Safetybox 400 is an automatic switch-off device monitoring the operation of electrical appliances. It stops them being operated when the front/door 

is shut.  A button activates the monitoring function. Suitably position the button on the piece of furniture to ensure that the front/door is always 

open to a sufficient degree.

The Safetybox has a 5-strand main flex and a 5-strand appliance cord with free ends for connecting 400V~ or 230V/240V~ electrical appliances as 

undertaken by authorised electrical personnel. A 400V~ connection allows el. appliances with a power consumption of up to 6000VA to be operated 

at the Safetybox. Given the connection of 230/240V~ el. appliances, a max. 3600VA can then be tapped by way of each of the 3 phases.

The Safetybox must be fused at 16A per phase via the domestic electrical installation.

  

Important Safety Information

•   Damage caused by incorrect connection will invalidate warranty entitlement and acceptance of consequential damage to connected devices.

•   Only approved door push button/magnetic switch may be used in the accessories.

•   The connection to the electrical grid must be performed only by a qualified professional electrician who knows the local regulations and the 

     supplementary regulations of the local electric utilities accurate and adhere carefully. Improper installation and maintenance work or repairs 

     considerable danger to the user may arise, for which no liability is accepted.

•   During installation, maintenance and repairs the safety box must be completely disconnected from the mains electricity supply. Off this purpose,

     all supply circuits and secure against reconnection. Make it sure for example this: - switch off the fuses of the electrical installation or - unscrew

     the screw type of electrical installation.

•   The safety box must not be installed in locations where the ambient temperature is increased by other devices. The preset distances for installation 

     must be observed. The installation position must allow air to circulate.

•   When it´s external flexible cable is damaged, it must be replaced exclusively by the manufacturer or his customer service.

•   No warranty cover if unauthorized changes to approved safety box and door push button/magnetic switch.

Function 

The Safetybox individually monitors each of the three phases. The Safetybox emits a 90-second whistle as a warning if during a phase more than 

115VA at 230V~ or 200VA is tapped and 400V~ respectively should no door push button/magnetic switch enabling be on hand. Failure to correct 

the position of the door/front during this time results in all phases being simultaneously shut down.

The Safetybox switches all the phases back on once door button enabling has taken place.

Technical Data

Subject to technical alterations !

Assembly and Installation

•   Disconnect all inputs and protect against reconnection-observe safety instructions.

•   Install the door push button/magnetic switch switch box at a suitable location on the furniture so that it ensures that the front / door is always 

     open sufficiently. Lay line for safety box so that is not burdened on train.

•   The safety box has to be mounted at a suitable location. The environment must not be allowed to warm more than 35°C. An appropriate distance to 

     external heat source (eg oven) is observed. The distances for the installation shown in Figure XX must be observed. The installation position must 

     allow air to circulate.

•   Door push button/magnetic switch on connector to connect safety box. Line so embarrassed that connector is not charged on train. 

     Note: When the switch is not connected correctly recognizes the safety box permanently a malfunction.

•   Let the connection of the E-units in accordance with manufacturer - specified correctly. Use only approved electrical equipment for distribution 

     when connecting several e-devices. The stated power limits must not be exceeded.

•   The power cable must be connected properly. Connection conditions 3 phases/N/PE

•   The power supply must be protected by 16A per phase. It must always be connected to phase L1. About L1 the internal control of the timer is 

     receiving power. If L1 is not connected all outputs are without power.

en  

Mains voltage :                                                                         230 - 240V~                                            400V ~ 

 Power frequency:                                                                                                       50/60Hz 

Rated current :                                                                                                          max. 16A ~ 
Fusing via domestic electrical installation required                     16A fuse                                                 16A fuse 
Total switching capacity : (cos Phi =1)                             max. 3680VA per phase                                  max. 6000VA 

 Switching threshold                                                                100 -115VA                                             175 -200VA 
 Power consumption                                                                                                       4.8W 

ON-time at rated input                                                                                                  100 % 
Switching cycles                                                                                                          100x10³ 
Ambient temperature                                                                                                   max. 35°C 
Safety class                                                                  Safetybox  - Safety Class I  

E

 

                             

Door push button/magnetic switch - 5V safety extra-low voltage Safety Class III   

3

 

Degree of protection                                                      IP 20 /  

Housing (L x B x H)                                                        188 x 11x70 
Mains supply lead                                                          2.5m lead H05VV-F 5*2.5mm², white, free ends 
Appliance cord                                                               2.5m lead H05VV-F 5*2.5mm², white, free ends 
Installation / Safety pointer                                            Connection only by a qualified electrician in keeping with the national 

                                                                                      requirements in force and with attention paid to the manufacturer's 

                                                                                      electrical appliance specifications  

Safetybox ASA400, 240V~/400V3N~, 16A

Summary of Contents for Safetybox ASA400

Page 1: ...chtigen Veränderungen an Safetybox und zugelassenem Original Taster Funktion Die Safetybox überwacht jede der drei Phasen einzeln Wird bei nicht Freigabe durch den Türtaster Magnetschalter auf einer Phase eine Leistung von mehr als 115VA bei 230V bzw 200VA bei 400V abgenommen warnt die Safetybox 90 Sekunden lang mit einem piependen Signalton Wird in dieser Zeit nicht die Position der Tür Front kor...

Page 2: ...an 115VA at 230V or 200VA is tapped and 400V respectively should no door push button magnetic switch enabling be on hand Failure to correct the position of the door front during this time results in all phases being simultaneously shut down The Safetybox switches all the phases back on once door button enabling has taken place Technical Data Subject to technical alterations Assembly and Installati...

Page 3: ... button magnetic switch Mounting assembly of door push magnetic switch according to specific assembly instruction Montage Türtaster Magnetschalter nach Herstellervorgabe Halemeier GmbH Co KG Lange Straße 51 D 49326 Melle Neuenkirchen 19 713 20 01 04 2015 IP20 cMMqK m Safetybox ASA400 240V 400V3N 16A ...

Page 4: ...stimmungen zur Abfallbeseitigung Recycling erfolgen en A disposal on domestic waste is not permitted A disposal must be according the public requirements of waste disposal recycling m Halemeier GmbH Co KG Lange Straße 51 D 49326 Melle Neuenkirchen 19 713 20 01 04 2015 m MqK cM IP20 Safetybox ASA400 240V 400V3N 16A ...

Page 5: ...u grey 16A schwarz black F12 braun brown blau blue Safetybox ASA 400 Safetybox ASA 400 Safetybox ASA 400 L3 MP N L2 L1 L3 L2 MP L1 N Verbindungsdose Abzweigdosen Junction box junction boxes Kochfeld hob Kochfeld hob 3x230 240VAC Mikrowelle microwave oven 1x 230 240 VAC Backofen oven 1x 230 240 VAC Wärmeplatte hot plate 1x 230 240 VAC 3x400VAC 1x 230 240 VAC Backofen oven 1x 230 240 VAC Wärmeplatte...

Reviews: