Memory & Apply Mode
1. Press "ON/OFF button" to turn on the light or off. 

2. To reset the parameters, Please follow the steps as below:
Step 1 - Press ON, to turn on the light if it was off at the start.
Step 2 - Press "Start" to the well-setting sensor.
Step 3 - Press the button of Detection range, Hold time, Stand-by dimming level, Stand-by period and Daylight threshold one aft

other in sequence.
Step 5 – Press “Memory” to memorize the settings.
Note: The interval of each parameter setting shall be controlled within 30s.

Isolated Setting Mode
1. Press "ON/OFF button" to turn on the light or off. Press "Auto Mode", the remote will activate settings that were saved last
remain at the factory default settings.

2. To reset the parameters, Please follow the steps as below:
Step 1 - Press ON, to turn on the light if it was off at the start.
Step 2- Press any button of "Auto Mode", “Reset” , Test" and "Apply" to begin the sensor detection mode. 
Step 3 - Press the button of Detection range, Hold time, Stand-by dimming level, Stand-by period and Daylight threshold one aft

other in sequence.

3. To programme other lights in the array that have similar sensors to the same programme.
Step 1 - Press "ON" to the second sensor
Step 2 - Press "Apply" 

Notes:

1. Settings will be saved automatically and remain until you press reset again.
2. Light will flicker when setting each parameter.

Summary of Contents for HD06VCRH 3

Page 1: ...ounted 2 4 6 8 10 12 14 16 Mounting height Wall Mounted 2 4 6 8 10 18 16 14 12 1 2 3 4 1 2 3 4 Covered Well covered Mounting height Detection area DIM 0 10V 10 20 30 50 Max ø14m 45 92ft ceiling mounted 15m 49 2ft ceiling mounted Operating voltage Operating current Output Stand by power Hold time Daylight threshold Stand by period Stand by dimming level 5 8GHz 75MHz 0 3mW Microwave frequency Microw...

Page 2: ...he module will be removed It doesn t hurt the looking of the whole pack Icon No icon The cover with humanoid icon indicates there is built in microwave module with sensor function The cover without humanoid icon indicates there is no built in module as well as sensor function Natural light Lux off Lux on light on automatically light off automatically Precondition of Daylight priority 2 Standby dim...

Page 3: ...and the present hold time elapsed light OFF With sufficient daylight even when motion detected light remains OFF With insufficient daylight when motion detected light ON After people leave the detection area light remains 100 brightness within hold time When motion is detected the sensor will switch on the light to 100 brighteness After the last detection and the present hold time elapsed light OF...

Page 4: ...n sunny days without the lampshade which will affect the tested lux value User Notes HD03R Reset Auto Mode Detection area Press to define detection area 100 75 50 25 Hold time Press to define holdtime 5s 30s 1min 3min 5min 10min 20min 30min Daylight threshold Press to define daylight level 2Lux 10Lux 30Lux 50Lux 80Lux 120Lux Disable Stand by period Press to define stand by period 0s 10s 30s 1min 5min ...

Page 5: ...ntrolled within 30s Isolated Setting Mode 1 Press ON OFF button to turn on the light or off Press Auto Mode the remote will activate settings that were saved last remain at the factory default settings 2 To reset the parameters Please follow the steps as below Step 1 Press ON to turn on the light if it was off at the start Step 2 Press any button of Auto Mode Reset Test and Apply to begin the sens...

Reviews: