7. PARTS LIST
●
HAKKO FA-430
Pre-filter
Main filter
Cap
Knob
Power switch
Power cord, 3 wired cord but no plug
Power cord, 3 wired cord & BS plug
Power cord, 3 wired cord& European plug
Power cord, 3 wired cord & BS plug
Power cord, 3 wired cord & Australian plug
Power cord, 3 wired cord & Chinese plug
Power cord, 3 wired cord & American plug
Power cord, 3 wired cord & SI plug
Power cord, 3 wired cord & BR plug
1
2
3
4
5
6
A1572
A1573
B3619
B1486
B2852
B2421
B2422
B2424
B2425
B2426
B2436
B3508
B3550
B3616
Part No.
Part Name
Specifications
Item No.
Specifications
●
Nothing happens when the power switch
is turned on.
●
Orange lamp keeps flashing after replacing
the pre-filter.
●
Red lamp is flashing for 5 seconds just
after turning the power switch on.
●
Red lamp keeps flashing after replacing
the main filter.
●
Red lamp lights up.
●
All lamp flashes at the same time.
Is the power cord disconnected ?
Connect it.
Is the main filter set properly ?
Fit the main filter properly before turning
on the power switch again.
Is the flow control set to RESET ?
Adjust the flow suitable for working
environment by using the flow
selection switch.
When replacing the filter, Is the flow
selection switch adjusted to RESET with
the power switch on ?
Make sure that power switch is ON,
and set the flow selection switch to
RESET again.
When replacing the filter, Is the flow
selection switch adjusted to RESET with
the power switch on?
Make sure that power switch is on
and set the flow selection switch to RESET.
Lift the main filter more than 3 seconds.
Main filter needs to be replaced.
Recommend replacing the main filter
otherwise performance
will be reduced.
Main filter has exceeded its service life
and was never replaced. It has passed
more than 2500 hours since it is used.
Main filter must be replaced. Failure to do
so may result in damage to the unit.
Contact your HAKKO representative
because it is necessary to repair the
main unit.
1
2
10
5
7
4
3
6
3
4
9
9
8
11
●
Option
Duct set /
Rectangular nozzle
Duct set /
Round nozzle
Duct
Adapter
Adapter
Rectangular nozzle
Round nozzle
Bench top hood
Net
Duct
Duct band
Duct (1) / Adapter (1)
Rectangular nozzle(1) / Net (1)
Duct (1) / Adapter (1)
Round nozzle (1) / Net (1)
φ 55 mm
For 3 inch
5 pcs.
For 3 inch (φ 75 mm)
Set of 2
C1571
C1572
B3642
B3620
B3621
B3622
B3623
B2418
B3625
B2410
B2416
10
11
Item No. Part No.
Part Name
1
2
3
4
5
6
7
8
9
7. PARTS LIST
6. TROUBLE SHOOTING GUIDE
5. MAINTENANCE
Performing proper and periodic maintenance extends the product life. Wear of the product will
differ depending on work environment, the quality and quantity of the solder and flux.
Apply the following service procedure as dictated by the conditions of the usage.
●
How to replace the filter
●
The lamp status indicates appropriate time to replace the main filter and pre-filter.
If continuing to use the main filter or pre-filter after the lamp status indicates it is time for
replacement, it may result in reduced performance and/or subsequent damage to the unit.
A. Pre-filter
●
In case of replacing the pre-filter only with the red and orange lamp flashing.
B. Main filter
*If not replacing the main filter after the lamp indicated to replace it, the red lamp
will flash for 5 seconds every time the power switch is turned on.
●
When replacing the filter, set the flow selection switch to RESET
without turning off the power switch.
Pre-filter lamp (orange) flashes.
Set the flow selection switch to RESET with the power switch on. (The fan will stop.)
Open the upper cover and remove the pre-filter only. Fit the new pre-filter on top of the main filter
so that it lies flat with no gaps, then close the upper cover.
Set the flow selection switch back to the previous position.
The fan will start running and the unit will return to a normal operating condition.
Pre-filter : 80% of the pre-filter is clogged or it was used for 200 hours. (The orange lamp flashes.)
Pre-filter lamp (orange) and main filter lamp (red) flash.
Set the flow selection switch to RESET with the power switch on. (The fan will stop.)
Open the upper cover and then remove the pre-filter only. Fit the new pre-filter on top of the
main filter so that it lies flat with no gaps, then close the upper cover.
Set the flow selection switch back to the previous position.
After 5 seconds are passed, the red lamp will be turned off.
1
2
3
4
Turning on the power
After
5 seconds
MAIN
POWER
PRE
MAIN
POWER
PRE
After
5 seconds
MAIN
PRE
POWER
MAIN
POWER
PRE
MAIN
POWER
PRE
MAIN
POWER
PRE
MAIN
POWER
PRE
MAIN
POWER
PRE
MAIN
PRE
POWER
MAIN
POWER
PRE
1
2
3
4
Pre-filter lamp (orange) and main filter lamp (red) flash.
Set the flow selection switch to RESET with the power switch on. (The fan will stop.)
Open the upper cover and then remove both main filter and pre-filter.
Replace the filters with the new filters, fit them in the main unit and close the upper cover.
Set the flow selection switch back to the previous position.
The fan will start running and the unit will return to a normal operating condition.
1
2
3
4
MAIN
POWER
PRE
MAIN
POWER
PRE
MAIN
POWER
PRE
Flashing
Lighting
OFF
Do not lift the main filter when replacing the pre-filter.If the main filter is lifted for more than
3 seconds with the power switch on and the flow control set to RESET,
the used number of the pre-filter are reset to zero.
●
Filter replacement timing
Main filter : When the 10th pre-filter needs replacing. (The orange and red lamp flash.)
Replacing the filter without following the procedure will disrupt the timing for filter replacement
and may cause the overuse of the filters and subsequent damage to the unit.
10 pcs.
HAKKO FA-430 counts used number of the pre-filter in order to determine the
remaining life of the main filter. There are a few points to observe when replacing filters.
Read “How to replace the filter” and follow the procedure.
Replacing the filter without following the procedure may cause the overuse
of the main filter and subsequent damage to the unit.
220 - 240V
India
220V KTL , 230V CE
230V CE , U.K.
China