Hall Research Technologies UVA-WP Manual Download Page 14

 

 

Model UVA-WP 

12 

This effect gets worse at high resolutions, high refresh rates, long 

cables (in excess of 200 feet), and depends on the cable construction 

itself. Hall Research highly recommends the use of UTP cables 

specifically constructed for video transmission. In these cables all of 

the twisted pairs are the same length and are available from several 

sources including Hall Research (part numbers shown below). 

Zero-Skew CAT5 Cable for use with Hall Research CAT5 Products 

PART NUMBER 
CUTP-Z-1000-BLK  1000 ft.   

Zero-Skew CAT5 cable. Bulk spool of 1000 ft  

CUTP-ZP-1000-BLK 1000 ft.  

Zero-Skew CAT5 cable. Bulk spool of 1000 ft 

Plenum Rated   

 

If for some reason you are unable to use zero-skew Cat5 cable and 

have a long cable run, and will be displaying high-resolution PC image 

(such as a spread-sheet with small fonts), then you may need to 

purchase an Model SKU-RGB skew corrector or a Model URA-SKU 

which will re-align the RGB components of the video signal at the 

remote (or local) end. 

 

 

 

 

 

 

 

 

Model SKU-RGB  

Model URA-SKU 

 

Summary of Contents for UVA-WP

Page 1: ...l free in the U S 800 959 6439 FREE technical support Call 714 641 6607 or fax 714 641 6698 Mail order Hall Research 1163 Warner Ave Tustin CA 92780 Web site www hallresearch com E mail info hallresea...

Page 2: ......

Page 3: ...provide reasonable protection against such interference when the equipment is operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in...

Page 4: ...nto a Wall Desk or Podium 5 2 3 Connecting the Power Supply 6 2 4 Connecting the Transmitter to the Receiver 8 2 5 Adjusting Cable Length Compensation 9 3 Operation 11 3 1 UTP Cable Recommendations 11...

Page 5: ...ear of the unit features a standard RJ45 connector In instances where the input video is YPbPr requires a 3 RCA to HD15 adapter cable or if your PC does not provide power on its pin 9 of HD15 connecto...

Page 6: ...2 1 Package Contents The Model UVA WP comes with the following items Wallplate with attached circuit board male male VGA and 3 5mm Audio input cables approx 6 ft long A power supply o For North Americ...

Page 7: ...ower supply to the transmitter so that if a source with no power is encountered you will still be able to transmit the signal For new construction you need a single gang switchbox of any depth since t...

Page 8: ...is also a 2 5 mm Jack included in the package so that you don t have to cut the connector at the end of the supply If you decide to cut the connector at the end of the supply then you have to connect...

Page 9: ...t and wire it to the terminals on the back of the UVA WP Electrical Safety Note Since the DC supply to the unit is only 6 volts with minimal current requirements the product qualifies as a Class 2 low...

Page 10: ...e Use EIA TIA 568B standard straight through patch wiring as shown below Do not use crossover cables EIA TIA 568B WIRING STANDARD PIN Wire Color 1 White w Orange Stripe 2 Orange 3 White w Green Stripe...

Page 11: ...line is properly wired and that a protective ground green wire is established with NO potential difference between both the sender and receiver locations The splitter can tolerate up to 5 vPeak Peak g...

Page 12: ...video image The video quality at the remote station depends on 1 The length of the CAT5 cable 2 The video resolution setting 3 The video refresh rate setting In general at low and mid resolutions exce...

Page 13: ...rates Therefore for a given length of Cat 5 cable the total length of a particular pair could be longer than others Since the signals travel in the cable at a fixed speed the arrival times of signals...

Page 14: ...n below Zero Skew CAT5 Cable for use with Hall Research CAT5 Products PART NUMBER CUTP Z 1000 BLK 1000 ft Zero Skew CAT5 cable Bulk spool of 1000 ft CUTP ZP 1000 BLK 1000 ft Zero Skew CAT5 cable Bulk...

Page 15: ...his is usually an indication of improper grounding either at the sending end the receiving end or both Verify that the AC line is properly wired and that a protective ground green wire is established...

Page 16: ...ts Opening the unit without written authorization from Hall Research will void the warranty Contact the Hall Research technical support department at 714 641 6607 Before you do make a record of the hi...

Page 17: ...ts peak to peak Audio Transmission Line level mono with simulated stereo output Maximum Distance Up to 1000 ft 305 meters See table 2 1 for details Compliance CE FCC Part 15 Subpart B Class A IC Class...

Page 18: ......

Page 19: ......

Page 20: ...Copyright 2009 Hall Research Inc All rights reserved 1163 Warner Ave Tustin CA USA Ph 714 641 6607 Fax 714 641 6698 Designed and Made in the USA...

Reviews: