background image

2

FIXTURE BOXES

1. 

Line up the holes on the mounting bracket (B) with 

the holes on your junction box. Using either (2) #6 

screws or (2) #8 screws (D) (depending on size of 

the holes in your junction box), attach the mounting 

bracket (B) to your junction box (Fig. 5).

2.

  Thread fixture wires through mounting bracket (B) 

(Fig. 5). 

3. 

Hang one end of the support hook (F) onto the 

mounting bracket guide tabs and hang the light 

fixture on the other end of the support hook (Fig. 6).

4.  

Thread fixture wires through the gasket (C) and 

 connect fixture black wire to house black wire, 

 fixture white wire to house white wire, and fixture 

 ground wire to house ground wire using the 

 attached quick connectors (Fig.8).

5. 

Remove support hook (F) and attach fixture (A) to 

the mounting bracket (B) using (2) #8 x 1-1/4 in.  

screws (D) provided. Be sure no loose wires remain  

sticking out from underneath the coverplate. Insert  

the decorative screw cover caps (H) into the screw  

holes on the coverplate for a finished appearance  

(Fig. 7).

6. 

Apply silicone caulk around the edges of the 

coverplate to provide a watertight seal from 

rain and moisture.

7. 

Turn on power at main fuse/breaker box.

5-YEAR LIMITED WARRANTY

THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, 

WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING, BUT NOT LIMITED TO, ANY 

WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.

Cooper Lighting Solutions ("CLS") 

warrants to customers that, for a period of five years from 

the date of purchase, 

CLS

 products will be free from defects in materials and workmanship. 

The obligation of 

CLS

  under this warranty is expressly limited to the provision of replacement 

products. This  warranty is extended only to the original purchaser of the product. A 

purchaser’s receipt or other proof of date of original purchase acceptable to 

CLS

. This is 

required before warranty performance shall be rendered. This warranty does not apply to 

CLS

 

products that have been altered or repaired that have been subjected to neglect, abuse, 

misuse or accident  (including shipping damages). This warranty does not apply to products 

not manufactured by 

CLS

 which have been supplied, installed, and/or used in conjunction with 

CLS

 products. Damage to the product caused by replacement bulbs or corrosion or 

discoloration of brass components are not covered by this warranty. 

LIMITATION OF LIABILITY:

IN NO EVENT SHALL 

CLS

 BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUEN-

TIAL DAMAGES (REGARDLESS OF THE FORM OF ACTION, WHETHER IN CONTRACT, STRICT 

LIABILITY, OR IN TORT INCLUDING NEGLIGENCE), NOR FOR LOST PROFITS; NOR SHALL THE 

LIABILITY OF 

CLS

 FOR ANY CLAIMS OR DAMAGE ARISING OUT OF OR CONNECTED WITH THESE 

TERMS OR THE MANUFACTURE, SALE, DELIVERY, USE, MAINTENANCE, REPAIR OR 

MODIFICATION OF 

CLS

 PRODUCTS, OR SUPPLY OF ANY REPLACEMENT PARTS THEREFORE, 

EXCEED THE PURCHASE PRICE OF 

CLS

 PRODUCTS GIVING RISE TO A CLAIM. NO LABOR 

CHARGES WILL BE ACCEPTED TO REMOVE OR INSTALL FIXTURES. 

To obtain warranty service, please contact 

CLS

, at 1-800-334-6871, press option 2 for 

Customer Service, or via e-mail ConsumerProducts@

cooperlighting.com

 and include the 

following information:

• Name, address and telephone number

• Date and place of purchase

• Catalog and quantity purchase

• Detailed description of problem

All returned products must be accompanied by a Return Goods Authorization Number issued 

by the Company and must be returned freight prepaid. Any product received without a Return 

Goods Authorization Number from the Company will be refused. CLS is not responsible for 

merchandise damaged in transit. Repaired or replaced products shall be subject to the terms 

of this warranty and are inspected when packed. Evident or concealed damage that is made 

in transit should be reported at once to the carrier making the delivery and a claim filed with 

them.  

Reproductions of this document without prior written approval of 

CLS

 are strictly prohibited. 

 

For assistance, call 1-800-334-6871 or e-mail us at ConsumerProducts@

cooperlighting.com 

Printed in China

Round

1-1/2 in.

Octagonal

1-1/2 in.

4

8

Junction 

box

C

A

B

F

G

A

7

G

F

5

D

B

D

Junction box

6

E

 Problem

  

Cause / Solution

Light does not 
come ON.

No power to the fixture.

• Check if circuit breaker tripped.
• Confirm wall switch is ON.

