Segmented mandrel T812.
Assembly
english
6.3.6 Assembly of the segmented mandrel [quick change-over
interface]
8.
x
Fig. 19
The assembly of the segmented mandrel from the quick
change machine adapter is described in the manual of
the machine adapter.
6.3.7 Checking and adjusting the face run and the concentricity
NOTE!
Material damage due to insufficient
face run and concentricity!
Due to insufficient face run and concentricity
work pieces can be damaged during processing.
After each mounting check, and if necessary re-
adjust, the face run and concentricity of the
clamping device.
Checking face run
Special tools required:
Dial indicator
Plastic tip hammer
Order H49 [0]7144. 907-333
39