10. PARTS LIST

Item No.

1

2

3

Part No.

B5002
B5003
B5004
B5005
B2403
B3011
B2987

Part Name

P.W.B
Transformer
Transformer
Transformer
Fuse/250V-2A
Fuse/250V-2A
Fuse/250V-1A

Specifications

100 - 110V
120V
220 - 240V
100 - 110V
120V
220 - 240V

● 

HAKKO FX-100 Starion

Item No.

1
2
3
4

Part No.

A1559
B5009
B3751
A1561

Part Name

Cleaning sponge
Iron holder base / Blue-yellow
Bottom plate
Cleaning wire

Specifications

with rubber foot

with Protective Sheet & rubber foot

● 

Iron Holder Parts

Part No.

B5006
B5007
B5008

FX1001-51

B2300

FH800-51BY

Part Name

Sleeve / Yellow
Sleeve / Green
Sleeve / Gray
HAKKO FX-1001
Heat resistand pad
HAKKO FH-800

Specifications

 

HAKKO FX-1001

FX-100

1

4

4

2

4

5

6

3

1

1

2

2

3

3

Item No.

1
2
3
4
5
6

● 

Optional Parts

Part No.

B3474

Part Name

Rubber cleaner

Specifications

Item No.

4

Part No.

B2419
B2421
B2422
B2424
B2425
B2426
B2436
B3508
B3550

Part Name

Power cord, 3-wire

cord & American plug

Power cord, 3-wire

cord but no plug

Power cord, 3-wire

cord & BS plug

Power cord, 3-wire

cord & European plug

Power cord, 3-wire

cord & BS plug

Power cord, 3-wire

cord & Australian plug

Power cord, 3-wire

cord & Chinese plug

Power cord, 3-wire

cord & American plug (B)

Power cord, 3-wire

cord & SI plug

Specifications

120V USA

India
220V KTL 230V CE
230V CE

China

Summary of Contents for FX-100

Page 1: ...tion as measures to protect the device to be soldered from the effects of static electricity Be sure to observe the following instructions 1 The handle and other plastic parts are not insulators they are conductors When replacing parts or repairing take sufficient care not to expose live electrical parts or damage insulation materials 2 Be sure to ground the unit during use Specifications and desi...

Page 2: ...e appliance Cleaning and user maintenance shall not be made by children without supervision Do not use the HAKKO FX 100 for applications other than soldering Do not allow the HAKKO FX 100 to become wet or use it when hands are wet Do not modify the HAKKO FX 100 Use only genuine HAKKO replacement parts Be sure to hold the plug when inserting or removing the iron cord Do not strike the iron against ...

Page 3: ...ld the head part of the T31 series tip not included with the heat resistant pad and insert the tip into the handpiece Push until the tip stops C Station 1 Insert the power cord into the receptacle at the back of the station 2 Insert the connection cable plug into the receptacle at the front of the station and turn it in a clockwise direction until it stops 3 Set the iron in the iron holder 4 Plug ...

Page 4: ...arts falling as the iron tip approaches stable temperature reaching the minimum when the stable temperature is achieved Start soldering after the stable temperature is reached Example MODE screen NORMAL BOOST CANCEL OK Operate the machine using these buttons that are placed in the order of the buttons displayed on the screen When MODE is pressed The mode can be changed to NORMAL mode or BOOST mode...

Page 5: ... No 1 or No 2 can be selected SHOW PROFILE SHOW TIP LOADS SHOW TIP TIME OK The cursor moves by pressing the or button The following items are displayed in order SHOW PROFILE SHOW TIP LOADS SHOW TIP TIME SELECT PROFILE TIP TYPE CANCEL PEOFILE 1 STATION ID USER NAME SOLDER TYPE PEOFILE 1 S U S TIP LOADS approx xxxxxx points RESET OK Really RESET OK CANCEL OK When RESET is selected Really RESET OK CA...

Page 6: ...etting change is reflected by selecting SAVE OK To escape without setting change select CANCEL パスワードロックの設定を行なっている場合 SET画面へ移行する前にパスワードの入力が必要となります Display in the AUTO DETECT mode when T31 01 is selected 01 N DISPLAY AUTO SLEEP AUTO SHUTOFF OK The cursor moves by pressing the or button The following items are displayed in order DISPLAY AUTO SLEEP AUTO SHUTOFF PASSWORD LOCK PROFILE ALERT TIME SAVE CAN...

Page 7: ... set up When the SHUT OFF time is set the power supply stops when the soldering iron is not used for the set period of time even though the soldering iron is not placed on the stand DISPLAY The fashion in which the output graph is displayed can be changed NORMAL Histogram rolling bar graph EXPAND Horizontal expanding graph OFF No display AUTO SLEEP The automatic sleep period can be set up Sleep fu...

Page 8: ...e tip and reset the TIP TIME from the DSP menu See 5 How to Use SHOW TIP TIME PROFILE画面 When STATION ID is selected STATION ID PROFILE 1 PROFILE 2 OK USER NAME SOLDER TYPE CANCEL OK When PROFILE1 2 is selected STATION ID OK When SOLDER TYPE is selected PROF 1 SOLDER OK When USER NAME is selected PROF 1 USER OK You can make your name and ID from A Z 0 9 and space You can enter up to 14 letters This...

Page 9: ...tch OFF and disconnect the power plug before performing any maintenance procedure Replacing the fuse 1 Unplug the power cord from the power receptacle 2 Remove the fuse holder 3 Replace the fuse 4 Put the fuse holder back in place The port on the back of the station is used to display heater output on the external device not included The output displayed on the monitor can be displayed on an exter...

Page 10: ...0 51BY Part Name Sleeve Yellow Sleeve Green Sleeve Gray HAKKO FX 1001 Heat resistand pad HAKKO FH 800 Specifications HAKKO FX 1001 FX 100 1 4 4 2 4 5 6 3 1 1 2 2 3 3 Item No 1 2 3 4 5 6 Optional Parts Part No B3474 Part Name Rubber cleaner Specifications Item No 4 Part No B2419 B2421 B2422 B2424 B2425 B2426 B2436 B3508 B3550 Part Name Power cord 3 wire cord American plug Power cord 3 wire cord but...

Page 11: ... DEVELOPMENT CO LTD TEL 2811 5588 FAX 2590 0217 http www hakko com hk E mail info hakko com hk SINGAPORE HAKKO PRODUCTS PTE LTD TEL 6748 2277 FAX 6744 0033 http www hakko com sg E mail sales hakko com sg Please access to the following address for the other Sales affiliates http www hakko com HEAD OFFICE 4 5 Shiokusa 2 chome Naniwa ku Osaka 556 0024 JAPAN TEL 81 6 6561 3225 FAX 81 6 6561 8466 http ...