11
12.Equipment operation
(
1).Check if the compressor and the fan are functional when the equipment is powered on and
operated. The cooling time of each refrigerator (freezer) varies due to the service environment.
Generally, the inner temperature of the refrigerator can be dropped to (+2
℃
to +8
℃
) in 4-5 days.
The vaccine can be stored in the refrigerator at such temperature and the vaccine must be loaded
in the vaccine basket (or the rack).Cover the internal and the external door.
(2).Please observe the temperature change displayed on the freezing display of the refrigerator
(freezer) with the freezer. When the temperature is reaches -5
℃
and below, the ice raft can be
loaded.
Caution
This refrigerator (freezer) is powered by the solar energy. Once the sunlight reaches the
specified intensity, the machine is driven. It can be normally operated after several starting
attempts.
The compressor can be started and stopped with the weather, in case the weather is variable.
Do not connect to any unqualified power supply.
The display on the door cover is also driven by the solar energy rather than any other power
supply means. The temperature display or the screen flicker may be unavailable when the
light is weak. The real-time inner temperature is displayed when the screen is radiated by a
flashlight or other light sources for about 3s. The screen will recover to the original status
when the light source is gone.