Tafonius
Junior
– A User Guide
SYSTEM FULL.........................................................................................................18PISTON POSITION INFO ERROR .........................................................................18
Alarms.......................................................................................................................... 19
* OXYGEN SUPPLY PRESSURE LOW *...............................................................19* OXYGEN SUPPLY PRESSURE LOW *...............................................................19* LOW BREATHING SYSTEM PRESSURE *.........................................................19* BATTERY 1 CRITICALLY LOW * and/or..............................................................19* BATTERY 2 CRITICALLY LOW *.........................................................................19* NO RESPONSE TO INPUT KNOBS *..................................................................19* RD VACUUM FAILURE *.....................................................................................19
Technical Specifications:..................................................................................................20
PHYSICAL ..................................................................................................................20ELECTRICAL...............................................................................................................20CLINICAL.....................................................................................................................20
Printed: 26/Oct/18
Page 4 of 20
DOCA4962B
TOC
Page 1: ...Tafonius JunioR J2 A USERS GUIDE v01Jun2017 Printed 26 Oct 18 DOCA4962B...
Page 2: ...Tafonius Junior A User Guide Notes Printed 26 Oct 18 Page 2 of 20 DOCA4962B TOC...
Page 3: ...EP 13 Dump Valve Button 13 Buffer Volume Setting 14 Controls on the Anesthesia Machine Side 14 Oxygen Flowmeter 14 Air Flowmeter 14 N2O Flowmeter 14 Oxygen Flush Button 14 Scavenging Flowmeter 14 Pres...
Page 4: ...SSURE LOW 19 OXYGEN SUPPLY PRESSURE LOW 19 LOW BREATHING SYSTEM PRESSURE 19 BATTERY 1 CRITICALLY LOW and or 19 BATTERY 2 CRITICALLY LOW 19 NO RESPONSE TO INPUT KNOBS 19 RD VACUUM FAILURE 19 Technical...
Page 5: ...nly Junior sans gas for use with an existing gas machine Junior sans gas Shown here with a Matrx VML by Midmark gas machine head Printed 26 Oct 18 Page 5 of 20 DOCA4962B TOC 6 152mm Locking Front Cast...
Page 6: ...thing Circuit connection port qVGA Display Soft Power Switch Future RM button Optional two position Select a TEC backbar Scavenging flowmeter RCD GFCI mains breaker Mains fuses Power cord Gas hose han...
Page 7: ...nd air Only features additional to those in the ventilator only version above are labeled below Printed 26 Oct 18 Page 7 of 20 DOCA4962B TOC Vaporizer mounting locations CO2 Absorber pan Patient Wye 2...
Page 8: ...ersion 6021 with Boot Loader ver 106 followed buy the Runtime in the format hours on hours ventilating Next the battery voltages are checked The result of this and each subsequent test is displayed on...
Page 9: ...ed Follow the instructions on the screen Fit a stopper to the patient wye piece turn on the gas flow to bring the breathing system pressure up to 20 cmH2O Adjust the flow rate to hold the pressure ste...
Page 10: ...d in this area as seen above The display of warning and error messages will replace the machine name when they occur 2 Piston Graphic and Settings Information Area 2 shows a representation of the pist...
Page 11: ...w other parameters are affected by the change being made One can therefore set a dependent variable For example you can set the MV by changing the TV and or the RR and watch the resulting affect on th...
Page 12: ...nes maximum capacity of 900 lpm inspiratory flow When a limit is reached the setting will not advance as the knob is turned THE CONTROL KNOBS Tidal Volume The range is 0 1L to 20 0L in 0 1L increments...
Page 13: ...el the ASSIST function This is a new feature and we currently have no guidelines on sensitivity values to set The software offers a range of between 1 LPM and 200 LPM as trigger values We would welcom...
Page 14: ...uld on any other anaesthesia machine Air Flowmeter An optional air flowmeter with either a yellow knob for the US or a black and white knob for most other countries may be installed on your machine Th...
Page 15: ...volume are used to control the size of the Virtual Bag the volume under the piston in Junior The piston is not allowed to rise above the combined volumes of TV BV Whenever the piston volume reaches th...
Page 16: ...pendant parameters such as minute volume inspiratory flow etc are not affected by these measurements and reflect only their calculated values based on the settings for TV RR and Itime Junior and IPPV...
Page 17: ...t or ceiling drop via a properly color coded hose to the DISS or NIST Vacuum or EVAC connector below the scavenging flowmeter at the right rear side of the machine In addition a 5 litre reservoir bag...
Page 18: ...E VOLUME The piston has entered the low volume zone at the 1 5L point If this is during an active inspiratory phase then a litre of gas will automatically be added to the breathing system through the...
Page 19: ...when the patient takes a breath at the same time as the ventilator delivers a breath The Alarm will continue until either a pressure in excess of 7cm H2O is registered during an inspiratory phase OR t...
Page 20: ...racy better that 25ml Buffer Volume BV 2 0 L to 20 L Respiratory Rate 1 0 to 30 0 bpm RR settings resolution 1 0 to 2 0 bpm 0 2 bpm 2 0 to 5 0 bpm 0 5 bpm 5 0 to 30 0 bpm 1 bpm Inspiratory Time 0 5 to...
Page 21: ...01A4313 120 3048mm BREATHING BAG 200A4980 VACUUM RESERVOIR CO2 ABSORBENT 202A2906R 60 TUBE SIDE STREAM GAS SAMPLING TUBE ASSY 200A4453 C VACUUM PUMP AMBIENT 2X 180A3241 VALVE BLOCK O RING D 1 8 27 FNP...
Page 22: ...This Page Left Intentionally Blank Section End...
Page 23: ...d turn it OFF 2 Remove the expandable drain clamp from either tube under the bottom pan 3 Fit the manual breathing tube over the pipe 4 Attach the bag to the connector on the side of the machine The O...
Page 24: ...ing by undoing the 4 Velcro retainers Remove the Y circuit from the ventilator Flush clean and hang to dry Undo and remove the 6 thumbscrews holding the valve block cover Remove and clean the valve ho...
Page 25: ...A3239 ABSORBER PAN 000A4621 BOTTOM PAN DIVIDER SEAL 180A4639 LINEAR ACTUATOR PISTON COVER UPPER CYLINDER HALF PISTON LOWER CYLINDER HALF BOTTOM PAN INSPIRATORY FLOW EXPIRATORY FLOW VACUUM HOLDS SILICO...
Page 26: ......
Page 27: ...damaged sampling pressure lines seals and gaskets rolling diaphragms etc The service strip down and re assembly will include but is not limited to Visual assessment Check the battery integrity power c...
Page 28: ...stomer s responsibility to schedule service dates within the Extended Warranty or Annual Service timeframe Manufacturers Warranty Please see our Tafonius Limited Warranty Statement for Full Details Ha...
Page 29: ...y with required Annual Service Call for an appointment Annual Service 4 500 No Charge 20 Discount TBD 12 months on entire machine4 Eligibility for Extended Warranty for 12 months 1 Time Travel time bi...
Page 30: ...wivel valve block permits the breathing tubes to exit to the right or the left n Stainless hoop handle and bumpers n GFI protected with 3 auxiliary AC power outlets n Panel mount e cylinder pressure g...
Page 31: ...ius junior Sans gas For use with your current gas machine Pictured with Matrx VML by Midmark Small Animal Machines 1500 3000 ml TV 300 1600 ml TV 20 350 ml TV 5 200 ml TV Model 2002 PRO One Machine th...