IDE...S ErP • IND...S ErP
2. ACCESSORIES
When receiving the product, please, check the packaging for the following acces-
sories (1 pc of each one):
• Instructions for installation and use
• Guarantee document
• List of Service Stations
• Energy label
• Product information sheet
3.
PRINCIPLE OF OPERATION
Indirect (INDxxxS ErP) and indirect electrically heated (IDExxxS ErP) hot water
tanks can be operated using:
electricity, solar energy, gas, coal or other energy
sources. Closed system indirect (IND...) and indirect electrically heated (IDE...) hot
water tanks can supply hot water to one or more water withdrawing locations
within households or institutions. The hot water obtained is suitable for both
cleaning and drinking purposes. However, having regard to the fact that hot wa-
ter has a higher capacity to dissolve metals, it is recommended to use cold wa-
ter for cooking and drinking, and consume it after heating, when hot water is
needed. The water is of drinking water quality, if it complies with the limit values
laid down in Government Decree No. 201/2001 (X.25.). After reaching the facto-
ry set temperature, heating is automatically turned off by the temperature regu-
lator (for IDExxxS Erp types). Thus, hot water can be obtained from the storage
tank for a long time. The polyurethane heat insulation surrounding the inner tank
prevents the fast cooling of the water, thus ensuring the availability of hot water
from the container over a long time. Due to the design of the container, hot water
is discharged unmixed. The corrosion protection of the inner tank is ensured by a
special enamelling and active anodes. The enamelled design ensures long service
life, even in the case of aggressive waters.
4.
MOUNTING AND INSTALLATION OF THE TANK
The mounting (4) of the hot water tank, as well as its connection to
the water (5) and electrical network (6) and commissioning must be
performed by a qualifi ed professional according to our instructions and
observing the standards IEC 60364 / MSZ HD 60364.
In case of improper connection and installation,
you will lose all your guarantee and warranty
rights!
gépkönyv IND-IDExxxS ErP 1221114245-01.indd 20
2018.08.13. 11:45:56
Summary of Contents for IDE100S ErP
Page 101: ...3 101 Jegyzet gépkönyv IND IDExxxS ErP 1221114245 01 indd 101 2018 08 13 11 46 11 ...
Page 102: ...2 102 IDE S ErP IND S ErP gépkönyv IND IDExxxS ErP 1221114245 01 indd 102 2018 08 13 11 46 11 ...
Page 103: ...3 103 gépkönyv IND IDExxxS ErP 1221114245 01 indd 103 2018 08 13 11 46 12 ...