Drawing for the installation of indoor and outdoor units

Necessary Tools for Installation

ƽ

Torque wrench

ƽ

(17mm,22mm,26mm)

Nipper

ƽ

Reamer

ƽ

Hacksaw

ƽ

Pipe cutter

ƽ

Gas leakage detector or

ƽ

soap-and-water solution

Hole core drill

ƽ

Flaring tool

ƽ

Spanner(17,19 and 26mm)

ƽ

Knife

ƽ

Measuring tape

ƽ

ƽ

Selection of Installation Place

Power Source

Preparation

The above picture is for reference only. Your product may look different.

Read this manual before installation
Explain the operation of the unit to the user according to this manual

NO.0010538926

Installation Manual of Room Air Conditioner

F

A

C

E

D

Optional parts for piping

Non-adhesive tape

Adhesive tape

Saddle (L.S) with screws

Connecting electric cable

for indoor and outdoor

Drain hose

Insulating material

Piping hole cover

Floor fixing dimensions of the outdoor unit 

Fixing of outdoor unit

Fix the unit to concrete or block

ƽ

with bolts

(10mm) securely.

When fitting the unit to wall

ƽ

surface, roof or

rooftop, fix the unit securely in consideration

of earthquake and strong wind.

If vibration may affect the

ƽ

house, fix the unit

by attaching a vibration-proof mat.

The marks from

to

in the figure are the

name of the parts.
The distance between
the indoor unit and the
floor should be more
than 2m or 6 feet.

The models adopt HFC free refrigerant R410A

more than
10cm

more than 5cm

more than 10cm

more than 10cm

more than15cm

more than 60cm

A

G

ƽ

ƽ

A

F

C

E

D

G

B

Arrangement of piping
directions

Rear left

Left

Rear
right

Right

Below

G

Attention must be paid to

the pitch of drain hose

X

Y

X

Z

Dimensions(mm/inches)

Model

x

y

z

140

500

256

140

500

256

583

319.5

113.5

633

340

HSU09VHG(DB)-W 

HSU12VHG(DB)-W

HSU18VHG(DB)-W

HSU24VHG(DB)-W

Hammer

ƽ
ƽ

ƽ

ƽ

Place where the distance of more than lm from televisions, radios, wireless apparatuses
and fluorescent lamps 3 feet or approximately.

ƽ

In the case of fixing the remote controller on a wall, place where the indoor unit can
receive signals when the fluorescent

ƽ

lamps in the room are in use.

ƽ

ƽ

ƽ

A distance marked

ƽ

Q

is available as illustrated in the below figure.

Indoor Unit - Select a location that is

Outdoor Unit - Select a location that is

Robust not causing vibration, where the unit can be supported s ufficiently.

Not affected by heat or steam generated in the vicinity, and where the inlet and outlet of  
the unit are not disturbed.
Possible to drain easily, and where piping can be connected with the outdoor unit.

Where conditioned air can be spread in a room evenly.

Less affected by rain or direct sunlight and is sufficiently ventilated.
Strong enough to bear the unit, where vibration and noise are not increased.

Not causing a nuisance to neighbors due to discharged air or noise. 

 (Unit:mm / inch)

(5 1/2)

(5 1/2)

(4 1/2)

(4 1/2)

113.5

(19 2/3)

(19 2/3)

(23)

(24 7/8)

(10 1/16)

(10 1/16)

(12 5/8)

(13 1/2)

(1 15/16 inches)

(3 15/16
 inches)

(3 15/16 inches)

(3 15/16 inches)

more than 10cm

(3 15/16 inches)

(5 7/8 inches)

(23 5/8 inches)

All wiring to the unit must be in accordance with the National Electric code 

and local ordinances.

Summary of Contents for Novel HSU12VHG-W

Page 1: ...A G ƽ ƽ A F C E D G B Arrangement of piping directions Rear left Left Rear right Right Below G Attention must be paid to the pitch of drain hose X Y X Z Dimensions mm inches Model x y z 140 500 256 140 500 256 583 319 5 113 5 633 340 HSU09VHG DB W HSU12VHG DB W HSU18VHG DB W HSU24VHG DB W Hammer ƽ ƽ ƽ ƽ Place where the distance of more than lm from televisions radios wireless apparatuses and fluore...

Page 2: ...n materials 1 Insert the drain hose into the carity of heat insulation materials of indoor unit 2 Insert the indoor outdoor electric cable from backside of indoor unit and pull it out on the front side then connect them 3 Coat the flaring seal face with refrigerant oil and connect pipes Cover the tubing connection with insulation materials closely and with adhesive tape Fixing the indoor unit body ...

