11 Maintenance
11.1 Maintenance safety
WARNING
Serious injuries caused by parts being ejected
centrifugally after a loss of clamping power!
Maintain the maintenance and cleaning intervals
of the product at all times.
CAUTION
Health risks caused by incorrect handling of
cleaning agents!
Pay attention to hazard specifications and the
safety data sheet of the manufacturer.
INFORMATION
If necessary, use any forcing / extraction threads in
the components of the product, changing parts or
clamping elements.
11.2 Maintenance schedule
The following sections describe the maintenance work
needed to ensure optimum and fault-free operation.
If increased levels of wear are detected during regular
checks, shorten the maintenance intervals to reflect the ac-
tual rate at which signs of wear appear.
Contact the manufacturer for questions relating to mainte-
nance work and maintenance intervals [see »Contact« chap-
ter].
Interval
Maintenance work
daily
Visual inspection of wearing points, nicks and cracks [see the
»Visual inspection« chapter]
Visual inspection of the rubber on the CENTREX ring and on
the locating taper for wearing points, nicks and cracks [see
»Visual inspection« chapter]
Complete cleaning operation if heavily soiled [see the »Clean-
ing« chapter]
weekly or after 40 operating
hours
Remove the product [see the »Removal of the product« chap-
ter]
Remove, clean and reinstall the CENTREX ring [see the
»Cleaning« chapter]
every six months or after
1500 operating hours*
Clean the complete product [see the »Cleaning« chapter]
Lubricate the product [see the »Lubricating the product« chap-
ter]