2
FOR MORE INFO REFERENCE OIM MANUAL P/N FSG–MNL–00210
ONLY TOUCH THE SCREEN IN ONE PLACE AT A TIME. THE TOUCHSCREENS DO NOT SUPPORT
MULTI–TOUCH.
Figure 1.
SAM Control Center (Left) And Pump Controller (Right)
2.1
Additional SAM Interfaces
IN AN EMERGENCY, pressing the IDLE button (Figure 2) on the twister will send the engine to idle, place SAM
in Manual mode, and the governor to IDLE mode. NOTES: Touching the mode button (IDLE – greyed out)
places the governor in PSI mode. Also, the throttle portion of the twister is limited while SAM is in Auto Mode
(momentary 10 PSI or 100 RPM change – overwritten in 1 second by auto mode).
The ITL–40 provides continuous display of the onboard water level. Additionally, the SAM Control Center dis-
plays the onboard water level with color indications (yellow bars for low water warning).
Figure 2.
Twister Throttle Controller And ITL–40
Optionally, the apparatus may have up to two additional SAM Control Centers to provide SAM operation from
curb side or other location. Collocated with each additional Center is a remoted emergency IDLE button.
2.2
Entering Manual Operation
Manual mode can be accessed at any time, even before the pump is placed in gear. The default SAM Control
Center splash screen (shown on left, see Figure 3) displays until the pump is engaged.
Once the pump is engaged, SAM goes into Auto Mode (shown on right, see Figure 3).
Summary of Contents for SAM GENERATION 2
Page 2: ......