background image

  

 

Genesis Digital™ HDMI Matrix Switches 

19

 

 

Factory Default Settings for IP interface 

Field 

Value 

GUI Tab 

Power 

Off 

Routing 

INPUT1 

HDMI_In_1 

Labels 

INPUT2 

HDMI_In_2 

Labels 

INPUT3 

HDMI_In_3 

Labels 

INPUT4 

HDMI_In_4 

Labels 

OUTPUT1 

HDMI_Out_1 

Labels 

OUTPUT2 

HDMI_Out_2 

Labels 

OUTPUT3 

HDMI_Out_3 

Labels 

OUTPUT4 

HDMI_Out_4 

Labels 

PRESET1 

PRESET_1 

Labels 

PRESET2 

PRESET_2 

Labels 

PRESET3 

PRESET_3 

Labels 

PERSET4 

PRESET_4 

Labels 

PRESET5 

PRESET_5 

Labels 

PRESET6 

PRESET_6 

Labels 

PRESET7 

PRESET_7 

Labels 

PRESET8 

PRESET_8 

Labels 

Name 

HSM Matrix 

Settings 

Location 

Hall Research 

Settings 

IP 

Assigned by 

DHCP 

Settings 

Subnet 

Based on IP 

Settings 

Gateway 

Assigned by 

DHCP 

Settings 

DHCP 

Enabled 

Settings 

Login 

Disabled 

Settings 

Telnet 

Enabled 

Settings 

Default 

P

pass 

Settings 

 

DHCP 
Enables/ Disables DHCP. If enabled, the matrix is assigned an IP address from the 

user’s compatible networks DHCP router. This is the factory default. If disabled, the 

matrix is assigned the IP address, subnet mask and gateway address supplied by the 

user. 

Login 
Enables/Disables the system login password. If enabled, the matrix will require a 

password in order to operate the controls. If disabled, the matrix requires no password 

to operate the controls. This is the factory default. 

Telnet 
Enables/Disables the telnet interface. See Section 6 for more details 

 

Change Password? 
Allow the user to change the existing system password.  When clicked, a window will 

open for entering the new password. The password length is limited to eight (8) 

characters long.  

Apply 
The User must click this button 

after changing any field on 

settings tab to save the changes.  

Factory Reset 
This button restores the factory 

defaults to this matrix. Factory 

default will also wipe out saved 

presets.  

Summary of Contents for Genesis Digital HSM-04-04

Page 1: ...92780 Web site www hallresearch com E mail info hallresearch com CUSTOMER SUPPORT INFORMATION User s Manual Genesis Digital HDMI DVI Matrix Switch Series HSM 04 04 4x4 HDMI Matrix Switch with RS 232 H...

Page 2: ......

Page 3: ...e interference to radio communication It has been designed to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules which are...

Page 4: ...aving Presets routing patterns 10 3 6 Recalling Presets routing patterns 10 4 Control Commands RS 232 and IP 11 4 1 Routing Functions 11 4 2 Preset Save and Recall Functions 12 4 3 Power Functions 12...

Page 5: ...ndependently for each output This assures that the highest numbers of colors possible are displayed on each output In other words if some outputs are connected to displays that only support HDMI 1 2 a...

Page 6: ...ternal EDID emulation user selection option Output video signals are de skewed and recreated with perfect timing and are jitter free Includes IR remote control Front panel IR sensor and rear panel con...

Page 7: ...anual Figure 1 Power Supply and IR Remote 2 2 Input and Output Connections The matrix is housed in a 1RU 19 wide rack mountable enclosure All of I O control and the power connections are on the rear o...

Page 8: ...ith screws and stand offs for securing the cables in place so they don t accidentally get unplugged Figure 4 Model C HDMI L x x 1 5 3 6 10 15 25 35 or 50 ft Next connect the HDMI outputs to the displa...

Page 9: ...through DB9 MF cable Table 1 RS 232 Control Port Pin out The HSM matrices are available with IP network port HSM I On these units there is an RJ45 10 100 Base T for connection to your Local Area Netwo...

Page 10: ...s Save preset patterns All of the front panel switches have built in LEDs that help in the operation Front panel functions are designed for maximum intuitiveness With just a little practice one can ea...

Page 11: ...down buttons to walk through other outputs or just select another output channel To route the output to a different input than the one currently connected to hit the candidate input channel number Thi...

Page 12: ...e same as the total of input and output buttons Therefore each front panel button can memorize a pattern For a 4x4 matrix you can recall 8 presets and for a 4x2 you can recall 6 presets However throug...

Page 13: ...do not come equipped with a serial RS 232 port Therefore for serial control from a PC you may need a USB to RS 232 converter These are available from Hall Research Model USB RS232 1 Figure 9 USB to R...

Page 14: ...onse None the current tie pattern is saved in EEPROM 4 3 Power Functions Command PW1 cr stands for Power On Response PW1 space cr CO1 m1 cr CO2 m2 cr CO3 m3 cr Only for 4x4 matrices CO4 m4 cr Only for...

Page 15: ...t 128 bytes of EDID table correspond to Hall Research canned emulation in which most standard PC both 4x3 and 16x9 resolutions are reported to all the inputs This mode should be used if your inputs ar...

Page 16: ...he matrix can be controlled via RS232 Serial port or through an IP Ethernet port if equipped The IP interface features a built in web server allowing web browsers running on different devices computer...

Page 17: ...unning on any device Computer Smart phone iPad on the same network can use this interface When the matrix is shipped it is configured with a dynamic IP address and when powered up on a compatible netw...

Page 18: ...ble disable password protected login or change the IP configuration etc The Preset Input and Output names are saved permanently in matrix until the user changes them The matrix will also remember the...

Page 19: ...nput to tie to the respective matrix output The also shows the current tie status and is updated in real time Recall Preset Previously saved ties may be saved in the matrix and can be recalled for qui...

Page 20: ...ry default settings whenever necessary Name User defined name for this matrix The name can be sixteen 16 characters including any white space and special characters Location User defined location of t...

Page 21: ...P Enables Disables DHCP If enabled the matrix is assigned an IP address from the user s compatible networks DHCP router This is the factory default If disabled the matrix is assigned the IP address su...

Page 22: ...Y Address is not valid WAIT until you see following Welcome message on Screen It confirms that device has done with applying settings and serial interface is ready for other commands Welcome to Hall R...

Page 23: ...configuration To use this interface the user must open a TCP socket connection on port 6324 using a compatible telnet client to communicate with matrix Figure 16 shows an example of using the PUTTY c...

Page 24: ...tempt to repair the unit instead contact Hall Research Technical Support at 714 641 6607 Before you do make a record of the history of the problem We will be able to provide more efficient and accurat...

Page 25: ...PCM2 PCM5 1 PCM7 1 Dolby5 1 DTS5 1 DD D TrueHD DTS HD General Power Supply 100 VAC to 240 VAC 50 60 Hz external 5 VDC 6 A regulated Nominal Power Fully loaded 17 watts max 3 4 amps 5v Temperature hum...

Page 26: ...n on hit power button To turn off Press and hold power button Appendix 2 Command Summary Command Function PWx Power on off x 0 power off 1 power on Omitting x will show current power status COn m Conn...

Page 27: ......

Page 28: ...ved Order toll free in the U S 800 959 6439 FREE technical support Call 714 641 6607 or fax 714 641 6698 Mail order Hall Research 1163 Warner Ave Tustin CA 92780 Web site www hallresearch com E mail i...

Reviews: