![Hailo H-8 System Information Booklet Download Page 15](http://html1.mh-extra.com/html/hailo/h-8-system/h-8-system_information-booklet_3250475015.webp)
15
Cleaning:
• Remove soiling from the fall arrester using only
water and an acid-free detergent.
• The fall arrester should be allowed to dry natu-
rally. Drying underneath or against heat sources
is not permitted.
Storage:
• The SSL-8-R1 fall arrester must be stored in a
dry location to which the user has access.
Temperatures < -40 °C or > +50 °C or contact
with oils, acids or other corrosive liquids is not
permitted.
• The SSL-8-R1 fall arrester can be stored and
transported in the supplied packaging or a suit-
able container.
• DIN EN 353-1:2018-compliant fall arresters
must be inspected and documented for good
working order and functionality at least once a
year by trained/authorised personnel.
• The testing of all components, each individual
subsystem and system must be documented.
• In addition, regular checks must be made
depending on the respectively applicable
environmental conditions.
This can mean that the intervals between testing
are correspondingly shortened.
• The plant operator is responsible for ensuring
that testing and maintenance intervals are
observed.
Testing must adhere to the respective national
operating and testing regulations.
NOTE
Caution, damage!
Inexpert storage or transport may result in
damage to the SSL-8-R1 fall arrester and thus
to failure in the event of a fall.
8. Care instruction
9. Inspection instruction
WARNING
Risk of falling
Regular checks of the equipment are a
mandatory requirement.
The safety of the user is dependent on
the effectiveness and the durability of the
equipment.