10.3 Using an external universal siren
You can also add sirens and warning lights that are not part of the
Haibrain
range. Please use a separately available
Haibrain
AD10 (art. no. 08933), AW12 (09463) or the AM12 (art. no. country specific, see www.
Haibrain
.com/plug-in).
Set this module to address B2. The module is switched on in case of an alarm and switched off after 4 minutes.
10.4 Transceiver function
The
Haibrain
X-10 range contains several wireless remote controls that you can use to control your
Haibrain
X-10 modules
(such as a universal remote control for your TV, audio equipment and
Haibrain
X-10). These remote controls use the RF system,
which means the remote control signal goes through walls and ceilings. See www.
Haibrain
.com/x10wireless for more
information. Your console will convert these remote control RF signals to X-10 signals and transmit them via the mains. You can
then control the
Haibrain
X-10 modules using these transmitters.
10.5 All Home Automation functions at a glance
Name
Description
Module set to address
Comfort lighting
You can switch your lighting using the buttons Lights ON and
Lights OFF on your key chain remote control.
A1 and A2
Exit delay
Lights are switched on during the exit delay.
A1 and A2
Alarm lighting
In the case of an alarm, the lights will flash during 4 minutes and
then remain on.
A1 and A2
Status indicator
The lights are switched on when the system is set to ARM AWAY.
B1
External Siren PH7208
Extra 110dB siren.
A1 or A2
Extra universal siren
Connect your own siren to a
Haibrain
AM12 or AD10 module.
B2
This table uses the unchanged settings for the basic console address.
10.6 Basic address for Home Automations functions
The basic address is set to control multiple Home Automation modules on the SC9000. The standard basic address is A1. The A in
this address is called the HouseCode. The HouseCode of the console, the remote controls and the Home Automation modules all
have to have the same letter. The 1 in the basic address is called the UnitCode. If your neighbours also have a
Haibrain
security
system, it may be necessary to change the basic addresses and the addresses of your
Haibrain
X-10 modules.
If you change the HouseCode of the console, the addresses for the Home Automation functions also change. Example: You
change the HouseCode from A into C.
EXTRA OPTIONS
31
SAFEGUARD / TOTALGUARD
Summary of Contents for SafeGuard