7
Note: When you run the unit and manually fill it, check the water level
frequently so it does not run dry. Operating the pump without water will
damage it or reduce its service life. This is not covered by the warranty.
The cooling effect also stops if the pads are dry.
COOLING PAD ASSEMBLY
Unit placement and other considerations
The unit(s) should be placed at one end of the building and an appropriate
exhaust fan should be at the opposite end to pull the cool air from the unit
and discharge the warm air out of the building.
Try to get all the air flowing in the same direction. Do not direct other fans
against the unit. It will counter the airflow and reduce the cooling effect.
Obstructing the airflow from the unit severely reduces the cooling effect.
Avoid using ceiling fans as they disrupt the airflow from the unit.
Use as many exhaust fans as possible to create a natural draft through the
building. This will enhance the performance.
UNPACKING AND INITIAL SETUP
The Evaporative Cooler is shipped upright. The unit is fully assembled and
ready for service except for thoroughly cleaning manufacturing dust from
the cooling pads before running it for the first time.
CAUTION: Be careful when you move the unit. Avoid jarring or
dropping the unit to prevent damage to the bottom.