7.Codes and Description
7.1.Problem Symptoms and Measures
Symptom
Check Item
Details of Measure
Check the power supply.
Check to make sure that the rated voltage is
supplied.
None of the
units operates
Check the indoor PCB
Check to make sure that the indoor PCB is
broken
Equipment
operates but
does not cool,
or does not
heat (only for
heat pump)
Diagnosis by service
port pressure and
operating current.
Check for insufficient gas.
Large
operating
noise and
vibrations
Check the installation
condition.
Check to make sure that the required spaces
for installation (specified in the Technical Guide,
etc.) are provided.
7.2 Error Codes and Description indoor display
Code indication
indoor
Description
E1
Room temperature sensor failure
E2
Heat-exchange sensor failure
E4
Indoor EEPROM error
Indoor Malfunction
E14
Indoor fan motor malfunction
The code indication that is listed above is the main fault
Trouble shooting
Caution
Be sure to turn off power switch before connect or disconnect connector, or else parts damage may be
occurred.
E1: Room temperature sensor failure CN8
E2: Heat-exchange sensor failure CN8
Summary of Contents for HSU18VCK
Page 1: ...ON OFF EK Series Model No HSU24VCK Order No AC1101S008V0 2011 ...
Page 3: ...HSU24VCK SM Table of Contents ...
Page 43: ...948 840 340 41 HSU24VCK SM 10 4 Outdoor Unit ...
Page 44: ...42 HSU24VCK SM ...
Page 45: ...43 HSU24VCK SM 320 1147 261 948 340 840 ...
Page 46: ...44 HSU 9 CK HSU24VCK SM ...