Domestic Air Conditioner
5.3 Function of Main Thermistor
Note
:
A:Outdoor suction temperature sensor
B: Exhaust temperature sensor
C: Indoor heat-exchange sensor
Outdoor Suction Temperature Sensor
The outdoor heat exchanger thermistor is used for controlling target discharge temperature.
The system sets a target discharge temperature according to the outdoor and indoor heat
exchanger temperature, and controls the electronic expansion valve opening so that the
target discharge temperature can be obtained.
Exhaust Temperature Sensor
The discharge pipe thermistor is used for controlling temperature of the discharge pipe.
If the temperature of discharge pipe (used in place of the inner temperature of the
compressor) rises abnormally, the operating frequency drops or the operation halts.
Indoor heat-exchange sensor
1.The indoor heat exchanger thermistor is used for controlling target discharge temperature.
The system sets a target discharge temperature according to the outdoor and indoor heat
exchanger temperature, and controls the electronic expansion valve opening so that the
target discharge temperature can be obtained.
2.The indoor heat exchanger thermistor is used for preventing freezing.During the cooling operation, if
the temperature drops abnormally, the operating frequency becomes lower, then the operation halts.
3.The indoor heat exchanger thermistor is used for anti-icing control.During the cooling operation, if
the heat exchanger temperature in the room where operation is halted becomes -1°C, it is assumed
as icing.
HSU12/18VHJ(DB)
30
Summary of Contents for HSU18VHJ(DB)
Page 3: ...12 VHJ DB 101 101 102 106 ...
Page 18: ...Domestic Air Conditioner PCB 2 CN1 CN2 CN3 CN4 CN5 CN6 CN7 CN11 CN10 15 HSU12 18VHJ DB ...
Page 21: ... Domestic Air Conditioner PCB 2 CN1 CN2 CN3 CN4 CN5 CN6 CN7 CN11 CN10 18 HSU12 18VHJ DB ...
Page 95: ...Loosen the top panel screws 1 2 Lift the top panel HSU12 18VHJ DB Removal Procedure 92 ...
Page 97: ...9 3 2 Removal of Electrical Box HSU12 18VHJ DB Removal Procedure 94 ...
Page 98: ...9 3 3 Removal of Fan and Fan Motor HSU12 18VHJ DB Removal Procedure 95 ...
Page 99: ...2 Loosen the fixing screws and remove the motor HSU12 18VHJ DB Removal Procedure 96 ...
Page 100: ...9 3 4 Removal of fan motor Bracket and Partition HSU12 18VHJ DB Removal Procedure 97 ...
Page 101: ...and remove the reactor Loosen the screw HSU12 18VHJ DB Removal Procedure 98 ...
Page 104: ... SSHQGL SSHQGL 3LSLQJ LDJUDPV 68 9 101 ...