Haier HYC-1099 Instruction Manual Download Page 29

27

Click the message and notepad button on the home page to enter the interface.

Leave a message

1.New message
It is used to create a new message. Click this button and a dialog box will pop up. Fill in the 

recipient, title and content and then send it.

Summary of Contents for HYC-1099

Page 1: ...YC 1099T HYC 1099F HYC 1099TF HYC 1099R Please read this manual carefully before using the appliance and keep the instruction manul for future use The company reserves the right to interpret this manual Product technology or software x is subject to upgrade without prior notice The product appearance may vary ...

Page 2: ...trol Panel 10 Control Specification LED Type Panel 15 Control Specification LCD Touch Panel 19 Display Alarms and Self Diagnonis 32 Product Maintenance 36 Recycle of Rechargeable Battery 37 Trouble Shooting 38 Refrigeration Principle and Circuit Diagram 39 Accessary Packing List 41 Cautions for Usage 45 ...

Page 3: ...by technicians approved by manufacturer Install the unit on a sturdy floor and take an adequate precaution to prevent the unit from turing over If the floor is not strong enough or the installation site is not adequate this may result in injury from the unit falling or tipping over Precautions for Safe Operation Grounding Symbol Shows Symbol for Manufacture Flammable material Failure to observe WA...

Page 4: ...circuit Do not place containers with water or heavy objects on the refrigerator If the object falls it may cause personal injury and the water flowing out may cause electric leakage or electric shock due to decreased insulation Do not ground the refrigerator through the gas pipe power hose telephone line or lightning rod The above grounding methods can cause electric shock or other dangers Do not ...

Page 5: ...nt gap or any outlet on the unit This may cause electric shock or injury by accidental contact with moving parts Check the setting when starting up of operation after power failure or turning off of power switch The stored items may be damaged due to the change of setting Once the refrigerator is powered off wait for at least five minutes before restart it so as to avoid damage to the compressor o...

Page 6: ...alarm sensor failure alarm door ajar alarm dirty condenser alarm Two alarm modes featuring audible buzzer and visible flashing light All individual components are safely grounded It is equipped with remote alarm network interface which is convenient and has reliable performance Multiple protection functions password protection overcurrent protection delay 3 Refrigeration system Inverter compressor...

Page 7: ...n part shall not be less than 2 mm2 and the length shall not be longer than 3 m Please check the working voltage before use For areas with unstable voltage a stabilizer that is suitable for motor load may be adopted for voltage regulating thus ensuring that the normal input voltage maintains at rated voltage 10 and the stabilizer power is greater than 4000W The refrigerator shall be reliably groun...

Page 8: ...ator to stand for more than 24 hours and then power it on to ensure that it can operate normally When handling the refrigerator before unpacking use forklift or package lifter When using a forklift insert the fork from the bottom of the wood pallet from front or back of the refrigerator and then handle the refrigerator When using a package lifter clip the machine from the bottom of the wooden pall...

Page 9: ...achine body 8 Installation of drawer slides and drawers optional First insert the rear end of the drawer slide into the rear shelf bar and then insert the front shelf bar at the front side and fix it with M4 screws as shown in Fig 1 on the right Next push the drawer into the machine box along the direction of the slide as shown in Fig 2 on the right Fig 1 Fig 2 9 RFID antenna HYC 509R 1099R Take o...

Page 10: ...ches 2 C 8 C The temperature of the refrigerator can be stabilized at 2 8 C after a few hours of running Switch on the refrigerator and turn on the power switch on the electric control box on the right side of it The alarm buzzer sometime operates which is normal The refrigerator is set to operate at 5 C at the factory There is no need to change the control settings Turn on the light switch to che...

Page 11: ...d for storing products Do not load in too much warm product at one time Overloading the refrigerator will reduce the system s expected life Therefore product and samples should be placed into the refrigerator in batches Do not damage the refrigeration circuit Do not use unlicensed appliances inside the refrigerator The refrigerator has memory of the set values In case of power on after power failu...

