CONTROLLER FEATURES & SETTINGS

PAGE 4

ENGLISH

Note:
1. After setting the intelligent airflow function, the louver 
position is fixed.
2. In cooling, it is better to select the

 mode.

3. In heating, it is better to select the

 mode.

4. In cooling and dry modes, using the air conditioner for a
long period of  time under high humidity conditions, con-
densate water may form on the grille/louver.

E) Right and left airflow setting

This will adjust the left and right airflow of the unit. Press 
the Extra Function 

(;75$

)81&7,21

 

button until 

 is displayed. This 

will adjust the left and right positioning of the louvers. 
Press the Confirm/Cancel 

&21),50

&$1&(/

 button to apply the set-

ting. 

F) A-B Yard 

- This will allow you to control two seperate units 

with a single remote control. 
Note: this feature would be setup at the time of installation 
by the contractor.

G) 50°F low temperature heating 

- Feature not available on 

this series.

 

H) Sleep mode

Press the Extra Function 

(;75$

)81&7,21

 button to enter additional 

options, cycle the button to display the

 icon, the 

icon will  flash. Press the Confirm/Cancel 

&21),50

&$1&(/

 button to 

enter the sleep function.

Sleep Operation Mode
1. SLEEP mode during COOL, DRY modes 
One hour after SLEEP mode starts, the temperature will 
rise 2°F above   set temperature, after another hour, the 
temperature rises an additional 2°F. The unit will run for an
additional six hours, then turns  off. The final temperature 
is 4°F higher than the initial set temperature. Using this 
feature will help with achieving maximum efficiency and 
comfort from your unit while you sleep.

SLEEP operation starts

SLEEP operation stops

Approx.6hrs

1 hr

Rises 2

O

F

Rises 2

O

F

Temp.setting

Unit stop

In COOL, DRY mode

1 hr

2. SLEEP mode during HEAT mode 
One hour after SLEEP mode starts, the temperature will 
decrease 4°F below set temperature, after another hour, 
the temperature will decrease an additional 4°F. After an 
additional three hours, the temperature will rise by 2°F. 
The unit will run for an additional three hours, then turns 
off. The final temperature is 6°F lower than the initial set 
temperature. Using this feature will help with achieving 
maximum efficiency and comfort from your unit while you 
sleep.

SLEEP

operation starts

SLEEP

operation stops

1 hr

1 hr

3 hrs

3 hrs

Rises 3

O

F

Temp.setting

Unit stop

In HEAT mode

Decreases 4

O

F

Decreases 4

O

F

3. In AUTO mode
The unit operates in corresponding sleep mode adapted 
to the automatically selected operation mode.

 Note:

When the unit is set to sleep mode, the fan speed will be 
set to low speed and cannot be changed.

Note: When the TIMER function is set, the sleeping 
function cannot be set. If the sleeping function has been 
set, and the user sets the TIMER function, the sleeping 
function will be canceled, and the unit will be set to the 
timer function.

I) Electrical heating 

-

 

Feature not available on this series.

J) Refresh air 

-

 

Feature not available on this series.

K) Turbo

Use this function when rapid heating or cooling is needed.

Press the EXTRA FUNCTION 

(;75$

)81&7,21

 button to enter 

additional options, cycle the button to display the 
icon, the 

 icon will flash. Press the CONFIRM/CANCEL 

&21),50

&$1&(/

 button to enter the power function. To cancel the 

power function, press the EXTRA FUNCTION 

(;75$

)81&7,21

 button 

again to enter additional options , press the CONFIRM/
CANCEL 

&21),50

&$1&(/

 button or select a different mode to cancel 

the power function.

Note:
During POWER operation, in rapid HEAT or COOL mode, 
the room may have uneven temperature distribution.

L) Fahrenheit/Celsius mode shift on unit and remote 

-

To switch between Fahrenheit and Celsius press the EXTRA 
FUNCTION 

(;75$

)81&7,21

 button until either Celsius or Fahrenheit is 

displayed. Press the CONFIRM/CANCEL 

&21),50

&$1&(/

 button to apply 

the change.

13

 

HEALTH Button

Feature not available on this series.

14

 

Confirm/Cancel Button

Function: Setting and canceling timer and other functions.

15

 

LOCK Button

Used to lock buttons and LCD display

16

 

LIGHT Button

Turns indoor unit display on and off

Summary of Contents for HSU12VHGDB-G

Page 1: ...ormalities such as a burnt smell are found immediately power off the main switch and contact a licensed contractor Do not obstruct or cover the ventilation grille on the air conditioner Do not put fingers or any other things into the inlet outlet or swing louver Do not allow children to play with the air conditioner Children should never be allowed to sit on the outdoor unit Please read this manua...

Page 2: ...ng to room temperature The will be displayed during HEAT mode 5 DRY Button DRY mode is used to reduce humidity In DRY mode when room temperature becomes lower than temp setting 2 F unit will run intermittently at LOW speed regardless of FAN setting The will be displayed during DRY mode 6 Temperature Buttons Temp Every time the button is pressed the temperature setting increases Temp Every time the...

Page 3: ...ng After adjusting the time press the CONFIRM CANCEL 21 50 1 button and confirm the time ON or OFF icon stops flashing and remains displayed 5 Cancel timer setting Press the TIMER 7 0 5 button repeatedly until the time display clears Note Holding the button down will rapidly cycle the time After replacing batteries or a power failure occurs the time setting will need to be reset According to the T...

Page 4: ...er an additional three hours the temperature will rise by 2 F The unit will run for an additional three hours then turns off The final temperature is 6 F lower than the initial set temperature Using this feature will help with achieving maximum efficiency and comfort from your unit while you sleep SLEEP operation starts SLEEP operation stops 1 hr 1 hr 3 hrs 3 hrs Rises 3O F Temp setting Unit stop ...

Page 5: ...ove the batteries from the remote control if the unit will not be in use for an extended period of time If any seg ments of the display remain active after battery removal press the reset button 17 RESET Button If the remote control is not functioning properly use a pen point or similar object to depress this button to reset the remote Do not block the air inlet or outlet Close doors and windows d...

Page 6: ... If the airflow creating a loud noise during unit operation the air filter may be too dirty The system circulates smells from the indoor air such as the smell of furniture paint and or cigarettes During COOL or DRY operation indoor unit may blow out mist This is due to the sudden cooling of the indoor air In DRY mode when the room temperature becomes lower than the set temperature by 2 F the unit ...

Page 7: ...nstallation 2 Damages in shipping 3 Defects other than manufacturing 4 Damages from misuse abuse accident alteration lack of proper care and maintenance or incorrect electrical voltage or current 5 Damages from other than household use 6 Damages from services performed by other than a licencensed HVAC technician THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCL...

Page 8: ...erica Wayne NJ 07470 2015 Haier America Trading LLC Model HSU09VHG DB W HSU09VHG DB G HSU12VHG DB W HSU12VHG DB G HSU18VHG DB W HSU18VHG DB G HSU24VHG DB W HSU24VHG DB G Issued Date December 2014 www Haier com ...