Technical data

Supply voltage (see
rating plate)

230 VAC 50/60 Hz

115 VAC 50/60 Hz

24 VDC

allowable tolerance

+/- 5%

24-32 VDC

can be switched over by reconnecting wire
bridges

Fusing

160 mA medium lag

315 mA medium lag

1.6 A medium lag

Quiescent current in-
put

typically 40 mA

typically 80 mA

typically 60 mA

Type

FIW 202 E in the polycarbonate mounting en-
closure

Output data

2 solenoid valve outputs 24 VDC, output power
max. 24 W / 1 A

Pulse time

approx. 50 −  500 ms settable

Pause time

approx. 10 − 70 s settable

Enclosure material

Polycarbonate

Colour

RAL 7035 (light grey)

Installation

Wall-mounted

Degree of protection

IP65 to EN 60529

Dimensions (L × W × H)

120 × 75 × 200 mm

Weight

1.1 kg

Cable entries

3 × M16

Clamping areas of the cable entries

M16 for 4.0 − 8.0 mm

Connection cross-section

0.2 − 2.5 mm

2

Maximum surface temperature 

T

 of the enclos-

ure (category 3D) at 40 °C ambient temperature

80 °C

Allowable ambient temperature

Hazardous area Zone 22: Ta: -5 °C ... +40 °C

Outside the hazardous area: -20 °C ...+40 °C

Conformity

Low Voltage Directive 2014/35/EU (EN 60204-1)

Directive 2014/30/EU Electromagnetic Compat-
ibility (EN 61000-6-1, EN 61000-6-2, EN 55014-1)

Equipment marking

II 3D Ex tc IIIB T80 °C Dc X

IP65 Ta: - 5 °C ... + 40 °C

3 | Technical data

6

Electronic solenoid valve control · V1.0 · 04/2022

Operation manual

Summary of Contents for FIW 202

Page 1: ...Version V1 0 04 2022 Operation manual Electronic solenoid valve control FIW 202...

Page 2: ...e Filteranlagen GmbH An der Imb ke 7 27798 Hude Germany Tel 49 4408 8077 0 Fax 49 4408 8077 100 Email info hainke de Internet www hainke de 2 Electronic solenoid valve control V1 0 04 2022 Operation m...

Page 3: ...in the mounting enclosure 5 1 4 Notes on particular conditions for safe use in hazardous area Zone 22 5 2 Intended use 5 3 Technical data 6 4 Assembly and installation 7 4 1 Electrical connection 8 4...

Page 4: ...35 EU 2014 34 EU Applied standards EN 55014 1 2012 EN 60204 1 2012 EN 60079 0 2014 EN 60079 31 2014 The named standards and directives can be examined at HAINKE Filteranlagen GmbH 1 2 Marking electri...

Page 5: ...herwise the cover may not be opened while the installation is live Degree of protec tion IP54 must be maintained as a minimum 1 4 Notes on particular conditions for safe use in hazardous area Zone 22...

Page 6: ...e Colour RAL 7035 light grey Installation Wall mounted Degree of protection IP65 to EN 60529 Dimensions L W H 120 75 200 mm Weight 1 1 kg Cable entries 3 M16 Clamping areas of the cable entries M16 fo...

Page 7: ...losure The control in the mounting enclosure is suitable for mounting in the installation The operation is permitted for Hazardous area Zone 22 non conductive dust the potentially explosive medium doe...

Page 8: ...M 2 Connect the protective conductor to the grounding screw Solenoid valves 1 If 2 solenoid valves are connected connect both solenoid valves to terminals 1 and 2 and 3 and 4 respectively 2 If alterna...

Page 9: ...5 F E D C B A Datum Name Ma stab Blatt Elektronische Magnetventilsteuerung Typ FIW 202 E MASSPLAN 1 1 Masse ca A3 1 3 1 07 kg 120 200 89 188 3 x M 1 6 5 4 x 17 58 75 4 Assembly and installation Opera...

Page 10: ...ich gemacht werden Freigabedatum Freigegeben von Gepr ft von Gepr ft am Kundenfreigabe Freigabedatum FIW 1 2 3 4 PE L1 N x1 x2 PE x1 x2 PE FIW 1 2 3 4 PE L1 N x1 x2 PE FIW 1 2 3 4 PE L M x1 x2 PE FIW...

Page 11: ...to the connection plan 3 Check whether the correct microfuse is inserted 4 Apply the supply voltage according to the rating plate 5 Use the potentiometer to set the required pause and pulse time acco...

Page 12: ...Keeping the World Flowing for Future Generations...

Reviews: