49- 5000430 Rev. 4
5
E
N
G
L
IS
H
CONTROLS
Controls
NOTE:
When the bucket is full or removed, the controls cannot be set.
1. Power Pad
Press t o t urn t he dehumidifier on and off.
NOTE:
Turning off t he power by pressing t he Power but t on does
NOT disconnect t he appliance from power supply.
Cont rols t he fan speed.
Press to select either High, Medium, Low, or Smart Dry fan speed.
Set t he fan cont rol t o High for maximum moist ure removal. When
t he humidit y has been reduced and quiet operat ion is preferred,
set t he fan cont rol t o Medium or Low.
Smart Dry compares t he set humidit y level wit h t he act ual
humidit y and adjust s t he fan speed aut omat ically.
3. Display
Shows t he set % humidit y level while set t ing, t hen shows t he
act ual (+/ – 5% accuracy) room % humidit y level.
Ýëèëøðìçì÷üïèùèïæäñåèöè÷úì÷ëìñäõäñêèòé#%]ÛѤÛèïä÷ìùè
Ñøðìçì÷ü¥÷ò( ]ÛѤÛèïä÷ìùèÑøðìçì÷ü¥ìñ%]ìñæõèðèñ÷öòõ
in Nonst op mode for cont inuous operat ion. To set t he unit for
cont inuous operat ion, press t he pad unt il t he “Nonst op”
indicat or light is illuminat ed.
NOTE:
If Nonst op is select ed, t he dehumidifier will operat e
cont inuously at it s maximum dehumidificat ion set t ings if
at t ached t o a hose t o drain or unt il t he bucket is full.
For drier air, press the pad and set to a lower percent value (%).
For damper air, press the pad and set to a higher percent value (%).
When you first use t he dehumidifier, set t he humidit y cont rol
t o 45% or 50%. Allow at least 24 hours for t he dehumidifier
t o achieve t he humidit y level. If you st ill have damper air t han
desired, set t he humidit y level t o a lower set t ing or select
Nonst op for maximum dehumidificat ion.
5. Filter Timer
After 250 hours of operation, the Clean the Filter indicator light will
glow to remind you to clean the filter. Remove the filter and clean it.
Press and hold
Filter
but t on for 3 seconds t o reset t he filt er
reminder. See t he Care and Cleaning sect ion.
6. Delay Off
While t he dehumidifier is operat ing press t he
Delay
but t on.
Press t he / but t ons t o select t he number of hours you want
t he dehumidifier t o cont inue t o operat e before t urning Off.
NOTE:
Aft er displaying t he t ime, t he Display will revert t o
showing t he current humidit y aft er 5 seconds have passed.
Pressing t he
Delay
but t on will display t he number of hours left on
t he delay.
Delay On
While t he dehumidifier is off press t he
Delay
but t on.
Press t he / but t ons t o select t he number of hours you
want t he dehumidifier t o remain off before t urning On.
NOTE:
The display will show t he number of hours left unt il t he
dehumidifier t urns on.
To cancel the Delay:
Press t he
Dela
y but t on once, t he hours remaining on t he Delay
will appear on t he display. Press t he
Delay
but t on again and t he
Delay will be cancelled.
7. Empty Indicator
The “Empt y” indicat or will blink when t he bucket is ready t o be
empt ied, or when t he bucket is removed and/ or not replaced in
t he proper posit ion.
Appearance may vary by model.
Other Features
Alarm
If t he bucket is full or missing, an alarm will sound for about 10 seconds t o
remind you t o empt y and replace t he bucket .
Auto Shut Off
The Wat er Level Cont rol Swit ch shut s off t he dehumidifier when t he bucket
is full, or when t he bucket is removed and/ or not replaced in t he proper
posit ion.
NOTE:
The fan and compressor will st op running as soon as t he bucket is
removed. The alarm will sound if t he bucket is not replaced in t he proper
posit ion aft er 3 minut es.
Auto Defrost
When frost builds up on t he evaporat or coils, t he compressor will cycle off
and t he fan will cont inue t o run unt il t he frost disappears.
Power Outage
In t he case of a power out age or int errupt ion, t he unit will aut omat ically
rest art , in t he set t ings last used, aft er t he power is rest ored.