Page
44
SmartFOAM
Figure 24
: In-Line Strainer Mounting Bracket
3. Secure the bracket and strainer/valve assembly
to the apparatus.
4. Select the appropriate fittings from the bag
attached to the strainer assembly. Two of each
fitting are included with the strainer assembly.
For fitting selection vs. type of foam concentrate
(see Figure 23
5. Coat all fitting threads with Permatex #80724 (or
equal) plastic pipe thread sealant. Install the
fittings into the strainer/valve assembly ends and
tighten.
6. Install the clear plastic hose from the foam tank
outlet to the inlet of the strainer/valve assembly.
(Figure 23
: In-Line Strainer/Valve Installation
).
Wet the ends of the hose and fittings to make
the installation easier.
CAUTION!
MAKE SURE THE FOAM TANK AND FOAM
CONCENTRATE SUCTION HOSES ARE CLEAN
BEFORE MAKING FINAL CONNECTION TO FOAM
PUMP. IF NECESSARY, FLUSH THE TANK AND
HOSES PRIOR TO MAKING THE CONNECTION.
7. Install the clear plastic hose from the in-line
strainer/valve assembly outlet to the inlet of the
Hale MDT II, Hale MST, foam concentrate
pump, or the correct fitting on Hale ADT.
FS SERIES STRAINER
When a pressurized water flush is provided to the
strainer from one of the discharges, Hale FS series
strainers are required. The plumbing exposed to the
flush water pressure must be rated at or above the
operating pressure of all other discharge plumbing
components (500 PSI/34 BAR minimum).
To Install FS Series Strainers
1. Choose a location on the apparatus that allows
gravity feed from the foam tank to the strainer
inlet and from the strainer outlet to the foam
pump suction connection.
2. When selecting the strainer location make sure
there is sufficient space behind the pump panel
to attach hoses and fittings. Also make sure the
inlet connection port is oriented correctly. (See
Figure 25
Figure 25
: FS Strainer Orientation
3. Remove the strainer cap, mounting screws and
nameplate from the strainer assembly.
4. Mark holes for mounting the foam strainer by
using the nameplate as a guide, or see Figure
26
: FS Strainer Mounting Dimensions
5. Select the appropriate fittings to attach the
hoses to the strainer. Two of each fitting are
included with the strainer assembly. The fittings
and hoses must be capable of withstanding the
vacuum generated by the foam pump (23 inches
[584 mm] Hg) and the maximum flushing water
pressure (500 PSI [34 BAR]).
6. For FS-
15 strainers use 3/4” (19mm) NPT x 3/4”
hose fittings. For FS-
25 strainers use 1” (25mm)
NPT x 1” hose fittings.
7. Coat all fitting threads with a suitable thread
sealant. DO NO USE Teflon Tape. Install the
fittings into the strainer/valve assembly ends and
tighten.
Summary of Contents for SmartFOAM 1.7AHP
Page 3: ...Page 2 SmartFOAM NOTES...
Page 14: ...Page 13 SmartFOAM Figure 2 3 3 and 5 0 Foam Pump Installation Envelope Dimensions...
Page 15: ...Page 14 SmartFOAM SYSTEM DIAGRAM Figure 3 Typical Hale SmartFOAM 2 1A and 1 7AHP System...
Page 16: ...Page 15 SmartFOAM Figure 4 SmartFOAM 3 3 5 0 6 5 Single Tank System with In line Strainer...
Page 17: ...Page 16 SmartFOAM Figure 5 SmartFOAM 3 3 5 0 6 5 Single Tank withMSTandIn lineStrainer...
Page 18: ...Page 17 SmartFOAM Figure 6 SmartFOAM 3 3 5 0 6 5 Single Tank withMSTandFSSeriesStrainer...
Page 19: ...Page 18 SmartFOAM Figure 7 SmartFOAM 3 3 5 0 6 5 Dual Tank withMDTIIandIn lineStrainer...
Page 20: ...Page 19 SmartFOAM Figure 8 SmartFOAM 3 3 5 0 6 5 Dual Tank withMDTIIandFSSeriesStrainer...
Page 21: ...Page 20 SmartFOAM Figure 9 SmartFOAM 3 3 5 0 6 5 Dual Tank with ADTandIn lineStrainer...
Page 22: ...Page 21 SmartFOAM Figure 10 SmartFOAM 3 3 5 0 6 5 Dual Tank with ADTandFSSeriesStrainer...
Page 40: ...Page 39 SmartFOAM Figure 18 Typical 4 Inch Check Valve Installation Midship Pump...
Page 51: ...Page 50 SmartFOAM Figure 33 ADT Option Air Hose Connections Part 2...
Page 68: ...Page 67 SmartFOAM NOTES...
Page 80: ...79 Page 79 SmartFOAM NOTES...