Page
2
of
2
75.5293.03
20090317
Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem, please
contact BEA Inc. If you must wait for the following workday to contact BEA, leave the door inoperable until satisfactory
repairs can be made. Never sacrifice the safe operation of the automatic door or gate for an incomplete solution.
The following numbers can be called 24/7. For more information, visit
www.beasensors.com
.
7 Company Contact
US and Canada:
Canada:
Northeast:
1-866-249-7937
1-866-836-1863
1-866-836-1863
Southeast:
Midwest:
West:
1-800-407-4545
1-888-308-8843
1-888-419-2564
1.
Inspect the frame header to determine if an angle bracket or filler plate is required.
2.
Fold the enclosed mounting template on the dotted line and then mark and drill
holes as indicated. Drill two 1/8” (3.1 mm) holes at the locations marked ‘B’. For
single doors, locate the template against the door and header on the lock jamb
side of the frame.
3.
Disassemble the mounting plate from the maglock assembly using the enclosed
hex key. Insert 2 screws into the slotted holes and secure the mounting
plate to the doorframe using two of the #8 mounting screws. Do not
tighten these screws fully until the maglock is properly aligned.
4.
Gently tap (2) 3/16” (5mm) spring pins into the rear side of
the armature(s). Drill matching holes on the door to
receive these pins.
5.
Align armature/strike plate to magnet, and then
drill a 5/8” (16mm) hole in door for sexnut and
aluminum reinforcement tube for hollow doors.
Using the M8 x 1.25 x 40mm hex head screw
and enclosed hex key, mount armature to door
using two metal and one rubber washers.
6.
Continue to fasten mounting plate to heading
using remaining screws. Then, reassemble
maglock assembly to mounting plate.
7.
Route the enclosed wiring harness through
the rectangular hole in the mounting plate.
Make the electrical connection as shown
below.
8.
Make sure that armature/strike plate can be
shaken slightly. This will permit full armature
contact and maximize holding force.
5 Installation - Mechanical
6 Installation - Electrical
ARMATURE /
STRIKE PLATE
MOUNTING PLATE
MOUNTING
SCREWS
MAGLOCK
ASSEMBLY
MOUNTING PLATE
ASSEMBLY SCREWS
TUBES
ARMATURE / STRIKE
PLATE SCREW
RED
BLACK
DC
POWER
SUPPLY
- ONLY -
SWITCH