TURN OFF POWER BEFORE CONTINUING

Wiring to the unit is loose.

• Confirm wiring is properly secured.

* If light still does not come on after checking wiring 

connections, contact Customer Service.

Light flashes

Make sure fixture is not on the same circuit as any dimmer,  
or ceiling fan

WALL AND EAVE SURFACE MOUNT FIXTURE BOXES
PART 1: ATTACHING ADAPTER PLATE TO FIXTURE BOX

For use with 4” round fixture box
1. 

Determine the proper orientation of the adapter 
plate based on your fixture box location.  You may 
need to drill out the alternate mounting holes to 
properly mount the adapter plate to your fixture box 
using a 7/32” drill bit.

2. 

Peel off the adhesive side of gasket (E) and place on 
the bottom of the adapter plate (A), making sure to 
line up the holes in the gasket with the plate (Fig. 1).

3. 

Route supply wires through center hole of adapter 
plate (A).

4. 

Place two screws (C) or (D) through two holes 
in adapter plate (A) and align with fixture box (not 
included). Tighten down both screws (Fig. 2).

5. 

Apply silicone caulk around the edges of the fixture 
box and adapter plate.

A

Fig. 1

E

PART 2: ATTACHING FLOOD LIGHT FIXTURE TO ADAPTER PLATE

6. 

Peel off the adhesive side of the gasket included 
with the fixture and place on top of the adapter 
plate (A) (Fig. 3).

7. 

Make all electrical connections using wire nuts 
included with the fixture. Refer to fixture instruction 
sheet for detailed wiring instructions.

NOTE:

 Ensure that all ground wires are attached.

8. 

Line up the holes on the fixture’s coverplate with 
the holes on the adapter plate (A). Attach fixture 
to the adapter plate (A) using the two #8-32 x 1-¼” 
screws included with the fixture (Fig. 4).

9. 

Insert decorative screw cover caps (included with 
the fixture) into the coverplate holes for a finished 
appearance.

10.  

Apply silicone caulk to provide a watertight seal 
from rain and moisture.

Fig. 3

Fig. 4

TROUBLESHOOTING

C

A

Fig. 2

D

Summary of Contents for FSL503TB

Page 1: ...wer at fuse or circuit breaker before installing or servicing CAUTION Connect fixture to a 120 277 volt 50 60 Hz power source Any other connection voids the warranty Fixture should be installed by persons with experience in household wiring or by a qualified electrician The electrical system and the method of electrically connecting the fixture to it must be in accordance with the National Electri...

Page 2: ...in warranty service please contact CLS at 1 800 334 6871 press option 2 for Customer Service or via e mail ConsumerProducts cooperlighting com and include the following information Name address and telephone number Date and place of purchase Catalog and quantity purchase Detailed description of problem All returned products must be accompanied by a Return Goods Authorization Number issued by the C...

Page 3: ...t pas expressément approuvée par le fabricant peut annuler le droit de l utilisateur à faire fonctionner cet équipement CONSERVEZ CES INSTRUCTIONS POUR DES RÉSULTATS OPTIMAUX Installez le luminaire à 3 05 à 4 57 m 10 à 15 pi au dessus du sol Si vous installez deux luminaires sur un seul interrupteur vérifiez qu il est conçu pour supporter une charge inductive d au moins 1A Lors d une installation ...

Page 4: ...on En vertu de la présente garantie l obligation de CLS se limite expressément à fournir des produits de remplacement La présente garantie n est proposée qu à l acheteur initial du produit CLS requiert un reçu ou autre preuve d achat qu elle jugera acceptable sur lequel est indiquée la date de l achat initial Cette preuve d achat est requise pour obtenir l exécution de la garantie La garantie ne s...

Page 5: ...INSTRUCCIONES PARA OBTENER LOS MEJORES RESULTADOS Instale la luminaria a 10 15 pies 3 4 5 m sobre el suelo Cuando instale dos luminarias en el mismo interruptor asegúrese de que esté clasificado al menos para una carga inductiva 1A AJUSTE DE LA TEMPERATURA DEL COLOR Estos accesorios cuentan con un ajuste de color blanco seleccionable que le permite elegir entre tres colores de luz preestablecidos ...

Page 6: ...se provoque durante el transporte se debe informar de inmediato al transportista que realiza la entrega y se debe presentar un reclamo La reproducción de este documento sin la aprobación previa por escrito de CLS está estrictamente prohibida Para solicitar ayuda llame al 1 800 334 6871 o envíe un correo electrónico a ConsumerProducts cooperlighting com Impreso en China 1121 Highway 74 South Peacht...

Reviews: