45
Maintenance and Care
5.4.1 Low Discharge Signal Sender
Fig.11
The factory setting is as fol-
lows:
tray battery 420 Ah EPzS.
5.4.2 Battery Charging Status
Indicator
Upon turning ON by key switch, battery
charging status is shown by display of
green bars (Fig. 11/1). As the battery
discharge during operation, the lighting
green bars extingguish one after anoth-
er showing thus always the current
charge status of battery charge.
Flashing of the last two green bars (Fig.
11/3) indicates that operation will be
stopped soon. In order to preclude low
discharge of batteries, the sweeping
units are switched off and riding speed
reduced to 50% if battery is dischrage.
The red LED (Fig. 11/4) than flashes
5.4.3
Hourmeter
The operating hours of the machine ap-
pear in the display (Fig. 11/2); the hour-
meter will count only during working or
transport ride; only full hours are dis-
played.
5.4.4
Setting Other Battery Types
Have the low discharge signal
sender set to other battery
types by qualified personnel
only and in approved qualified
workstations only.
2
1
3
4