Cooling fan
The equipment is designed with internal fans to ensure that the product runs within the proper
temperature range. When the device is working hard, it will automatically turn on the fan. During
discharging and charging, the fan may run intermittently to keep the internal temperature within
the operating range. When the AC circuit is activated, the fan is likely to start to ensure normal
operation.
Power saving sleep mode
① When the power station is not plugged in to the wall outlet, and no output ports are enabled,
it will enter sleep mode in 5-8 minutes.
② When the unit is fully charged, the LCD will display the battery level at 100% and input power
is 0W. The LCD will turn off automatically.
③ If the output ports are ON and the power is lower than certain level, the device will turn OFF all
outputs then enter sleep mode in 8 hours. (USB<5W, DC<5W, AC<25W)
Equipment cleaning
Please make sure that the device is disconnected from all input power and output devices. Wipe
with a clean, dry, non-soft cotton cloth. Remove all any foreign objects, dirt or other obstructions
on the vents on both sides. While cleaning foreign objects in the side vents, do not allow debris,
dirt or other blockage to enters the equipment.
Do not use corrosive cleaners or solvents.
Do not use compressed air to clean the side cooling vents, as it will cause foreign particles to enter
the interior and cause a short circuit.
Note: To avoid the risk of electric shock, do not use metal objects to clean the ports.
Storage
If it will be stored for more than 1 month, please charge it to 50% capacity and keep it indoors,
at normal temperature, and the maximum storage time shall not exceed 6 months. Please keep it
away from direct sunlight.
Excessive temperature will lead to reduced service life, overheating and fire. Extremely cold
conditions below the specified storage range can also impair the performance and service life of
the equipment. Please keep away from corrosive chemicals and gases.
After taking it out of storage, perform a visual inspection to ensure that the appearance of the
equipment and all accessories are qualified. Check the vents on the intake and exhaust sides to
make sure they are free of foreign objects.
Dynamic Voltage Adjustment
Dynamic Voltage Adjustment (DVA) technology allows your power station to perform beyond its
standard 1600-watt level rating so it can run power tools and appliances with heating elements up
to 2000-watts.
OPERATING INSTRUCTIONS
Re-charging
Use the original AC cable to charge, the full charge time is about 1.8-2.8 hours. When charging, the
LCD screen will be lit, the LCD display will provide real-time display data of battery charging, and
the device will display 100% when it is fully charged. It is recommended to fully charge the device
every 3 months to maintain the life of the device.
Output Ports
While the power station is powered on, press the power button for the corresponding ports
to enable the output(s), an icon will also be lit on the display.
Overload Condition
If the AC and USB outputs are overloaded or short-circuited, the device will automatically turn off
the output power. The code "E07" will be displayed on the LCD screen.
If the DC output is overloaded or short-circuited, the device will automatically turn off the output
power. The code "E08" will be displayed on the LCD screen.
Power On/Off
Long press the power ON/OFF button for 2-3 seconds to turn the power station on or off. The
power station must be powered on before enabling output ports.
How to switch frequency?
The device can intelligently identify the frequency of voltage when charging, and can automatically
set the frequency, so please charge before using. After plugging in the charging cable, the display
will show the frequency of current grid voltage as 50Hz or 60Hz.