Drawing for the installation of indoor and outdoor units

Necessary Tools for Installation

Hammer

ƽ

Torque wrench

ƽ

(17mm,22mm,26mm)

Nipper

ƽ

Reamer

ƽ

Hacksaw

ƽ

Pipe cutter

ƽ

Gas leakage detector or

ƽ

soap-and-water solution

Hole core drill

ƽ

Flaring tool

ƽ

Spanner(17,19 and 26mm)

ƽ

Knife

ƽ

Measuring tape

ƽ

ƽ

ƽ

ƽ

ƽ

ƽ

Place where the distance of more than lm from televisions, radios, wireless apparatuses
and fluorescent lamps can be left.

ƽ

In the case of fixing the remote controller on a wall, place where the indoor unit can
receive signals when the fluorescent

ƽ

lamps in the room are in use.

ƽ

ƽ

Place, where discharged wind and noise do not cause a nuisance to the neighbors.

ƽ

Place, where a distance marked

ƽ

Q

is available as illustrated in the above figure.

Before inserting power plug into receptacle, check the voltage without fail.
The power source is the same as the

ƽ

corresponding name plate.

Install an exclusive branch circuit of the power.

ƽ

A receptacle shall be set up in a distance where the power cable can be
reached. Do not extend the cable by cutting it.

ƽ

Selection of Installation Place

Power Source

Preparation

NO.0010536243

Installation Manual of Room Air Conditioner

The models adopt HC FC free refrigerant R410A

Indoor Unit - Select a plocation that is

Outdoor Unit - Select a plocation that is

Robust not causing vibration, where the body can be supported sufficiently.

Not affected by heat or steam generated in the vicinity, where inlet and outlet of the 
unit are not disturbed.
Possible to drain easily, where piping can be connected with the outdoor unit.

Where cold air can be spread in a room evenly.

Nearby a power receptacle. (Refer to drawings).

Not less affected by rain or direct sunlight and is sufficiently ventilated.
Strong enough to bear the unit, where vibration and noise are not increased.

Please be subject to the actual product purchased , the above picture is just for your reference.

Read this manual before installation
Explain suf ciently the operating means to the user according to this manual.

Optional parts for piping

Non-adhesive tape

Adhesive tape

Saddle (L.S) with screws

Connecting electric cable

for indoor and outdoor

Drain hose

Heating insulating material

Piping hole cover

Floor xing dimensions of the

outdoor unit (Unit:mm / inch)

Fixing of outdoor unit

Fix the unit to concrete or block

with bolts (10mm) and nuts rmly

and horizontally.

When tting the unit to wall

surface, roof or rooftop, x

a supporter surely with nails

or wires in consideration of 

earthquake and strong wind.

If vibration may affect the

house, x the unit by attaching a 

vibration-proof mat.

The marks from

to

in the gure are the

parts numbers.
The distance between
the indoor unit and the

oor should be more

than 2m.

more than 10cm

more than 10cm

more than 10cm

more than 20cm

more than 15cm

more than 25cm

more than 60cm

A

G

A

F

C

E

D

G

B

Arrangement of piping
directions

Rear left

Left

Rear
right

Right

Below

Attention must be paid to

the pitch of drain hose

A

C

184

580

184

0

8

3

For:

HSU24VCK-W

(3 7/8)

(3 7/8)

(3 7/8)

(7 7/8)

(23 5/8)

(9 7/8)

(5 7/8)

(4 1/2)

For:HSU18VCK-W

(24 7/8)

(4 1/2)

(13 1/2)

113.5

113.5

633

340

(14 15/16)

(7 1/4)

(22 7/8)

(7 1/4)

Summary of Contents for HSU18VCK

Page 1: ...f the unit are not disturbed Possible to drain easily where piping can be connected with the outdoor unit Where cold air can be spread in a room evenly Nearby a power receptacle Refer to drawings Not less affected by rain or direct sunlight and is sufficiently ventilated Strong enough to bear the unit where vibration and noise are not increased Please be subject to the actual product purchased the ...

Page 2: ...pull it out on the front side then connect them 3 Coat the flaring seal face with refrigerant oil and connect pipes Fixing the indoor unit body ƽ In order to fix the body onto the mounting plate hold up ƽ the body aslant from the underside and then put it down perpendicularly Connecting the indoor outdoor Electric Cable Removing the wiring cover Remove terminal cover at right bottom corner of indoor...

Page 3: ...7m Max Length Bmax 5m In case the pipe length B is more than 10m the refrigerant should be charged according to 50 g m 3 Connection If the drain elbow is used ƽ please attach it as figure Note Only for heat pump unit Detach the service port s cap of 1 3 way valve the valve rod s cap for 2 way valve and 3 way s connect the service port into the projection of charge hose Iow for gaugemanifold Then co...

Page 4: ...se ƽ apply heat insulation to Less than 5cm confirm that drainage it without fail 4 Check Items for Test Run Put check mark in boxes Gas leak from pipe connecting Heat insulation of pipe connecting Are the connecting wirings of indoor and outdoor firmly Is the connecting wiring of indoor and outdoor firmly fixed Is drainage securely carried out Is the earth line securely connected Is the indoor unit s...

Page 5: ... la unidad no cause una molestia a los vecinos Coloque la unidad en un lugar en el que pueda disponerse de la distancia de separación marcada en la figura anterior Herramientas necesarias para realizar la instalación Fuente de alimentación Selección del lugar de instalación diagrama de instalación de unidades interiores y exteriores Los modelos cumplen la norma R410A sobre refrigerantes libres de H...

Page 6: ...con la posición del orificio en la pares Tenga cuidado de no romper los tubos al doblarlos Conecte previamente el cable eléctrico de interior exterior y tire de la conexión al aislante de calor del componente de conexión Conexión de los cables eléctricos de interior exterior Accesorios Selección de tubo Al fijar por primera vez la placa de montaje Al montar la placa de montaje fijándola a una barra l...

Page 7: ... 7m 27 9 16 se verán afectadas las funciones de la unidad Si es necesario alargar el tubo deberá cargarse refrigerante adicional a razón de 50 g m 0 045 oz pulgada No obstante la carga de refrigerante deberá ser realizada por un ingeniero profesional en aire acondicionado Antes de añadir refrigerante adicional realice una purga de aire desde los tubos refrigerantes y la unidad interior utilizando ...

Page 8: ...nvernadero regulados por el Protocolo de Kioto B Carga de refrigerante que contiene el producto de fábrica consulte la placa de características de la unidad C Cantidad de refrigerante adicional cargada durante la instalación D Carga total de refrigerante E Unidad exterior F Botella de refrigerante y colector de carga Prueba de instalación y ejecución de la prueba Explique al cliente cómo utilizar ...

Page 9: ...acement où le vent et le bruit ne risquent pas de gêner les voisins Choisir un endroit dans lequel les distances marquées illustrées dans le schéma ci dessus sont disponibles Outillage requis pour l installation Source d alimentation Sélection de l emplacement pour l installation schéma d installation des unités intérieures et extérieures Les modèles utilisent le réfrigérant R410A sans HCFC Dispos...

Page 10: ...le pour la tuyauterie en fonction de la direction de la tuyauterie et cintrez ensuite le tuyau selon la position du trou dans le mur Lors du cintrage prenez soin de ne pas écraser les tuyaux Connectez au préalable le câble des unités intérieures extérieures et recouvrez ensuite les câbles connectés avec l isolation Connexion du câble des unités intérieures extérieures Accessoires Sélection du tuya...

Page 11: ... entrés dans le tuyau La longueur standard du tuyau est de 7 m 27 9 16 Au delà de 7 m 27 9 16 l unité ne fonctionnera pas correctement S il faut rallonger le tuyau le réfrigérant doit être chargé selon 50 g m 0 045 oz pouce Toutefois la charge de réfrigérant doit être exécuté par un professionnel de la climatisation Avant d ajouter du réfrigérant purgez l air des tuyaux de réfrigération et de l un...

Page 12: ...unité voir sur la plaque signalétique de l unité C Quantité supplémentaire de réfrigérant chargée sur place D Charge totale de réfrigérant E Unité extérieure F Cylindre réfrigérant et collecteur de chargement Vérification de l installation et test de fonctionnement Expliquez le fonctionnement à vos clients en vous servant du manuel Cochez les cases 9 Fuite de gaz dans le raccordement du tuyau Isola...

Reviews: