background image

OUT1

OUT2

AL1

AL2

COM

RDY

DI

MODE FUNC

▼ ▲

PV

SV

Controller

Preheat plate (L)

Power cord

1

1

1

PACKING LIST AND PART NAMES

1

1

Thermocouple

Instruction manual

WARNINGS AND CAUTIONS

Warnings and cautions are placed at critical points in this manual to 

direct the operator's attention to significant items. They are definedas 

follows.

WARNING :

CAUTION  :

Failure to comply with a WARNING may result 

inserious injury or death.

Failure to comply with a CAUTION may result in injury 

to the operator, or damage to the items involved.

CAUTION

When power is ON, the plate surface may be as hot as 500℉. To avoid 

injury or damage to personnel and items in the work area, observe the 

following :

Do not touch the plate or place metal parts near the plate.

Do not allow the plate to come close to, or touch, flammable materials.

Inform others in the area that the unit is hot and should not be 

touched.

Turn the power off when not in use, or left unattended.

This product is not intended for use by persons (including children)

with reduced physical, sensory or mental capabilities, or lack of

experience  and knowledge, unless they have been given supervision

or instruction concerning use of the product by a person responsible

or their safety.

Children should be supervised to ensure that they do not play with the

product.

Do not use the product for applications other than Preheat plate.

Do not allow the product to become wet, or use it with wet hands.

Remove power and controller cords by holding the plug - not the cord.

While using the product, don't do anything which may cause bodily

harm or physical damage.

SPECIFICATIONS

Output 
Power Consumption
Temperature Range 
Temperature Stability 
Dimensions (Large plate)

(Controller)

Size of plate
Weight (Without cord)

AC120V 60Hz 
600W (Large plate) 
0-500℉ 
±10℉
250(W)×79(H)×204(D)mm  (9.8×3.1×8.0 in)
100(W)×66(H)×169(D)mm  (3.9×2.6×6.7 in) 
178×178mm (Large plate)   (7.0×7.0 in) 
2.5kg (Large plate)    (5.5 lbs.) 
1.0kg (Controller)       (2.2 lbs.)

Controller
To use the controller to configure the preheat plate for use as follow.

Themocouple connector

Setting temperature

Toggle

switch

Plate temperature

Power switch

1. Turn the power switch ON.

2. Setting temperature is displayed as Set Variable (SV).    

Plate temperature is displayed as Process Variable (PV).    

The plate temperature rises to the setting temperature. 

3. When changing the setting temperature, press the “

”button    

 or “

”button to set the temperature.

4. Turn the power switch OFF after using.

*Toggle Switch

The controller has toggle switch to select between plate temperature 

control or T/C temperature control.

For T/C temperature control:
1. Insert thermocouple into thermocouple connector. Place the

thermocouple end on a desired temprature measuring point or

the item to be heated by the plate.

2. Switch toggle switch to T/C mode.

3. Temperature reading of the thermocouple is displayed as Process

Variable. Change the setting temperature as needed.

CAUTION 

When the thermocouple is attached, the temperature of the plate 

will rise until the T/C reaches to the setting temperature.  

Ensure the T/C is properly attached and not left in open air or 

damage may result.

Controller

Preheat plate

Power cord

Thermocouple

OPERATION

Instruction Manual

Thank you for purchasing the HAKKO FR-860 preheat plate.

Please read this manual before operating the Preheat plate.

Keep this manual readily accessible for reference.

PREHEAT PLATE

FR-860

Reviews: