Haier YR-E06 Operation Manual Download Page 5

Just press TIMER button several times until TIMER mode disappears.

OFF

ON

OFF

ON

OFF

Used to select Auxiliary electric heater.

2

RESET

LOCK

SLEEP

FAN

TEMP

ON

OFF

SWING

MODE

CLOCK

CODE

LIGHT

Battery loading
Batteries are fitted as follows:

Loading the battery

Ensure that batteries are correctly placed in the compartment
as required for positive and negative terminals.

Replacing the battery compartment lid

The battery compartment lid is reinstalled in the reverse
sequence.

Display review

Press the button to see if batteries are properly fitted. If no
display appears, refit the batteries.

Remove the battery compartment lid
Slightly press and disengage the battery compartment lid marked
with 

"  " 

 and then hold the remote controller by the upper

section and then remove the battery compartment lid by pressing
in the direction of the arrow as shown in the figure above.

Note:
It is recommended that the batteries be removed from the
compartment if the remote controller is not used for an extended
period.
The remote controller is programmed for automatic test of
operation mode after the batteries are replaced. When the test
is conducted, all icons will appear on the screen and then
disappear if the batteries are properly fitted.

When the display become weak, this display no power
in the battery, please change the battery.

Caution:
If the remote controller does not operate as designed after
fitting new batteries of the same
type, press the Reset button (marked   ) with a pointed article.

+         -

-          +

RESET

LOCK

SLEEP

MODE

CLOCK

CODE

LIGHT

A
U
T
O

A
U
T
O

7

blank

ON

Operation mode will be displayed on LCD.
Power indicator lights up.

Every time the button is pressed, display changes as
follows:

Select        .

(3)Time setting for TIMER ON

Press TIME button.

(5)Time setting for TIMER OFF

To cancel TIMER mode

Every time the button is pressed, time increases 10min.
If button is kept depressed, time will change quickly.
Every time the button is pressed, time decreases 10min.
If button is kept depressed, time will change quickly.
Time will be shown on LCD.
It can be adjusted within 24hours.

AM refers to morning and PM to afternoon.

Time displayed: Unit starts  at Xhour X min.

After time setting, press TIMER button to
confirm."ON" stops blinking, While "OFF"
starts blinking.

(4) Time confirming for TIMER

Follow the same procedures in "Time setting
for TIMER ON".

(6)Time confirming for TIMER OFF

After time setting, press SET button to confirm
"OFF" stops flashing.

Time displayed: Unit stops at X hour X min.

According to the Time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or Stop-Start

can be achieved.

(1)After unit start, select your desired operation mode

(2) Press TIMER button to change TIMER mode

ON
OFF

Operation

The function of code A:TIMER ON/OFF

FRESH

HIGH/SO

TIMER

SET

FILTER

A

HEALTH

1

HEAT

*

MODE

FAN

HEALTH

TEMP

CLOCK

SET

TIMER

SLEEP

RESET

FILTER RESET

ON/OFF

PM

AM

1

SET

SWING

HEAT

6

3

2

4

5

4

Parts and Functions

When operating the remote controller in an area where
electronically controlled lights are installed or wireless handsets
are used, please move closer to the indoor unit as the function
of the remote controller might be affected by signals emitted by
the above mentioned equipments.

Battery loading

Confirmation indicator

If no indication is displayed after press ON/OFF button,
reload the batteries.

Remote Controller Operation

When in use, direct signal transmission head to
the receiver placed on the indoor unit

The distance between the  remote controller and the receiver
should be max 7m and there should be no obstacle between them.
Do not throw the remote controller; prevent it from being damaged.

Clock Set

When unit is started for the first time and after replacing batteries in remote controller, clock should
be adjusted as follows:

1.Press CLOCK button, clock indication of " AM " or " PM " flashes.
2.Press      or      to set correct time. Each press will increase or decrease 1 min. If the button is kept
pressed, time will increase or decrease quickly.
3.After time setting is confirmed, press "SET" : AM or PM stop flashing, while clock starts working.
Note:AM means morning and PM means afternoon.

FRESH

HIGH/SO

TIMER

SET

FILTER

HEALTH

HEAT

16.FRESH Button

Used to set fresh mode, the unit will draw in fresh air.

Displays when healthy run function is set.

22.TEMPERATURE Display

34.LOCK State Display

33.BATTERY Energy Display
Notify the user when it is time to change the batteries.

24.HIGN/SO Run Display

26.SIGNAL SENDING Display

28.Fresh Display
29.Auxiliary ELECTRICAL HEATING Display
30.HEALTH Display

32.SLEEP State Display(

 

In function of code A)

31.Operation MODE Display

35.FAN SPEED Display

23.AUTO SWING Display

20.TIMER Display
21.FILTER Display

36.TIMER ON Display

17.SLEEP Button(In function of code A)

(The clock must be corrected before setting sleep function)

Used to set sleep mode.
18.FAN Button
Used to select fan speed:LOW,MID,HIGH,AUTO.
19.TIMER OFF Display

When the filter need be cleaned, the sign will
appear automatically.

25.Code A display

27.Code B display

The function of code A

The function of code B

LOW

MID

HIGH

AUTO

LOW

MID

HIGH

AUTO

37.HEAT Button

1

4

5

6

3

2

3

Summary of Contents for YR-E06

Page 1: ...rmed Hint 1 Power supply switch and signal wire should be prepaired by the user 2 Don t touch PCB with hand Be careful not to hold down the wiring 1 Remove upper cover of wire controller Remove upper part of wire controller by press Lower cover of wire controller Upper cover of wire controller 2 Install the wired remote controller Please drill two holes on the wall according to the back cover scre...

Page 2: ...l window of the remote control receiver 2 Series remote controller units please press the botton CODE to choose the program of code B 3 Series remote control units have not power failure compensation fig 2 FRESH HIGH SO TIMER SET FILTER B A M D HEALTH FRESH HIGH SO TIMER SET FILTER B A M D HEALTH Parts and Functions HEAT HEAT HEAT HEAT SET ROOM MODE FAN TEMP CLOCK SET TIMER SLEEP RESET FILTER RESE...

Page 3: ... the Switch On Off button after the power comes again If the controller no sleep key use the swing key instead the sleeping on setting the auto restart function After the Auto restart is set if power failure suddenly occurs while the air conditioner is working it will resume the previous working state when the power is supplied again Used to adjust the time of timer and clock When the wire control...

Page 4: ... TIMER SET FILTER B A M D HEALTH RESET LOCK SLEEP FAN TEMP ON OFF SWING MODE CLOCK CODE LIGHT OFF A U T O 25 26 21 23 17 15 18 19 22 24 27 20 14 16 36 1 2 3 4 6 7 9 10 5 8 34 33 28 32 31 30 35 29 The function of code A Used to select TIMER mode TIMER ON TIMER OFF The function of code B 8 5 2 16 28 30 33 29 14 11 17 21 24 HEAT 13 37 12 11 HEAT COOL DRY 8 At night before going to bed you can press d...

Page 5: ...it stops at X hour X min According to the Time setting sequence of TIMER ON or TIMER OFF either Start Stop or Stop Start can be achieved 1 After unit start select your desired operation mode 2 Press TIMER button to change TIMER mode ON OFF Operation The function of code A TIMER ON OFF FRESH HIGH SO TIMER SET FILTER A HEALTH 1 HEAT MODE FAN HEALTH TEMP CLOCK SET TIMER SLEEP RESET FILTER RESET ON OF...

Page 6: ...H SO TIMER SET FILTER A HEALTH 1 5 4 Operation The function of code B AUTO COOL DRY FAN HEAT The function of code A COOL DRY HEAT LOW MID HIGH AUTO The function of code A The function of code B LOW MID HIGH AUTO FILTERRESET HEAT HEAT 6 Hints Set Clock correctly before starting Timer operation You can let unit start or stop automatically at following time Before you wake up in the morning or get ba...

Reviews: