![Haier HYCD-282 Service Manual Download Page 12](http://html.mh-extra.com/html/haier/hycd-282/hycd-282_service-manual_2101645012.webp)
HYCD-282/282A/282C_Service Manual
12
Item
Steps
Display Msg
Unlock
1
、
press“
”for 5s
,
the refrigerator temp zone shows“F0”
Shows F0 and“0“bit
flash
2
、
short press“
”
,
the refrigerator temp zone shows“F1”
;
Shows ‘F1’
3
、
short press “
“
,
unlocked
。
No operation in 10s
,
it will auto lock
The lock light turn off
Alarm test
Unlock status
,
short press “
”
,
all the LED and indictor light will be
lighted for 6s
,
meanwhile
,
the speaker will buzz 6 times @1HZ
,
then all the
LEDs will show“8”for 6s.
All the LEDs show ‘8’
Lock status
,
short press “
”
,
the LEDs will show the alarm code.
Show the alarm cod
Parameters
Setup
1
、
Unlock status
,
short press“
”
,
The refrigerator temp zone will
show“L0”
,
“0”with flash
;
Show L0
,
“0”bit flash
2
、
short press“
“
,
adjust the parameters
;
L0~L5
3
、
short press“
”
,
the second bit flash
;
3
、
short press“
”adjust the bit of the LEDs
,
short press“
”to adjust
the value.
Notice
:
If the refrigerator temp zone show the temp and the freezer temp. zone shows“L0”
,
we need to
press“
“
,
then refrigerator temp. zone will show”L0“
;
when we want to adjust the parameter L0~L5
,
”we must change the ‘L0’to the temp zone that we need.
Compressor
Start delay
1
、
unlock status
,
press '
“and ”
“at the same time for at least 5s
,
the refrigerator temp. zone will show the delay time of compressor.
Show the value of
delay time
2
、
press “
“to adjust the parameter.
01~10
Notice
:
the freezer compressor begin to run after the refrigerator compressor works for 10s.
Calibrate
temp
1
、
unlock status
,
Press “
and “
” at the same time for 5s
,
the
refrigerator temp zone will show the value of the adjustment.
2
、
press“
“to adjust the value of the parameter
-5~+5
Notice
:
short press“
“
,
swap the parameter between refrigerator and freezer temp. zone.