Page 3: ...ndoor unit Indoor unit C 3 N 1 L 2 C 3 N 1 L 2 Outdoor unit Indoor unit Outdoor unit 1 2 N 2 3 C L 1 Max Elevation Amax 32ft 10m 09k 12k 50ft 15m 18k 24k In case the elevation A is more than 15ft 5m oil trap shoud be installed every 5 7m Max Length Bmax 50ft 15m 09k 12k 80ft 25m 18k 24k HSU09VHG DB W HSU12VHG DB W HSU18VHG DB W HSU24VHG DB W ƽ ƽ ƽ Insert the cord from the back side of the unit the...

Page 4: ...for Installation and Test Run Ƶ Ƶ 1 1 2 kg R410A 2 kg 2 1 B C D F E kg A This product contains fluorinated greenhouse gases covered by the Kyoto Protocol Do not vent into the atmosphere Refrigerant type R410A GWP value 1975 GWP global warming potential Please fill in with indelible ink 1 the factory refrigerant charge of the product 2 the additional refrigerant amount charged in the field and 1 2 ...

Page 5: ...remotos o viento fuerte Si la vibración afectase a la casa fije la unidad instalando una alfombra de absorción de vibraciones Recuerde que la ilustración anterior podría no reflejar fielmente el producto adquirido y debe utilizarse únicamente como referencia Lea este manual antes de la instalación Explique el uso del aparato al usuario siguiendo las instrucciones de este manual 5 X Y X Z Dimensiones ...

Page 6: ...frigerante y conecte los tubos Cubra la conexión con material aislante de calor y asegúrese de fijarla con cinta adhesiva Los cables eléctricos de interior exterior deben conectarse a la entubación del refrigerante utilizando cinta protectora Entubación en otra dirección Corte con una cuchilla la cubierta de entubación de acuerdo con la dirección de entubación y doble los tubos de acuerdo con la po...

Page 7: ...ado El tipo de cable de conexión es H05RN F o H07RN F 2 Si el fusible de la placa PC está roto cámbielo por otro de tipo T 3 15A 250VAC Interior T 25A 250VAC Exterior 3 El método de cableado debe satisfacer los requisitos de las normas locales de cableado 4 Después de la instalación el enchufe de alimentación debe encontrarse ubicado en un lugar fácilmente accesible 5 Debe instalarse un interrupto...

Page 8: ...ca de la conexión de carga del producto por ejemplo sobre la parte interna de la cubierta de la válvula de retención A Contiene gases fluorados de efecto invernadero regulados por el Protocolo de Kioto B Carga de refrigerante que contiene el producto de fábrica consulte la placa de características de la unidad C Cantidad de refrigerante adicional cargada durante la instalación D Carga total de refr...

Page 9: ...te des séismes et vents forts Si des vibrations risquent d affecter la maison fixez l unité avec un tapis anti vibration L illustration ci dessus est indiquée à titre de référence uniquement vous devez tenir compte des particularités du modèle acheté Lisez ce manuel avant de procéder à l installation Communiquez à l utilisateur suffisamment d informations sur l exploitation de l unité selon ce manue...

Page 10: ...mique et fixez avec du ruban adhésif Le câble des unités intérieures extérieures et le tuyau de vidange doivent être fixés au tuyau de réfrigérant avec un ruban protecteur Tuyauterie dans une autre direction A l aide d une pince découpez le couvercle pour la tuyauterie en fonction de la direction de la tuyauterie et cintrez ensuite le tuyau selon la position du trou dans le mur Lors du cintrage pren...

Page 11: ...2 Si le fusible de la carte PC a fondu changez le avec le type T 3 15A 250VAC unité intérieure T 25A 250VAC unité extérieure 3 La méthode de câblage doit être conforme aux normes locales de câblage 4 Après installation la prise de courant doit être d accès facile 5 Un disjoncteur doit être incorporé au câblage fixe Le disjoncteur doit être omnipo laire et la distance entre ses deux contacts ne doit...

Page 12: ...eignée doit être collée à proximité du port de chargement de l appareil par ex sur l intérieur du couvercle de valeur d arrêt A Contient des gaz à effet de serre fluorés couverts par le protocole de Kyoto B Charge de réfrigérant standard de l unité voir sur la plaque signalétique de l unité C Quantité supplémentaire de réfrigérant chargée sur place D Charge totale de réfrigérant E Unité extérieure ...

Reviews: