Hailife FD-01B User Manual Download Page 14

11

 

 

 

Make sure your smart phone/tablet with: 
 Android 4.3 or above, CPU 1.4GHz or above, RAM 512MB or above, Bluetooth V4.0 or 
above ;      
 iPhone/iPad with iOS 8.0 or above,  CPU 1.0GHz or above, RAM 1GB or above, 
Bluetooth V4.0 or above. 

 

5.4. Switch on 

Press the Power Button on the front of device ( as showing in figure 1 ). The device will be 
ready for work when the power indicator is green. 

If the power indicator is red or not lighted, please check whether the connection of battery 
is reversed or the battery life is expiration, then adjust or change the battery. 

If the power indicator is still red or not lighted after adjust and change the battery, please 
contact us or your local distributor immediately. 

5.5. Open APP 

*Note: The feature is only available for the product with BLE feature support, If the 

product doesn’t support the feature, please skip to 

5.6.

 

Open APP “ Mywine ” in your smart phone or tablet. Choose one type of login : a) sign in 
with Email/Phone and password, or, b) Local mode. When you choose a), you need to 
register first. 

Then the Doppler will connect to the APP automatically after login the APP. 

 

1. Ensure the Bluetooth setting is “on” on your mobile phone. 

2. Ensure the distance between the device and your smart phone/tablet is less than 15 

meters. 

3. Only the user, who login with Email/Phone and password, can edit and share the 

recorded fetal heart beat curve to other people by public social media ( Facebook and 
twitter.  ) 

CAUTION

NOTE

Summary of Contents for FD-01B

Page 1: ...0...

Page 2: ...dong Province China Postcode 518100 Telephone Number 86 755 26928600 Fax 86 755 26928600 Terms Used in this Manual This guide is designed to give key concepts on safety precautions WARNING A WARNING a...

Page 3: ...5 4 3 ACCESSORIES 6 4 4 APP MYWINE 6 Section 5 Operation Instruction 7 5 1 OPEN THE PACKAGE AND CHECK 7 5 2 INSTALL REPLACING BATTERY 9 5 3 DOWNLOAD APP MYWINE AND INSTALL 10 5 4 SWITCH ON 11 5 5 OPEN...

Page 4: ...amination of these indices It is applicable for department of gynaecology and obstetrics and clinic daily In accordance with classification criteria in Annex IX on Medical Device Directive 93 42 EEC t...

Page 5: ...permitted leakage currents and dielectric strength of IEC EN 60601 1 1 WARNING and CAUTION messages must be observed To avoid the possibility of injury observe the following precautions during the op...

Page 6: ...e of flammable gases to avoid possible explosion or fire hazard 1 Keep the Doppler in a clean environment and avoid vibration during storage 2 Clean the surface of the device with non corrosive deterg...

Page 7: ...8 Manufacturer 9 Authorized Representative in the European Community 10 General symbol for recover recyclable 11 Refer to User Manual Background Blue Symbol White 12 Collect separately from other hous...

Page 8: ...4 2 Features Feature FD 01B FD 01 Bluetooth v4 0 Y N APP Y N Power indication Y Y Earphone Output Y Y Record fetal heart beat sound and curve Y N History data sharing Y N Battery low indication Y Y F...

Page 9: ...Y 4 Battery AA LR6 1 5V 2pcs Y Y 5 Ultrasound gel 1pcs Option Option Note Y means the accessory is included in the product N means the accessory is excluded in the product Note Ultrasound gel is an op...

Page 10: ...d this chapter and the chapter Safety Precautions before operation The Doppler can detect the fetal heart beats after 16 weeks gestation 5 1 Open the package and check Open the package check for any m...

Page 11: ...t installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installat...

Page 12: ...following the direction in figure 4 Then the battery cover is open Figure 4 Open battery cover Put the batteries into the device then put the battery cover back to device push it forward until it cli...

Page 13: ...sories in accordance with the directive 2002 96 EC WEEE Waste Electrical and Electronic Equipment If you have any queries please refer to the local authorities responsible for waste disposal 5 3 Downl...

Page 14: ...nd change the battery please contact us or your local distributor immediately 5 5 Open APP Note The feature is only available for the product with BLE feature support If the product doesn t support th...

Page 15: ...low to look for the point of fetal heart beat The best quality records will only be obtained if the probe is placed in the optimum position Figure 8 Optimum position for examing When the fetal heart b...

Page 16: ...the product doesn t have this feature please skip to 5 8 Click record button on APP Mywine while monitoring FHR the record button changes to APP begins recording the Fetus fetal heart sound and FHR c...

Page 17: ...in Quickening page Fetal movement will be statistic every 5 minutes multiple clicking the quickening button on main page and circle button in Quickening page within 5 minutes will be regarded as 1 ti...

Page 18: ...visible evidence of damage that may affect the operator s safety or the Doppler s capability before each use Pay special attention to the cracks on the device 6 2 Cleaning Please switch off the Doppl...

Page 19: ...nts or workmanship and the warranty claim is made within the warranty period Hailife will at its discretion repair or replace the defective part free of charge Hailife will not provide a substitute de...

Page 20: ...ns 8 1 Specifications ULTRASOUND Ultrasonic emitting frequency 2 5 MHz 10 Overall sensitivity at the distances 200mm from the face of the probe Doppler frequency 300 50Hz Targe velocity 10cm s 40cm s...

Page 21: ...700hPa 1060hPa 500hPa 1060hPa Section 9 Troubleshooting Phenomenon Cause Solution FD 01B FD 01 No sound Can be heard Mobile phone muted Bluetooth setting is off or No battery Unmute mobile phone Blue...

Page 22: ...uding domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes The Fetal Doppler is intended for use in th...

Page 23: ...tions Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordles...

Page 24: ...800 MHz 800 MHz to 2 5 GHz 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separatio...

Page 25: ...index value 0 01621 0 1380 0 2812 n a Index component value 0 0 0 1380 0 0 2812 0 Index label MI TIS TIB TIC At surface Below surface At surface Acoustic Parameters pr at zMI MPa 0 02564 P mW 0 12 62...

Page 26: ...23 pr at zPII MPa 0 02712 Operating control conditions Control Fixed Iob Isata 12 62 2 45 5 1510mW cm2...

Page 27: ...24...