Hall Research Technologies HR-4P Manual Download Page 1

 

 

 

 

 

HR-4P 

Programmable Controller 

 

 
 

 
 
 

Order toll-free in the U.S. 800-959-6439 
FREE technical support, Call 

714-641-6607

 or fax 

714-641-6698 

Mail order:  

Hall Research

, 1163 Warner Ave. Tustin, CA 92780 

Web site: www.hallresearch.com   E-mail: [email protected] 

CUSTOMER 
SUPPORT 
INFORMATION 

UMA1164 Rev. NC 

Summary of Contents for HR-4P

Page 1: ...in the U S 800 959 6439 FREE technical support Call 714 641 6607 or fax 714 641 6698 Mail order Hall Research 1163 Warner Ave Tustin CA 92780 Web site www hallresearch com E mail info hallresearch co...

Page 2: ......

Page 3: ...lass A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules which are intended to provide reasonable protection against such interference when the equipment is o...

Page 4: ...Installation Overview 6 3 2 Installation Prerequisites 6 3 3 Software GUI Installation 6 3 4 Using the Software 7 3 5 Button Selection 7 3 6 Connect Disconnect 7 3 21 Tools 16 4 Final Installation 18...

Page 5: ...ication available on line at http www hallresearch com or on CD upon request that is used to easily create complex control sequences that describe the desired actions and to then upload them into the...

Page 6: ...ower supply 110 220 vAC 50 60 hZ with power cord 1 Users Manual 1 HR 4P Controller NOTE The user needs to supply the appropriate RS232 cable normally NULL MODEM to connect the HR 4P to a PC in order t...

Page 7: ...ion will be required For example an electrical schematic or drawing that shows how the HR 4P to the other electrical equipment such as switches or relays A Windows compatible PC is required to program...

Page 8: ...new PCs come with Microsoft NET Framework 2 0 or later already installed If NET Framework 2 0 or later is not installed on your PC it can be found on the Microsoft website 3 3 Software GUI Installatio...

Page 9: ...computer o Click the Communications tab to verify or change the COM port selection This setting will be remembered for future use o To open a serial connection to the unit click the Connect button on...

Page 10: ...he GUI by clicking the Download button displayed on the left of the main screen Figure 5 Sample Configuration Display 3 8 Download Click the Download button on the left of the Main screen to retrieve...

Page 11: ...o A configuration string can be created to perform one or more specific actions based on a particular condition o A configuration string can be up to 250 bytes long and it can be any combination of s...

Page 12: ...e you may have a projector configuration string like PWR_ON followed by a DELAY followed by an OUTPUT There is no limit to the number of actions that can be added as long as the 250 character limit is...

Page 13: ...R When done the user clicks the Add button to append the command to the existing user string as shown in Figure 8 Figure 8 IR Codes Up to 32 IR Codes that have been learned can be transmitted from the...

Page 14: ...the Add button to append the command to the existing user string to the existing user string as shown in Figure 10 Figure 10 Time Delay 3 14 Output If any of the units I O is configured as an output y...

Page 15: ...as inputs may have the current status read by clicking the I O Status button Any I O configured as outputs may have the output state set by selecting the appropriate control button RTS is an OUTPUT CT...

Page 16: ...ed into 1 of 32 IR Memory locations in the unit IR codes stored in memory can an 8 character name associated with it making it easier to be identified later o Check the IR Enabled box o To LEARN IR Co...

Page 17: ...to select a COM port of your PC to talk to the HR 4P unit Once the preferred COM port is selected pressing the Connect button either in this tab page or on the left of the Main screen to make a seria...

Page 18: ...tems as shown in Figure 18 Note that certain items are disabled grayed out if the GUI is NOT in communication with the HR 4P unit Reset Unit Reset your HR 4P unit after a new I O configuration or IR c...

Page 19: ...D and LINEFEED 0x0A Characters Each command is terminated by a single CARRIAGE RETURN cr Command Function Response VER cr Read Firmware version Version x y cr lf where X Y is the firmware version ADR...

Page 20: ...cr lf FDFT cr Factory default Are you sure Y N User must send CAPITOL Y before 8 Second Timeout RST cr Unit Reset Restart CMDn cr Set serial command format n S L short long status ACK Character CMD R...

Page 21: ...ework 2 0 minimum has been installed COMMUNICATIONS PROBLEMS WITH GUI Set switch to PRG position when using the GUI The LED should be BLINKING Ensure RS232 cable used is compatible with the PC being u...

Page 22: ...lete description 5 2 Shipping and Packaging If you need to transport or ship your unit Package it carefully We recommend that you use the original container Before you ship the units back to Hall Rese...

Page 23: ......

Page 24: ...ved Order toll free in the U S 800 959 6439 FREE technical support Call 714 641 6607 or fax 714 641 6698 Mail order Hall Research 1163 Warner Ave Tustin CA 92780 Web site www hallresearch com E mail i...

Reviews: