Cooling fan 

The equipment is designed with internal fans to ensure that the product runs within the proper 

temperature range. When the device is working hard, it will automatically turn on the fan. During 

discharging and charging, the fan may run intermittently to keep the internal temperature within 

the operating range. When the AC circuit is activated, the fan is likely to start to ensure normal 

operation.

Power saving sleep mode 

① When the power station is not plugged in to the wall outlet, and no output ports are enabled,  

it will enter sleep mode in 5-8 minutes.
② When the unit is fully charged, the LCD will display the battery level at 100% and input power  

is 0W. The LCD will turn off automatically.  
③ If the output ports are ON and the power is lower than certain level, the device will turn OFF all 

outputs then enter sleep mode in 8 hours. (USB<5W, DC<5W, AC<25W)

Equipment cleaning

Please make sure that the device is disconnected from all input power and output devices. Wipe 

with a clean, dry, non-soft cotton cloth. Remove all any foreign objects, dirt or other obstructions 

on the vents on both sides. While cleaning foreign objects in the side vents, do not allow debris, 

dirt or other blockage to enters the equipment. 
Do not use corrosive cleaners or solvents.
Do not use compressed air to clean the side cooling vents, as it will cause foreign particles to enter 

the interior and cause a short circuit.

Note: To avoid the risk of electric shock, do not use metal objects to clean the ports. 

Storage

If it will be stored for more than 1 month, please charge it to 50% capacity and keep it indoors,  

at normal temperature, and the maximum storage time shall not exceed 6 months. Please keep it 

away from direct sunlight.
Excessive temperature will lead to reduced service life, overheating and fire. Extremely cold 

conditions below the specified storage range can also impair the performance and service life of 

the equipment. Please keep away from corrosive chemicals and gases. 
After taking it out of storage, perform a visual inspection to ensure that the appearance of the 

equipment and all accessories are qualified. Check the vents on the intake and exhaust sides to 

make sure they are free of foreign objects.

Dynamic Voltage Adjustment

Dynamic Voltage Adjustment (DVA) technology allows your power station to perform beyond its 

standard 1600-watt level rating so it can run power tools and appliances with heating elements up 

to 2000-watts.

OPERATING INSTRUCTIONS

Re-charging 

Use the original AC cable to charge, the full charge time is about 1.8-2.8 hours. When charging, the 

LCD screen will be lit, the LCD display will provide real-time display data of battery charging, and 

the device will display 100% when it is fully charged. It is recommended to fully charge the device 

every 3 months to maintain the life of the device. 

Output Ports

While the power station is powered on, press the power button for the corresponding ports  

to enable the output(s), an icon will also be lit on the display.

Overload Condition 

If the AC and USB outputs are overloaded or short-circuited, the device will automatically turn off 

the output power. The code "E07" will be displayed on the LCD screen.
If the DC output is overloaded or short-circuited, the device will automatically turn off the output 

power. The code "E08" will be displayed on the LCD screen.

Power On/Off 

Long press the power ON/OFF button for 2-3 seconds to turn the power station on or off. The 

power station must be powered on before enabling output ports. 

How to switch frequency?

The device can intelligently identify the frequency of voltage when charging, and can automatically 

set the frequency, so please charge before using. After plugging in the charging cable, the display 

will show the frequency of current grid voltage as 50Hz or 60Hz.

Summary of Contents for 1600

Page 1: ...POWER STATION 1600 FOR ALL QUESTIONS ABOUT THE WARRANTY OR EXCHANGE REQUESTS CONTACT US 1 800 255 6061 Operating Instructions PLEASE READ BEFORE OPERATING THIS EQUIPMENT...

Page 2: ...specified input voltage DO NOT use the unit if it is not functioning correct DO NOT move the unit if it is recharging or in use WARNING Noncompliance may lead to serious injury or death Use and store...

Page 3: ...charges Camera 5 9Wh Around 177 Recharges Game Console 16Wh Around 65 Recharges Floodlight 5W Around 208 hours MORE HaloPower Station1600 UserManual ACChargingCable DC12V toAndersonCable DC5525 toAnde...

Page 4: ...on the unit first Press the button to turn the DC 12V output on Press again to turn off Button USB Output Turn on the unit first Press the button to turn the USB A and USB C output on Press again to t...

Page 5: ...UPS An uninterruptible power supply UPS is backup feature that provides near instantaneous power in the event of an unexpected power failure or outage which protect sensitive equipment from damage Dev...

Page 6: ...t will shut off Disconnect the loads 12V car charger Use the car charger we provided to charge It takes 18 hours to fully charge When the LCD shows that the battery power is 100 it means that the batt...

Page 7: ...re Extremely cold conditions below the specified storage range can also impair the performance and service life of the equipment Please keep away from corrosive chemicals and gases After taking it out...

Page 8: ...ement The device can be used in portable exposure condition without restriction TRANSPORT INSTRUCTIONS FOR DANGEROUS GOODS The HALO Power Station 1600 meets all legal requirements for the transportati...

Page 9: ...UNINTERRUPTIBLE POWER SUPPLY UPS Switching Time 10 milliseconds ms PRODUCT Dimensions 16 9 x 11 3 x 11 8 inches 42 92 x 28 7 x 29 97 cm Weight 44 42 lb 20 15 kg LIMITED WARRANTY At HALO we are dedicat...

Page 10: ...PRODUCT REGISTRATION www HALOPOWER com...