembly). Insert the
1/4” O.D. water lines coming from the fountain(s) into union(s). Trim any excess length.
Step 4 - Insert the 1/4” O.D. tube (Labeled G) into the air gap assembly.
Step 5 - Secure the 1/4” O.D. tube (Labeled H) to the waste line assembly. This line is a vent line and should be
open to the air.
LABEL A
(ON/OFF CONTROL LINE
FOR BUBBLER ONE)
LABEL F
(WATER LINE)
LABEL G
(DRAIN LINE)
LABEL E
(WATER LINE)
LABEL B
(ON/OFF CONTROL LINE
FOR BUBBLER TWO)
LABEL C
(VENT LINE)
LABEL H
(VENT LINE)
LABEL D
(VENT LINE)
FOUNTAIN CONNECTIONS
FIG. 3
FOUNTAIN CONNECTIONS
PLUMBING CONDUIT
(BY INSTALLER)
TO VALVE
LABEL L
(Water Line)
LABEL K
(VENT LINE)
LABEL J
(ON/OFF CONTROL LINE
FOR BUBBLER THREE)