Page 12: ...ation for HYC 509T 509R and optional for HYC 509 The control panel of HYC 509T is LCD screen and that of HYC 509 509R is LED screen Refrigerator Components Caution Shelf Drawer optional Caster Leveling leg Mechanical lock Electromagnetic lock USB interface Handle NFC reader Control panel Touch panel Only for HYC 509R ...

Page 13: ...e Handle NFC reader Control panel Mechanical lock Electromagnetic lock Electromagnetic lock and NFC function is standard configuration for HYC 509TF and optional for HYC 509F The control panel of HYC 509TF is LCD screen and that of HYC 509F is LED screen Caution ...

Page 14: ...ndard configuration for HYC 1099T 1099R and optional for HYC 1099 The control panel of HYC 1099T is LCD screen and the control panel of HYC 1099 1099R is LED screen Mechanical lock Electromagnetic lock USB interface Handle NFC Drawer optional Control panel Caution Touch panel Only for HYC 1099R ...

Page 15: ...USB interface Handle NFC Control panel Electromagnetic lock Electromagnetic lock and NFC function is standard configuration for HYC 1099TF and optional for HYC 1099F The control panel of HYC 1099TF is LCD screen and the control panel of HYC 1099F is LED screen Caution ...

Page 16: ...14 LED Type Panel HYC 509 509F 509R 1099 1099F 1099R LCD Touch Panel HYC 509T 509TF 1099T 1099TF Control panel LCD Touch Panel LED Type Panel ...

Page 17: ...ously once it is pressed and the alarm indicator light flickers 3 times in synchronization In the case of faults each fault code is displayed in turn for 1s and the light is OFF for 1s button it is used for control of the light inside the refrigerator The status of the light will change when it is pressed each time The parameters of the refrigerator have been set before delivery It is recommended ...

Page 18: ...ement level password modification 000 999 1 008 CL1 IC card logout all IC cards Press the Set button 000 flickers and it requires to enter the registration password Enter the correct password and then press Set to execute the order The CL1 flickers for 3 times and there is a buzz sound which means that the logout is completed If you enter the wrong password for 3 times in a row it will exit and re...

Page 19: ...the buzzer will make three short sounds to prompt the user that the electromagnetic lock cannot be opened Press or to select the parameter to be modified press Set to enter the selected parameter and the present parameter value will flickers and then adjust the parameter by or After completion of setting press Set to confirm and save After completion of parameter setting press the Alarm Test butto...

Page 20: ...factory default 01 Press the Down button or the Up button and the value will switch over from 00 to 23 After selecting the current local time hour press the Set button to save and confirm After that the inside temperature display area displays P5 steadily Press the Set button and the inside temperature display area will flicker and display the minute factory default 01 Press the Down button or the...

Page 21: ...kers Click it to clear the buzzer alarm If there is no buzzer alarm the icon displays normally Click this icon to perform the alarm test and the buzzer shall make three sounds Click it to enter the curve view page to download the temperature record Click it to enter the information query interface Click it to enter the settings interface It indicates that the network is enabled It indicates that t...

Page 22: ...lso choose 2h View 24h View 7day view 1month view or enter the starting and end times to view When the selected time period exceeds one month the curve cannot be viewed Download You can enter the starting and end times and plug in an USB to download the temperature data If no selected time period it will download all the data by default This interface has five query buttons including event record ...

Page 23: ...closing setting changes data upload and download and account login record Enter the starting time and end time to query the records in this time period Click download to download the event log via an USB The ozone sterilization function is reserved and is not enabled Caution ...

Page 24: ...wer supply battery and sensor failure alarm It also can be used to query the alarm record information in a certain period of time The alarm record information can be downloaded via an USB 2 Battery power It can be used to check the input voltage output voltage and battery level of the battery ...

Page 25: ...uration file and database information 4 Operational status It can be used to query information such as the ambient temperature set temperature voltage and cumulative running time of the compressor and fans and also running status of main parts such as the compressor internal and external fans green indicates running gray indicates not running ...

Page 26: ...erational setting network setting not enabled and user setting Settings 1 Temperature high low alarm setting it can be used to set the temperature inside the refrigerator as well as the high temperature and low temperature alarm values Adjust he value by clicking and and click Save to complete setting ...

Page 27: ...de up and down to select the value and then click Save to complete setting 3 Operational settings The interface can be used to adjust the alarm volume screen brightness operational mode screen sleep time period screen saver time period buzzer alarm delay time curve default display range lock screen time light delay turn off time and other information ...

Page 28: ...on while cannot set the refrigerator parameters and administrator mode in the licensing mode only the administrator is able to change the refrigerator settings use all the refrigerators function and switch the licensing mode to normal mode Fingerprint When using a fingerprint password lock optional click the fingerprint registration and a fingerprint registration prompt will pop up After completin...

Page 29: ...d notepad button on the home page to enter the interface Leave a message 1 New message It is used to create a new message Click this button and a dialog box will pop up Fill in the recipient title and content and then send it ...

Page 30: ...sage information in outbox and inbox Enter the starting and end times to query the message information during this period 3 Note board You can create and view the notepad You can modify and update the previous note content in the pop up interface after clicking it directly ...

Page 31: ...ing device which can transmit the temperature data and alarm information of the refrigerator to the designated server For the specific functions please refer to the user manual of the remote monitoring device attached to this manual Remote Temperature Monitoring Device ...

Page 32: ...total amount and the distribution of expiry date and can also be used to realize the whole machine inventory count and out put in storage query through the stock count and out put in storage record buttons HYC 509R 1099R RFID Touch Screen Operating Instructions HYC 509R 1099R is equipped with electronic door lock which can be unlocked by swiping the NFC card After closing the door the electronic d...

Page 33: ...erminal security management software security software should be able to ensure the effective version of the computer system security The production environment is as follows The name of the software Specifications and Models Full Version Supplier Operating Environment Requirements Rising enterprise terminal security management software 25 00 05 05 25 00 05 05 Beijing Rising Network Security Techn...

Page 34: ...ndenser is too dirty and needs to be cleaned in time Network indicator light when the light is ON it indicates that it is in the networking state during communicating the light flickers NFC indicator light when the light is ON it indicates that the NFC card reading board is connected when the light is OFF it indicates that the NFC recording board is not connected when the light flickers it indicat...

Page 35: ...rs and the digital tube alternately displays the temperature and fault code Makes intermittent alarm sound Start up Ambient temperature and humidity sensor fault alarm E12 Ambient temperature and humidity sensor fault The alarm light flickers and the digital tube alternately displays the temperature and fault code Makes intermittent alarm sound Start up Condenser sensor fault alarm E13 Condenser s...

Page 36: ...ed spare battery will keep the alarm function active for 12 hours LCD 48 hours LED After starting the refrigerator for the first time or after a long period of power failure the refrigerator needs to run for 2 days to fully charge the battery Press the Alarm Test button and each time the buzzer make sounds for 3 times at frequency of 1Hz and the alarm light flickers for 3 times If it is not in the...

Page 37: ...nd normally closed functions In the case of the external power failure the remote alarm can be activated regardless of whether the battery switch is turned on The remote alarm interface works in combination with the audible alarm on the refrigerator Therefore pressing the buzz cancel button can only clear the alarm sound while the remote alarm status remains unchanged Caution ...

Page 38: ... long service life If there is any abnormality please contact the after sales service personnel for replacement If the refrigerator needs to be left used for a long time cut off the power and switch the battery switch to terminal O Open the door of the refrigerator and take out the inner shelves or drawers Clean the refrigerator thoroughly Clean the shelves or drawers After the refrigerator and sh...

Page 39: ...y as specified There are high voltage electrical components in the electric cabinet To avoid electric shock only qualified engineer or maintenance personnel are allowed to open the cover When replacing the battery make sure that the brown wire is connected to the anode of the battery and the blue wire is connected to the cathode It must not be reversed Otherwise the computer board charging circuit...

Page 40: ...ure is too high If the air duct is blocked Excessive noise If the refrigerator is placed firmly If any part of the machine body contact with external objects or the wall The noise indicated in the technical data is the average data measured at 1 m from the surface in a standard laboratory without noise by placing an empty refrigerator on the rubber mat closing the door and waiting for stable opera...

Page 41: ...39 Refrigeration principle and circuit diagram Refrigeration schematic diagram Compressor Evaporator Dry filter Capillary tube Condensor Exhaust pipe Suction tube ...

Page 42: ...n Evaporator fan 3 Evaporator fan 2 Evaporator fan 1 Transformer Door heating wire Cabinet opening heating wire Mullion heating wire Frequency converter Compressor Anti low temperature mechanical thermostat Transformer Water pan heating wire Temperature limiter Filter Master power switch Live wire Neutral lin e Ground wire Note Evaporator fan 3 and mullion heating wire in the dashed line boxes are...

Page 43: ... 40dB A 40dB A 40dB A 40dB A Rated power supply 220 240V 50 60Hz Rated power current 370W 1 85A 315W 1 75A 400W 2A Power consumption 5 9kW h 24h 5 3kW h 24h 6 0kW h 24h Electric protection type I NFC card Optional Standard Optional Standard Standard USB function Standard Standard Standard Standard Standard Alarm type High low temperature alarm sensor fault alarm door ajar alarm hot condenser alarm...

Page 44: ... 330kg 340kg Noise level 43dB A 43dB A 43dB A 43dB A 43dB A Rated power supply 220 240V 50 60Hz Rated power current 470W 2 5A 440W 2 25A 500W 2 7A Power consumption 6 8kW h 24h 6 0kW h 24h 7kW h 24h Electric protection type I NFC card Optional Standard Optional Standard Standard USB function Standard Standard Standard Standard Standard Alarm type High low temperature alarm sensor fault alarm door ...

Page 45: ...4 3 4 3 NFC card 0 5 0 5 5 Stop support 2 2 2 2 2 Shelf 6 6 6 6 6 Price tag 6 6 6 6 Name HYC 1099 HYC 1099T HYC 1099F HYC 1099TF HYC 1099R Operation manual 1 1 1 1 1 Factory inspection report 1 1 1 1 1 Mechanical lock electromagnetic lock keys 8 0 8 6 8 0 8 6 8 6 NFC card 0 5 0 5 5 Stop support 2 2 2 2 2 Shelf 12 12 12 12 12 Price tag 12 12 12 12 Accessory Packing List ...

Page 46: ...C 509TF 220 240 50 60 0 0015 HYC 509R 220 240 50 60 0 0015 HYC 1099 220 240 50 60 0 0026 HYC 1099T 220 240 50 60 0 0026 HYC 1099F 220 240 50 60 0 0026 HYC 1099TF 220 240 50 60 0 0026 HYC 1099R 220 240 50 60 0 0026 This product contains fluorinated greenhouse gases covered by the Kyoto Protocol Do not vent into the atmosphere GWP global warming potential Refrigerant type GWP R600a 20 ...

Page 47: ...ctuations of temperature and humidity inside the refrigerator After opening the door the chamber temperature will rise sharply for a short time this phenomenon is normal and the temperature will generally recover within 1 hour after closing the door The ambient temperature for application of this product is 16 32 C and the humidity shall be below 85 In high temperature and high humidity environmen...

Page 48: ...iomedical Co Ltd Address Haier Industrial Park Economic Technology Development Zone Qingdao P R China Web www haiermedical com Revision Date 11 2019 Version 1st 2019 Dedicated code 0270501769 V13026 Certificate of Quality checker ...

Reviews: