background image

Maintenance

Setting of proper room
temperature

Close doors and windows
during operation

If the unit is not to be used
for a long time, turn off the
power supply main switch.

Use the timer effectively

Use the louvers effectively

Do not block the air inlet
or outlet

Proper

temperature

During cooling operation

prevent the penetration 
  of direct sunlight with

curtain or blind

OFF

Remote Controller

Indoor Body

1.Open the lnlet Grille

2.Detach the standard air filter

3.Attach Air Purifying Filter

4.Attach the standard air filter

(Necessary installation)

5.Close the Inlet Grille

Close the Grille surely

Slide the knob slightly upward to 
release the filter, then withdraw it.

Put air purifying filter appliances into the

right and left filter frames.

NOTE:

The photocatalyst air purifying filter will be solarized in fixed

time. In normal family, it will be solarized every 6 months.

Prop up the inlet grille by using a

 small device named grille-support 

ATTENTION:

Please keep the bacteria-killing medium air purifying filter in

avoid long time directly sunshine

when you stop using it,or its ability of sterilization will be

reduced.

The bacteria-killing medium air purifying filter will be used 
for a long time,no need for replacement. But in the period 
of using them ,you should remove the dust frequently by 

which located in the right side of

 the indoor unit. 

using vacuum cleaner or flaping them lightly,otherwise ,

its performance will be affected. 

the cool and dry conditions

For Smart Use of The Air Conditioner

Replacement of Air Purifying Filter

The white side of the photocatalyst air purifying filter 
face outside,and the black side face the unit The green 
side of the bacteria-killing medium air purifying filter face 
outside,and the white side face the unit.

Do not usewater,wipe the controller
with a dry cloth.Do not use glass
cleaner or chemical cloth.

wipe the air conditioner by using a 
soft and dry cloth.For serious stains,
use a neutral detergent diluted with
water.Wring the water out of the 
cloth before wiping,then wipe off the 
detergent completely.

Air Filter cleaning

Open the inlet grille by pulling it upward.

Remove the filter.

Clean the filter.

Attach the filter.

Close the inlet grille.

Push up the filter's center tab slightly until it is 

from the stopper, and remove the filter downward.

Use a vacuum cleaner to remove dust, or  wash the filter with
water.After washing, dry the filter completely in the shade.

Attach the filter correctly so that the "FRONT" indication

facing to the front.Make sure that the filter is 

fixed behind the stopper.If the right

attached correctly, that 

Do not use the following for cleaning

Gasoline,benzine, thinner or cleanser

ay damage the coating of the unit.

Hot water over 40

O

C(104

O

F) may

discoloring or deformation.

Once every
two weeks

m

cause

released

 is

completely

and left filters are not

may cause defects.

Detach old Air Purifying Filter

8

Summary of Contents for Nederlands

Page 1: ...e reference This appliance is filled with R32 SPLIT TYPE ROOM AIR CONDITION OPERATION MANUAL 0010595836 ER AS09FBAHRA AS12FBAHRA AS18FDAHRA AS24FEAHRA Nederlands AS20S2SF2FA AS25S2SF2FA AS35S2SF2FA AS50S2SF2FA AS71S2SF2FA AS25S2SF2FA 1 AS35S2SF2FA 1 AS42S2SF2FA 1 AS50S2SF2FA 1 AS71S2SF2FA 1 AS20S2SF2FA 1 ...

Page 2: ...contacts should not be no less than 3mm Such means for disconnection must be incorporated in the Make sure installation is done according to local wiring regulation by professional persons A leakage explosion proof breaker must be installed Make sure ground connection is correct and reliable Read the precautions in this manual carefully before operating the unit This appliance is filled with R32 D...

Page 3: ...9 1 2 8 5 Contents PARTS AND FUNCTIONS OPERATION INDOOR UNIT INSTALLATION MAINTENANCE CAUTIONS TROUBLE SHOOTING 10 ...

Page 4: ...display 16 LOCK button Used to lock buttons and LCD display 25 RESET button When the remote controller appears abnormal use a sharp pointed article to press this button to reset 22 HOUR button Control the lightening and extinguishing of the indoor LED display board 8 9 QUIET button 11 COOL button 10 HEAT button 12 SWING LEFT RIGHT button 13 FAN SPEED button 14 TIMER button 15 HEALTH button 17 LIGH...

Page 5: ...for the first time and emergency operation starts the unit will run automatically in the following modes Room temperature Designated temperature Timer mode Fan speed Operation mode Above 23 o C Below 23 o C 23 o C 26 o C No AUTO AUTO COOL HEA T No It is impossible to change the settings of temp and fan speed It is also not possible to operate in timer or dry mode temperature is below 16 o C do not...

Page 6: ... won t be too high for your sleep The unit operaters in corresponding sleep mode adapted to the automatically selected operation mode O C O C futher After more another 3 hours temp O C 1O C O C if user resets Press button to enter additional options when cycle display to will flash And then press enter to sleep function 1 POWER Operation 2 QUIET Operation Note When you need rapid heating or coolin...

Page 7: ... electrical and electronic products conditioning system treatment of the refrigerant of oil and of other part must be done by a qualified installer in accordance with relevant local and national legislation Air conditioners must be treated at a specialized treatment facility for reuse recycling and recovery By ensuring this product is disposed of correctly you will help to prevent potential negati...

Page 8: ... disturbed Place possible to drain easily where piping can be conne cted with the outdoor unit Place where cold air can be spread in a room entirely Place nearby a power receptacle with enough space around Place where the distance of more than lm from televisions radios wireless apparatuses and fluorescent lamps can be left In the case of fixing the remote controller on a wall place where the indo...

Page 9: ...hem with the adhesive tape Left Left rear piping In case of left side piping cut away with a nipper the lid for left piping In case of left rear piping bend the pipes according to the piping direction to the mark of hole for left rear piping which is marked on heat insulation materials 1 Insert the drain hose into the dent of heat insulation materials of indoor unit 2 Insert the indoor outdoor ele...

Page 10: ...ring e r ror Faulty PCB Faulty EEPROM data Faulty EEPROM Faulty PCB Faulty connector connection Faulty therm istor Faulty PCB Room temperature sensor failure The power source must be exclusively used for air conditioner In the case of installing an air conditioner in a moist place please install an ea For installation in other places use a circuit breaker as far as possible Pipe cutting is carried...

Page 11: ...ndoor unit using vacuum cleaner or flaping them lightly otherwise its performance will be affected the cool and dry conditions For Smart Use of The Air Conditioner Replacement of Air Purifying Filter The white side of the photocatalyst air purifying filter face outside and the black side face the unit The green side of the bacteria killing medium air purifying filter face outside and the white sid...

Page 12: ...ITION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air occasionally especially when gas appliance is running at ...

Page 13: ...le ambient temperature range Specifications The machine is adaptive in following situation The power plug and connecting cable acquired the local 2 If the power supply cord is damaged it must be replaced manufacturer qualified person 4 The wiring method should be in line with the local wiring 5 After installation the power plug should be easily reached 6 The waste battery should be disposed proper...

Reviews: