Haier air conditioner
Edition: 20070116
- 9 -
32
PA6
pushup stepping motor C
33
PA7
pushup stepping motor D
34
PTB0/ATD0
output outdoor communication
35
PTB1/ATD1
input outdoor communication
36
PTB2/ATD2
room temperature
37
PTB3/ATD3
inner coil
38
PTB4/ATD4
swing left stepping motor D
39
PTB5/ATD5
swing left stepping motor C
40
PTB6/ATD6
swing left stepping motor B
41
PTB7/ATD7
swing left stepping motor A
42
PTD0
swing right stepping motor D
43
PTD1
swing right stepping motor C
44
VDDAREF
VCC
45
AVSS/VREFL
GND
46
PTD2
swing right stepping motor B
47
PTD
swing right stepping motor A
48
PTH0/KBD3
central control input
49
PTH1/KBD4
central control output
50
PTD4/TBCLK
empty
51
PTD5
G/V LCS K health H heat
52
PTD6/TACLK
G/V WR K operation H dry
53
PTD7
G/V DA K power supply H cool
54
VREFH
VCC
55
VDDA
VCC
56
VSSA
GND
57
CGMXFC
58
OSC2
59
OSC1
60
PTC0
emergency switch
61
PTC1
empty K timer
62
PTC2/MCLK
G/V green light K green light H
operation
63
PTC3
G/V blue light K blue light
H timer
64
PTC5
G/V red light
K red light
H health
II. Temperature adjustment function
2.1
During temperature adjustment function, the operation frequency of outdoor unit will be based on
indoor temperature and the set temperature.
When air capacity operates automatically; the indoor fan will be controlled on the basis of the
requirements of temperature adjustment.
When the unit operates to make heat, the indoor wind unit will be controlled based on scrolling
temperature.