background image

Assembly Instruction

Notice: The solar water heater shall be installed by professional.

Exterior and installation dimension:

4

Models

Exterior dimension(mm) Installation  dimension(mm)

1. Please install the solar water heater in the area that avoid the thunder.

2. Solar water heater angle range: east to south for 10

, west to south for 15

.

3. There shouldn't be any hindrance in front of the heater ,or the distance should over 

    L,  L=H/tg(66.5

a

)

H:height of the hindrance;

a

: latitude of the area

Remarks:

The permitted error limit of above  parameters is 

 10%.

The location

:

A

D

QBJ1-130A58E

QBJ1-150A58E

QBJ1-175A58E

QBJ1-200A58E

B

H

QBJ1-230A58E

QBJ1-270A58E

Summary of Contents for QBJ1-130A58E

Page 1: ...Instruction for use QBJ1 130A58E QBJ1 150A58E QBJ1 175A58E QBJ1 200A58E QBJ1 230A58E QBJ1 270A58E Please read this manual before usage Retain it for future reference Solar Water Heater ...

Page 2: ......

Page 3: ...location Exterior and installation dimension Tank assembly Frame assembly Frame fastness Glass tube assembly Extraventricular plumbing instructions Indoor plumbing instructions Installation notice Using Instruction The operation method Troubles treatment 3 Pipelines thermal insulation notice 9 The product with controller installation and using notice 9 Packing list ...

Page 4: ...ll glass evacuated tubular collector 45 Remarks 1 The warp of a parameters is 3 the warp of usable water parameters is 5 The permitted error limit of other parameters is 10 perture area QBJ1 130A58E QBJ1 150A58E QBJ1 175A58E QBJ1 200A58E 14 16 19 22 2 1 79m 2 2 07m 2 2 48m 2 2 90m 130L 150L 175L 200L Electric auxiliary heating Rated power 1500W Water level sensor Using the water level sensor with ...

Page 5: ...the water couldn t be supplied normally due to the low fall 7 Do not supply cold water more than once in a low solar irradiance day 8 The energy is from solar in the days that lack of solar such as rainy or snowy day the temperature of the water may can t reach your demand 9 Make sure the evacuated tubes clean hose off the dust and dirt on the tubes and the reflector before the winter comes 10 The...

Page 6: ...duction 1 Please check out the packing list 2 If you fix electric auxiliary heating and controller please select Haier equipped products 3 To avoid the scald please mix the hot and the cold water before use it 4 In order to protect the tank please don t refit or wall up the air supply pipe and the overflow pipe ...

Page 7: ... in the area that avoid the thunder 2 Solar water heater angle range east to south for 10 west to south for 15 3 There shouldn t be any hindrance in front of the heater or the distance should over L L H tg 66 5 a H height of the hindrance a latitude of the area Remarks The permitted error limit of above parameters is 10 The location A D QBJ1 130A58E QBJ1 150A58E QBJ1 175A58E QBJ1 200A58E B H QBJ1 ...

Page 8: ...bracket Frame assembly Please consult the accessional paper for figure of the frame and packing list in the packing of frame Frame fastness 1 Peg the feet of the heater into the earth with prepared iron or into the concrete brick with intumescent bolt 2 Adjust the height of the frame with the water proof cushion to keep the tank aclinic and each foot balanceable Notice 1 Make sure that the feet ar...

Page 9: ...sert tube into base support C 5 Slide the tube down 1 cm Slide black rubber seal up the tubes until it sits flush with tank D 6 Insert one tube on either end of the tank to achieve alignment of unit Notice 1 Make sure the silicon seal ring are clean and well positioned 2 Place the rounded side of rubber seal downwards on open end of tube Slide it down 10 cm Wet open end of tube to make it easier t...

Page 10: ...m Air supply hole 1 2 forbidden to stem QBJ1 130A58E QBJ1 150A58E QBJ1 175A58E QBJ1 200A58E A b a Remarks The permitted error limit of above parameters is 10 Electric heating flange a b Sensor hole 3 4 Sensor Electric heating pipe Connect racing belt the line of t Water level sensor Electric heating Pre burrided cord slot Solar water heater Hot water Tap water Controller QBJ1 230A58E QBJ1 270A58E ...

Page 11: ...e and the cloaca should less than 15cm Don t placed the pipe optionally so can avoid the water spatter 4 Don t install the valve in the pipeline to insure that the signal which shows the water is overflow will be worked normally 5 To avoid the water in the tank flow inverted an unilateralism valve should be installed at the joint of the water pipe and the tap water 6 The installation project shoul...

Page 12: ...controller please select Haier products otherwise our company won t be responsible for personal injure and damage of water heater 2 Haier has the controller used in domestic water heater which has cord and plug and they are connected well Please select the electrical outlet of good quality its rated current is not less than 16 A and must ground reliably 3 The cord of controller mustn t be layed in...

Page 13: ...anger it must be replaced by factory or maintenance department or professional staff 9 Other requirements refer to controller introduction The operation method 1 K1 valve is open before using water K2 K3 valves are closed 2 The controller is set in the status of automatical water supply the electromagnetic valve won t close until arriving at the set water level and water supply is over 3 Open K2 w...

