background image

5

1

2
3

6

5

Remove all packaging components.

 

 

 

 

If need to bolster, choose
a stable, smooth setting
block, be sure to keep in
mind the foam base never
use for setting block.

Note: Product technical data reference each series of models

Clockwise rotation to increase the Beverage Chiller height.

Contrarotate to reduce the Beverage Chiller height.

D

W

d

c

b

a

H

4

Beverage Chiller open door size. 

(Unit: mm)

Cleaning the Beverage Chiller before use.

 

 

MODEL

a

b

c

d

LC-138WB

649

1037

1015

495

Above 10cm

Above 10cm

Above 10cm

L

Adjustable

H

PREPARATION BEFORE USE

Including thin film, box cover, foam base and fixed tape must be removed.

Well-placed, it’s better to clean the Beverage Chiller, use soft close to wipe the wine 

On standing

After installed and cleaned, please don’t power on right away, on standing at 
least 30 minutes, and then power on, to ensure normal operation.

Check the attachments and datum.

Check the contents according to the packing list.

Put the Beverage Chiller on the suitable position.

Don’t put on to cold environment.(less than 10°C)

Don’t put in the rain or outside the room.

Don’t put Beverage Chiller on the wet place or some places easy to splash, if 

wet use close to wipe, rust protection, influence on insulation performance.

Put Beverage Chiller keep away from the heat source, don’t direct sunlight, to 

avoid affecting performance.

If put the Beverage Chiller on the carpet, wood floor, the heat may distain the 

floor, so must mat interlayer.

Around the Beverage Chiller need to empty 10cm space to rejection of heat.

Put Beverage Chiller on the flat floor, if uneven floor Beverage Chiller running 

produces vibration and noise, cause failure. We can adjust the sole of the 

Beverage Chiller according to the floor flatness, decrease the vibration and 

noise.

Attention

Summary of Contents for LC-138WB

Page 1: ...OPERATION INSTRUCTION Keep it for your reference Product appearance depends on goods Beverage Chiller LC 138WB ...

Page 2: ...Infant care Air cooling Frostless Energy saving Mute Dry Store tea Ecological Orchard ...

Page 3: ...frost Energy saving mute High efficiency compressor and accurate temperature control with minimum noise Dry store tea Attractiveappearance Button switch for tea retain freshness mode control air output water and temperature Unique glass door with colorful crystal top surface designed toughened glass Ecological orchard Good temperature and clean air HCS preserve moisture sterilization technology exte...

Page 4: ... 3 5 8 7 9 10 12 Daily maintenance of product If you have any question please look here Technical data packing list 7 7 1 Beverage Chiller clean If you have any question please solve follow this section 9 2 Beverage Chiller moving 9 3 Beverage Chiller disuse 9 7 8 4 Cold storage temperature regulation key function 8 8 8 6 Sterilization function 8 8 8 7 Opening door alarm function 8 Power off memor...

Page 5: ... Prohibit dismantling the third prong of plug in any case its acts as the ground 1 Do not damage the power line Don t put the Beverage Chiller on the power line and don t step on the power line When clean the Beverage Chiller please be careful do not roll the power line 2 Do not brute force pulling power plug must hold the plug and then pull the plug 3 When the power line or plug is damaged must d...

Page 6: ...ing places 2 Farm hotel and motel residential guest 3 Family inn environment 4 Catering industry and similar applications 1 Avoid the children hanging play on the BeverageChiller door in case of door incline and topple to hurt people 2 When BeverageChiller pass into disuse please take down the door and Send it to the designated place for processing 1 Don t use water spray or wash the Beverage Chil...

Page 7: ...n standing at least 30 minutes and then power on to ensure normal operation Check the attachments and datum Check the contents according to the packing list Put the Beverage Chiller on the suitable position Don t put on to cold environment less than 10 C Don t put in the rain or outside the room Don t put Beverage Chiller on the wet place or some places easy to splash if wet use close to wipe rust...

Page 8: ...shelf Flat glass shelf Fruit box M Zone box Glass door USE STEPS FOR THE FIRST TIME PILOT RUN When power on don t put goods immediately after 30 minutes running open the glass door if there s a cooling effect the Beverage Chiller proper functioning WAITING FOR COOLING Before sufficient cooling try to keep door closed run empty for an house sufficient cooling put beverage normal use LED lamp Displa...

Page 9: ...esoutautomatically Whenthedisplayison pressthe lighting buttontolightupthelamp andpressthebuttonagain thelampgoesout Press the lock button keep for 3 seconds lock icon is off the panel is unlocked 2 Lock manually Press the lock button keep for 3 seconds lock icon is on the panel is locked 3 Auto lock Stop button operation for 30 seconds the panel locks and only lighting button can be operated othe...

Page 10: ...d dudu towarn Power off memory function Inthesituationofpoweroff thetemperatureisremembered whenrepoweron theBeverageChiller worksonthebasicofpreviouslysettingtemperature Display panel keep lighting function Inthesituationofunlocking press lighting buttonkeep10seconds the lighting button flickers 5times thedisplaykeepslightingup andthenpress lighting button keep10seconds the lighting button flickers 3...

Page 11: ...se follow material to clean 1 Organic and acid base solvent 2 Abrasive powder washing products 3 Stiff brush 4 Boiled water 1 Please take out all the food and pour out the water or ice of the ice making box 2 Use packaging tape to fix Beverage Chiller door shelves fruit box and so on to avoid damage during If Beverage Chiller is going to disuse long time please pull out plug power off and take out al...

Page 12: ...everage Chiller Feature Reason Solution Beverage Chiller inside temperature is not low enough 1 Setting temperature too high 2 Opening door frequently 3 Direct sunshine or near heat source Setting preference temperature close door well put on preference place Q5 Beverage Chiller glass door condensation Feature Reason Solution Glass door with condensation 1 Opening door frequently or door open for ...

Page 13: ...menon Feature Reason Solution Poop when working Temperature changes cause evaporator swell shrink Normal phenomenon Feature Reason Solution Bicker when working Liquid refrigerant flows Normal phenomenon Feature Reason Solution Noisy when working 1 Uneven ground 2 Beverage Chiller touches with wall or other objects 3 The packagings were not removed completely 1 Move Beverage Chiller to flat ground 2 ...

Page 14: ...e capacity LC 138WB ST Y 132 L 2 14 C 125 W 0 73 Kw h 24h 56kg 578 522 1075 mm 220 240 V 50 Hz LC 138WB Name Instruction Information kits Flat glass shelf Wine shelf Pcs Model 1 1 1 1 Power consumption Overall dimension D W H Weight LC 138WB Name Moisturizing lid Fruit box M Zone box Pcs Model 1 1 1 R600a Refrigerant Folded glass shelves 1 ...

Page 15: ......

Page 16: ...专用号条码 Verison V1 Date 201809 0070513173A ...