Step 1
STEP 1
Remove light housing from niche.
Make sure power to the pool is tuned off at the circuit breaker. Carefully remove
the existing light house from the niche assembly and place it on the pool deck.
There should be enough power cord to do this easily. If there is not enough power
cord to allow the light housing to reach the pool deck surface, call your local pool
STEP 2
Remove old lamp.
Access the old lamp according to the original manufacturer’s pool light installation
manual. Remove the screws and/or loosen the clamp that holds the face plate and
lens in place. Carefully remove the lens from the pool light housing. Take care
not to damage the surface of the light housing body that makes contact with the
rubber gasket.
STEP 3
Inspect your light housing for signs of wear.
Inspect the rubber grommet where the power cord enters the light for excessive
deterioration. Inspect the light housing, the tensioning clamp, and face ring for
warping, dents and excessive rust. Do not install Halco ProLED
®
White LED Lamp
into a pool light housing that appears to be worn out.
STEP 4
Dry the light housing and lens.
Make sure the inside of the light housing and glass lens are completely dry by wiping
them down with a clean rag.
STEP 5
Install Halco ProLED
®
White LED lamp.
Remove the old lamp and discard. Carefully screw the Halco ProLED
®
White LED
lamp into the socket.
WARNING
Failure to install a new lens gasket could result in water leakage which can
permanently damage the Halco ProLED
®
White LED lamp and cause serious
injury or death due to electrical shock.
ALWAYS USE A NEW LENS GASKET WHENEVER REASSEMBLING YOUR POOL LIGHT HOUSING.
STEP 6
Reassemble the light housing.
Proceed by cleaning any gasket residue from the light housing body. A clean
surface is necessary for the new gasket to seat properly and prevent leakage. Install
the new gasket onto the glass lens.
The product warranty is voided if the proper gasket is not installed. See the “Gasket
Compatibility” section for details.
Set the lens and faceplate in the light housing and re-assemble according to the
light housing manufacturer’s specification. Tighten the screws or clamp slightly,
allowing the gasket to seal evenly.
Pool Deck Surface
To GFCI, Circuit
Breaker and Power
Source
The niche assembly
WARNING
VERIFY THAT YOUR HALCO ProLED
®
WHITE LED LAMP VOLTAGE RATING (120VAC
OR 12VAC) MATCHES YOUR ELECTRICAL SYSTEM’S VOLTAGE REQUIREMENTS
BEFORE PROCEEDING WITH INSTALLATION.
Figure 3:
Step 2-4
STEP 7
Submerge assembled light into the water.
Once the screws or clamp are tight, submerge the assembled light
housing in the water and visually check that air bubbles are not escaping
from the gasket area. Should bubbles appear, immediately remove the
light housing from the water and reset the gasket and lens.Once you are
satisfied that there are no air leaks, complete the installation by wrapping
the cord around the light housing and re-attaching the light housing to the nice