Page 14: ...nt of it Treatment Supply water according to the manual Maintain the pipeline or clean the connection Replacing the tubes Waiting for the supplying again Maintain the pipeline and the connection Screw down the valve or replacing it Change the location or move the hindranc Using Instruction 11 The controller can t reach the programmed level or there is no water Too much ash on the tube Tidy the tub...

Page 15: ......

Page 16: ...Rev 01 Specific Number 0040500680F Made in China ...

Page 17: ...HR QBJ1 KSD Instruction for use Solar water heater controller Please read this manual before usage Retain it for future reference ...

Page 18: ...Product Instruction Main technical specification Main function Switch on off the controller and parameters setting Main function operation Error display and handling Electric water heater water temperature and level sensor installation Indoor pipe and electromagnetic valve installation notice Installation notice Controller installation Wiring 11 13 Packing list ...

Page 19: ...ure and water level sensor electromagnetic valve electric heater cable etc Working principle Water level and temperature sensor detects real time water level and temperature signals these signals being amplified and A D converted are transmitted into the CPU the CPU displays the relevant data and user s setting information with the measured data and judging CPU issues kinds of controlling instruct...

Page 20: ...essure 0 02MPa 0 8MPa 11 Exterior dimensions 182mm 130mm 48mm 12 Allowable environment humidity 90 RH 13 Waterproof grade IPX4 Function Instruction 2 Control panel Function Instruction A B C D E F B Time activated A Anti freezing adjusting C Manual heating D Manual water supply E Set F Power 1 Anti freeze sign the sign shows that self limiting electricity heating belt is working flicker shows it i...

Page 21: ...ll activate automatically electric heating will be shut down automatically when the water temperature reaches the pre set temperature 6 Automatic water supply when controller shows no water for 15 minutes the system will open electromagnetic valve to supply water automatically 7 System resume when blackout the battery built in the controller will backup the pre set information when electrified aga...

Page 22: ...ke the electric heating will not activate to protect the electric heater from damage At this time water supply will automatically activate to supply water until the water reaches the second level then electric heater will be activated automatically 11 Vacuum tube anti bombing when water temperature is higher than 90 and there is no water in tank water supply can t be activated 12 Safety protection...

Page 23: ...y is being adjusted turns bright and hour or minute are flickering it means electric heating time is being adjusted 5 When the system is in set mode setting parameters are flickering except the function which is being set there is no effect on the other functions For example the water supply time can be adjusted while heating Using Instruction and exit from the set mode Continue to press key to en...

Page 24: ... is lower than the set value water supply will be activated automatically and stop until reaching the pre set water level 2 When displaying press key the display goes out time water supply is cancelled In this state press key until displays it will be activated 3 In the process of water supply sign displays 4 When the water reached the pre set water level water supply will stop automatically in 10...

Page 25: ...tional function 1 Function choice A Cut off electric power pick the switch of back cap wiring onto antifreeze side B Switch on machine sustainablly press key enter the mode of anti freeze pump choice press key until antifreeze sign flickers it means electricity heating belt has been chosen Read more operation details in the section of Parameters setting 2 Press key the sign displays it shows pipel...

Page 26: ... display on the water temperature area 2 The simple analysis and processing of fault shows as follows Cause of malfunction Malfunction handling 1 Connected to power without pressing key 2 The fuse breaks 3 No power 1 Press the key to start up 2 Replace fuse 3 Check whether the plug is firmly plugged in No display Phenomenon and codes of malfunction DisplayE5 Current creepage DisplayE1 Temperature ...

Page 27: ...it wiring are connected directly Water level display doesn t accord with the actual value 1 The surface of sensor is dirty 2 The sensor disabled 1 Unload the sensor and clean then install it back 2 Replace the sensor Water can t be supplied 1 The local hydraulic pressure is low 2 The electromagnetic valve filter is blocked up 3 The electromagnetic valve disabled 1 Install pump 2 Clean the electrom...

Page 28: ...led to behind the water temperature and level sensor their color are red blue green yellow remove the white jacket of the sensor s signal wire and the wire led to indoor cut the jacket and wire to make them regular Fill two signal wires with same color in the terminal s hole and press tight with pincers B Use waterproof and insulated tape to seal the connection firmly Installation Instruction Term...

Page 29: ... direction of the arrow labeled on the electromagnetic valve is the direction of inlet wrong connection is not allowed 4 The electromagnetic valve should be installed horizontally the junction box is upward The filter in the electromagnetic valve s inlet can clear the impurities in pipe 5 Prohibit using tools such as wrenches to operate in the coil and plastic parts both pipe ends of electromagnet...

Page 30: ...onnected to antifreeze B Pressure 1 2 Water level 5 6 E separately connects blue and red wires 3 4 Temperature separately connects yellow and green wires lectromagnetic valve electromagnetic valve arbitrarily the sensor has four wires blue one and red one are water level wires they are joined to the two terminal of water level the green one and yellow one are water temperature wires they are joine...

Page 31: ...lip Plastic expander tube Self tapping screw Self tapping screw Self tapping screw Self tapping screw Size specification HR QBJ1 KSD 6 ST 4 25 cross slot and round head ST2 9 6 5 cross slot and round head ST2 9 9 5 cross slot and flat head ST2 9 9 5 cross slot and round head Quantity Packing list ...

Page 32: ...Rev 01 Specific Number 0040500680G ...

Reviews: