Haier HW-WA101DBT Operation & Installation Manual Download Page 5

4

The black terminal of the controller communication line is connected with the black 

harness terminal at the lower outgoing line port of the unit� The other end of the controller 

communication line is pressed on the wiring base of the controller, and the corresponding 

relationship is red~+12V, black~GND, green~A2 and white~B2�
Connection terminal between controller communication line and IDU:

The Split IDU

Controller

All of the power supply and communication 485 cables between each module and terminal 

module to the controller are double core shielded twisted-pair cable. Specific wiring as the 

table below:

Controller

12V

- black

12V+ red

Controller Installation

The communication line is connected with the controller

The length of signal line

Wiring dimension

≤100m

0�75mm

2

×4

Fix the screw through the bracket on the 86 cassettes and connect the connection� The red 

connects to the +12V and black to GND, the green connects to A2, and the white connects 

to B2. Please pay attention to the line order. Then the controller is fixed down.

Notes:

1� B1 and A1 are unavailable�

2� B2 and A2 for 485 interface, access to split unit's 485 B and A, paying attention to line 

order�

3� ARALM1 and ALARM2 factory default is connected, if not be connected, then the main 

interface of the controller will display alarm information, and all indoor units will be turned off.

Summary of Contents for HW-WA101DBT

Page 1: ...on for controller 1 Controller Installation 3 Split Controller Operation Installation Manual Please read this operation manual before using the wired controller Please keep this manual carefully and safely HW WA101DBT Ver A ...

Page 2: ... controller Check whether the controller software is normal Display Touch area Restart button Press to restart controller Check whether the controller chip is normal Hanger hole Hanger hole Power 12V DC Fire alarm linkage contact Reserved Third party interface Reserved Communication port ...

Page 3: ...M2 Short circuit the ALARM1 and ALARM2 Reserved port Third party interface B1 A1 A1 485 B1 485 Reserved port Communication port B2 A2 It is used for connecting converter please pay attention to A2 485 B2 485 Note B1 A1 are unavailable to the Split Controller B2 A2 are available Part information for controller ...

Page 4: ...hat can produce noise Don t install in wet locations It will cause failure if you install in a place that shakes violently Don t install in the place where it is exposed to direct sunlight or near to the heat This will cause failure Installation condition Controller Installation First attach the mounting plate to the wall Using a job box is preferred Use A and B holes for an 86mm box use C and D h...

Page 5: ...le Specific wiring as the table below Controller 12V black 12V red Controller Installation The communication line is connected with the controller The length of signal line Wiring dimension 100m 0 75mm2 4 Fix the screw through the bracket on the 86 cassettes and connect the connection The red connects to the 12V and black to GND the green connects to A2 and the white connects to B2 Please pay atte...

Page 6: ...ub and you can only use this controller to view the unit parameters not to control the unit operation status Controller Installation Installation settings Tap on menu icon in main interface SETTING INSTALLATION Enter the correct password 841226 go into the installation interface Please refer to the installation manual of the indoor unit for specific operation methods Please refer to the installati...

Page 7: ......

Page 8: ...Qingdao Haier Air Conditioner Electric Co Ltd Haier Industrial Park Qianwangang Road Eco Tech Development Zone Qingdao 266555 Shandong China ...

Reviews: