Haier HYC-1378 Operation Manual Download Page 9

22

7

Normal operation will be impossible for refrigerator if it is installed in 

environments other than those described above as it is sensitive to ambient 

temperature. Start operation after the environment is improved.

Ambient temperature: 10

 to 32

, 18

 to 25

 are optimal and air conditioning system is 

required as necessary.
Ambient humidity: below 85%RH.

Avoid excessive dust.
Avoid mechanical swing or vibration.

The refrigerator shall operate at an altitude lower than 2000m.
Input voltage: no greater than ±10% of rated voltage.

It is prohibited to install the refrigerator outdoor. Electric leakage or shock may 

be caused if the refrigerator gets wet by rainwater.

The installation site shall meet following requirements for normal operation and best performance of 

refrigerator:

Do not install the refrigerator in a narrow and confined space and the door of the installation space 

may not be smaller or lower than the refrigerator, to ensure smooth entry and exit of the refrigerator 

as well as to prevent damage to the stored articles due to not timely repair of refrigerator as the 

installation site is not easy to be accessed.
The ground at the installation site shall be solid and flat.
It is well ventilated and free from direct sunshine.
Do not share one socket with plugs of other equipment and the plug shall be securely plugged into 

the socket.

Do not twist or compress the power line.
If the power line needs to be extended, the extended line shall be no smaller than 3mm² in 

sectional area and no longer than 3m.
Check the operating voltage before operation and voltage regulator appropriate for motor load may 

be applied in regions with unstable voltage.Ensure the normal input voltage stands at rated 

voltage ± 10% and the power of voltage regulator is greater than 4000W.
The refrigerator shall be grounded in a reliable manner.
If the socket is provided with grounding wire, check if it is well grounded before operation.
If the socket is not provided with grounding wire, a new one shall be installed by professional 

engineers.

Installation environment

Installation site

Do not ground the refrigerator through gas pipes, water supply pipes, telephone 

lines or lightning conductors as electric shock may be caused.
The power plug can be accessed after installation to ensure the power line can 

be pulled out in a timely manner in emergency cases. The air vent shall free from 

barriers.

Product Installation

Battery maintenance

When the refrigerator works continuously, please test battery charge level every 15 days (please 
refer to “Alarm Test” on Page 18 for test method). In case of low battery charge level, make sure 
that battery switch is on and battery is charged. When the battery has been charged for consecutive 
7 days, please retest battery charge level. In normal conditions, battery charge should be full. If low 
battery charge level remains, it is recommended to replace the rechargeable battery.The battery of 
power failure alarm is a consumable item with 3-year service life. If it has been used for more than 3 
years, power failure alarm may not act when alarm conditions occur. It is recommended to replace 
the battery earlier. Please contact a Haier after-sales service technician for battery replacement.

b.Battery removal
1)Pull out the plug from the power socket.
2)Screw off screws on the cover of electric cabinet with a screwdriver.
3)Pull out the battery's connecting plug.
4)Remove the battery's fixing clip and take out the battery.
5)Recycle or properly dispose the battery as required.

When replacing the battery, make sure that red wire is connected to the battery's positive pole 
and black wire to the battery's negative pole. Do not misconnect otherwise the charging circuit of 
computer board would be burned out easily and thus the battery cannot be charged.

The refrigerator has a built-in rechargeable battery. The battery is recyclable; when its service life 
expires,  please ask a local relevant battery recycling organization for check or discard it properly.
a.Battery location
The built-in battery of the refrigerator-freezer is used for power failure alarm and located in electric
cabinet.

There are high-voltage electrical components in electric cabinet.
To avoid electric shock, the cover of electric cabinet must be opened by a 
qualified engineer or maintener only.

Rechargeable battery recycling

Prohibition

Summary of Contents for HYC-1378

Page 1: ...haiermedical com Version 1st 2017 Dedicated code 0270501006 V13026 Read the Operation Manual carefully before using your appliance Keep the Operation Manual in a safe place Appearance color and layout of the door may vary Translation of the original instruction The scope of the Product Application Pharmaceuticals and other related products which need a storage environment of 2 8 Certificate of Qual...

Page 2: ...rator Manufactures Name Haier Medical and Laboratory Products Co Ltd Manufactures Address Haier Industrial Park Economic Technology Development Zone Qingdao 266510 P R China Refer to in this declaration confirms with the following directive s standards 2006 42 EC EN60335 1 EN60335 2 89 EN62233 HYC 1378 Haier Type Designation Trademark ...

Page 3: ...mpressor and main components and better refrigeration performance User friendly design computer control smart and carefree adjust ment not required High performance thermal insulation layer with excellent insulation effect Glass door with electric heat multiple anti condensation technologies Automatic evaporation of condensate water safety door latch We apologize that the Haier pharmaceutical refr...

Page 4: ...m the appliance that you have just purchased due to technical improvements 1 Product Feature Content Safety Precautions Precautions for Use Product Installation Component Names Control Panel Application method Alarm Cleaning and Maintenance FAQ Refrigeration Schematic Circuit Diagram Specification 2 3 6 7 12 14 18 21 23 24 26 Content ...

Page 5: ...plug in or pull out the power plug of refrigerator to prevent explosion and fire The refrigerator shall be installed by professional technical staffs or after sale maintenance staffs to prevent electric shock or fire Place the refrigerator on solid and flat ground in a stable manner The refrigerator will be tipped over or personal injuries will be caused if the refrigerator is placed on improper g...

Page 6: ...may pose danger to human health or environment Pull out the power plug if the refrigerator has been out of service for long time to prevent electric shock leakage or fire caused by aging power lines If the refrigerator is left unused in areas where supervision is unavailable for a long time make sure children will not get close to the refrigerator and the door can not be completely closed End of l...

Page 7: ...must be placed on a solid and flat surface or excessive vibration and noise may be produced when the appliance in operation The appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capacibilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and unders...

Page 8: ...s hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new ones the retailer is legally obligated to take back your old appliance for disposals at least free of charge Meaning of crossed out wheeled dustbin The refrigerator does not work Fault Troubleshooting Refrigeration effects are not apparent temp...

Page 9: ...tion site Do not ground the refrigerator through gas pipes water supply pipes telephone lines or lightning conductors as electric shock may be caused The power plug can be accessed after installation to ensure the power line can be pulled out in a timely manner in emergency cases The air vent shall free from barriers Product Installation Battery maintenance When the refrigerator works continuously...

Page 10: ...Downward upward Clean the back evaporating box Evaporating box is installed on the back of the refrigerator Remove 2 screws on the bottom loosen the upper 2 screws no need to remove them lift the evaporating box and take it out Clean the evaporating box Reinstall the evaporating box screw 4 screws firmly Clean the box every month If the refrigerator is used in high temperature and high humidity en...

Page 11: ...em is under normal condition When chargeable battery is closed or with too low a power press once the alarm testing key E6 is expected to flash 3 times on the display window at the simultaneously The refrigerator shall be charged by special personnel that inspects and records its operating conditions every day if too high or low a temperature is observed the articles in it shall be transferred to ...

Page 12: ...C220V 110V failed under any of the above conditions remote alarm shall be started Coupled with 1Hz continuous beeping Take corres ponding measures according to item 1 2 and 3 Remote alarm startup when beeping cancelled is pressed down both remove alarm and beeping are cancelled But if it remains alarming when after a period of Fd settable by the user the default value is 30 mins then beeping and r...

Page 13: ... upper or lower temperature displayed ALH Alarm Limit High settable by the user high temperature alarming is triggered while when any of upper or lower temperature shown ALL Aalrm LImit Low settable by the user low temperature alarming is triggered Display Requirements Remarks 1Hz Continuous beeping Alarm light flashing Temperature displayed Remote alarm startup when beeping cancelled is pressed d...

Page 14: ... inside temperature display area flashes Date press Minus button or Plus button to adjust the current date and the press Set button to save and confirm Thereafter the inside temperature display area shows Hour 4P if necessary press Set button to adjust if not press Plus button to Minute 5P for minute adjustment after completing settings press Set for 5s to save and exit then the inside temperature...

Page 15: ...re display area steadily shows 2P press Set button the inside temperature display area flashes Month factory default 01 press Minus button or Plus button select Month from 01 12 recycling display after selecting the current month press Set button to save and confirm Thereafter the inside temperature display area steadily shows 3P press Set button the inside temperature display area flashes Date fa...

Page 16: ...parameter value After setting press Set to go back and choose other parameters for the same token With all values set press Set button 5s exit and return to the normal display mode Temperature Display Application method The refrigerator can automatically reach the temperature set before ex factory Temperature Display 2 1 3 4 5 Operation Operating key Normal model Implications Plug and power on Swi...

Reviews: