background image

Before disposing an old air conditioner that
goes out of use, please make sure it's inop-
erative and safe. Unplug the air conditioner
in order to avoid the risk of child entrapment.

It must be noticed that air conditioner system
contains refrigerants, which require speciali-
zed waste disposal. The valuable materials
contained in an air conditioner can be recycled
.Contact your local waste disposal center for
proper disposal of an old air conditioner and
contact your local authority or your dealer if
you have any question. Please ensure that
the pipework of your air conditioner does not
get damagedprior to being picked up by the
relevant waste disposal center, and contribute
to environmental awareness by insisting on an
appropriate, anti-pollution method of disposal.

Cautions

Disposal of the old air conditioner

All the packaging materials employed in the
package of your new air conditioner may be
disposed without any danger to the
environment.

The cardboard box may be broken or cut into
smaller pieces and given to a waste paper
disposal service. The wrapping bag made of
polyethylene and the polyethylene foam pads

contain no fluorochloric hydrocarbon.

All these valuable materials may be taken to
a waste collecting center and used again after
adequate recycling.

Consult your local authorities for the name
and address of the waste  materials collecting
centers and waste paper disposal services
nearest to your house.

Disposal of the packaging of your
new air conditioner

Before starting the air conditioner, read the
information given in the User's Guide caref-
ully. The User's Guide contains very impor-
tant observations relating to the assembly,
operation and maintenance of the air
conditioner.

The manufacturer does not accept respon-
sibility for any damages that may arise due
to non-observation of the following
instruction.

    Damaged air conditioners are not to be
put into operation. In case of doubt, consult
your supplier.

   Use of the air conditioner is to be carried
out in strict compliance with the relative
instructions set forth in the User's Guide.

   Installation shall be done by professional
people, don't install unit by yourself.

    For the purpose of the safety,the air con-
ditioner must be properly grounded in acco-
rdance with specifications.

    Always  remember  to unplug the air
conditioner before openning inlet grill. Never
unplug your air conditioner by pulling on
the power cord. Always grip plug firmly and
pull straight out from the outlet.

    All electrical repairs must be carried out
by qualified electricians. Inadequate repairs
may result in a major source of danger for
the user of the air conditioner.

Safety Instructions and Warnings

     Do not damage any parts of the air
conditioner that carry refrigerant by piercing
or performating the air conditioner's tubes
with sharp or pointed items, crushing or
twisting any tubes, or scraping the coatings
off the surfaces. If the refrigerant spurts
out and gets into eyes, it may result in
serious eye injuries.

1

Summary of Contents for HSU-09RUF03

Page 1: ...YPE ROOM AIR CONDITIONER OPERATION MANUAL Please read this operation manual before using the air conditioner HSU 09RU03 R2 SDB HSU 12RU03 R2 SDB HSU 09RUB03 R2 SDB HSU 12RUB03 R2 SDB HSU 09RUF03 R2 SD...

Page 2: ...disposal services nearest to your house Disposal of the packaging of your new air conditioner Before starting the air conditioner read the information given in the User s Guide caref ully The User s G...

Page 3: ...imum D B W B Minimum D B W B Outdoor Indoor Outdoor Heating Specifications The machine is adaptive in following situation 10 The power plug and connecting cable must have acquired the local attestatio...

Page 4: ...e Please call Sales Service Shop for the Installation Do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage lnstallation in a ina...

Page 5: ...ially at infants or the aged Do not try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air occ...

Page 6: ...ontal louver inside Inlet grille Power plug adjust left and right air flow inside Outlet Anion generator inside Air filter inside display board inside UV light degerming device inside CHANGE FOR FRESH...

Page 7: ...OWER SOFT button 6 POWER SOFT Use to set power soft function Use to set fresh air function Used to select CODE A or B with a press A or B will be displayed on LCD Please select A without special expla...

Page 8: ...e as well Don t throw or knock the remoter controller When electronic started type fluorescent lamp or change over type fluorescent lamp or wireless telephone is installed in the room the receiver is...

Page 9: ...keeping the indoor air fresh About change for fresh air function optional Health function includes health anion function UV light degerming function The anion generator in the air conditioner can gene...

Page 10: ...oller Then Select Auto operation AUTO COOL DRY FAN HEAT Press FAN button For each press fan speed changes as follows Remote controller Press TEMP button Every time the button is pressed temp setting i...

Page 11: ...it will increase rapidly Every time the button is pressed temp setting decrease 1o C if kept depressed it will decrease rapidly Select a desired temperature 4 Fan speed selection 3 Select temp settin...

Page 12: ...a desired temperature 4 Fan speed selection 3 Select temp setting 5 Unit stop Press ON OFF button the unit stops COOL operation starts when room temp is higher than temp setting On reaching temp setti...

Page 13: ...Fan speed selection 4 Unit stop About FAN operation In FAN operation mode the unit will not operate in COOL or HEAT mode but only in FAN mode AUTO is not available in FAN mode And temp setting is disa...

Page 14: ...ase 1o C if kept depressed it will decrease rapidly Select a desired temperature 4 Fan speed selection 3 Select temp setting 5 Unit stop Press ON OFF button the unit stops AUTO LOW MED HI AUTO COOL DR...

Page 15: ...The vertical flap will swing according to the above positions HEAT AUTO 1 Status display of air sending Horizontal louvers Pos 1 Pos 2 Pos 3 Pos 4 Pos 5 Pos 6 Pos 7 Pos 8 3 Left and right air flow dir...

Page 16: ...tting so that room temperature won t be too Iow for your sleep Remote Controller SLEEP operation starts SLEEP operation stops SLEEP operation starts SLEEP operation stops Approx 6hrs 1 hr 1 hr 1 hr 3...

Page 17: ...utton is pressed display changes as follows Remote controller BLANK TIMER ON TIMER OFF TIMER ON OFF Then select your desired TIMER mode TIMER ON or TIMER OFF or will flash 3 Time setting Press HOUR bu...

Page 18: ...OFF will flash 3 Time setting Press HOUR button Every time the button is pressed time setting increases 1 min if kept depressed it will increase rapidly Every time the button is pressed time setting d...

Page 19: ...SOFT disappears In SOFT operation mode fan speed automatically takes ultra low changes as follows Stop the display at SOFT BLANK POWER Press POWER SOFT button Every time the button is pressed display...

Page 20: ...select the mode 3 In cooling it is better to select the mode 4 In cooling and dry using the air conditioner for a long time under the high air humidity a phenomenon falling drips of water occurs at t...

Page 21: ...in the test operation when the room temperature is below 16 O C do not use it in the normal operation Continue to press the test operation switch for more than 5 seconds After you hear the Pi sound t...

Page 22: ...tion If the unit is not to be used for a long time turn off the power supply main switch Use the timer effectively Use the louvers effectively Do not block the air inlet or outlet Maintenance Proper t...

Page 23: ...etely fixed behind the stopper If the right and left filters are not attached correctly that may cause defects Remote Controller Do not use the following for cleaning Do not use water wipe the control...

Page 24: ...e please note to clean the filter frequently take off the back suction cleaner or lightly pat it to avoid the operating effect is lowered due to the dust covering the filter Multi lights touching inte...

Page 25: ...for 2 3 hours Put off the power supply cord Take out the batteries from the wireless remote controller Cleaning the body To prevent breeding mold or bad smell be sure to operate at the designated tem...

Page 26: ...e plug insert the plug of the power supply cord into the outlet completely In case of suing exclusive circuit breaker switch on the circuit breaker NO WET HAND EARTHING Operation without filter may ca...

Page 27: ...ve elapsed to protect the system When the electric plug is pulled out and reinserted the protection circuit will work for 3 minutes to protect the air conditioner During unit operation or at stop a sw...

Reviews: