background image

Fixing of outdoor unit

Indoor Unit

Selection of Installation Place

Power Source

Selection of pipe

Outdoor Unit

Fix the unit to concrete or block with bolts(   10mm) and nuts firmly and horizontally.

When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails
or wires in consideration of earthquake and strong wind.

If vibration may affect the house, fix the unit by attaching a vibration-proof mat.

Place, robust not causing vibration, where the body can be supported
sufficiently.
Place, not affected by heat or steam generated in the vicinity, where
inlet and outlet of the unit are not disturbed.
Place, possible to drain easily, where piping can be connected with the
outdoor unit.
Place, where cold air can be spread in a room entirely.
Place, nearby a power receptacle, with enough space around. (Refer
to drawings).
Place where the distance of more than lm from televisions, radios,
wireless apparatuses and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the
indoor unit can receive signals when the fluorescent lamps in the room
are lightened.

Place, which is less affected by rain or direct sunlight and is
sufficiently ventilated.
Place, possible to bear the unit, where vibration and noise are
not increased.
Place, where discharged wind and noise do not cause a
nuisance to the neighbors.
Place, where a distance marked       is available as illustrated
in the above figure.

Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate.

Install an exclusive branch circuit of the power.

A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.

To this unit, both liquid and gas pipes shall be insulated

as they become Iow temperature in operation.

Use optional parts for piping set or pipes covered with

equivalent insulation material.

The thickness of the pipe must be 0.8 mm at least.

Floor fixing dimensions
of the outdoor unit
(Unit:mm)

2

Liquid pipe(     )

Gas pipe(     )

6.35mm(1/4")

9.52mm(3/8")

6.35mm(1/4")

12.7mm(1/2")

For 07,09,12

For 18

500

140

140

256

Summary of Contents for HSU-09RU03

Page 1: ...m more than 10cm more than 10cm Adhesive tape Saddle L S with screws Attention must be paid to the rising up of drain hose Arrangement of piping directions Rear left Rear right Left Below Right Connec...

Page 2: ...of fixing the remote controller on a wall place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened Place which is less affected by rain or direct sunlight a...

Page 3: ...e Refer to the previous article When the mounting plate is first fixed for the position of wall hole Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the...

Page 4: ...e the room cable into left side of the wall hole in which the pipe has already existed 2 Pull out the cable on the front side and connect the cable making a loop signal wire Change for fresh air tube...

Page 5: ...T 3 15A 250V 3 The wiring method should be in line with the local wiring standard 4 After installation the power plug should be easily reached 5 6 Easily demount cleaning of indoor unit 1 Top inlet ca...

Page 6: ...ed by professional air conditioner engineer Before adding additional refrigerant perform air purging from the refrigerant pipes and indoor unit using a vacuum pump then charge additional refrigerant U...

Page 7: ...charge hose from the service port open 2 way valve and 3 way Turn the valve rod anticlockwise until hitting lightly To prevent the gas leakage turn the service port s cap the valve rod s cap for 2 way...

Page 8: ...ried out Please install the drain hose so as to be downward slope without fail Please don t do the drainage as shown below Please pour water in the drain pan of the indoor unit and confirm that draina...

Page 9: ...y 26mm 5 Llave inglesa 17 22 y 26mm 6 Cortatubos 7 Empalmador 8 Cuchillo 9 Pinzas 10 Detector de escapes o espuma de jab n 11 Metro 12 Rascador Herramientas necesarias para la instalaci n 1 1 2 3 4 5...

Page 10: ...de la es tancia est n encendidas Unidad externa Colocaci n expuesta lo menos posible a la lluvia o a la luz solar directa y suficientemente ventilada Colocaci n capaz de soportar al aparato y en la qu...

Page 11: ...esde el centro superior de la galga entonces f jela s lidamente con el clavo de acero 3 Establezca el punto del orificio A en la pared usando un metro 4 Como alternativa se puede fijar en la pared una...

Page 12: ...hesiva 4 El cable de conexi n UI UE y el tubo de evacuaci n del agua de condensaci n deber n fijarse a las tuber as del refrigerantes con cinta protectora Salida en otras direcciones Corte con una her...

Page 13: ...mente apretados Despu s de haber conectado el cable el ctrico vuelva a colocar en su sitio la tapa de la caja de bornes Nota Cuando realice la conexi n del cable compruebe atentamente la correspondenc...

Page 14: ...Abra el panel anterior pulse los ganchos que hay en el aparato luego retire las rejillas de aspiraci n 2 Retirada de los deflectores horizontales Abra los deflectores horizontales pulse los ganchos l...

Page 15: ...i fuera necesario alargar las tuber as la carga adicional de refrigerante ser a igual a 20 g m Antes de realizar la carga adicional purgue el aire existente dentro de las tuber as mediante una bomba d...

Page 16: ...s 5 No hay escapes de gas En caso de que hubiera escapes de gas apriete mejor las co nexiones de las tuber as Si el escape no se repite proceda con el punto 6 Si el escape de gas continua vac e todo e...

Page 17: ...en las conexiones de las tuber as K Las tuber as del refrigerante est n t rmicamente aisladas K Los terminales del cable de conexi n el ctrico UI UE est n bien introducidos en la caja de bornes K La e...

Page 18: ...vite 2 Seghetto 3 Trapano 4 Chiave a brugola 17 19 e 26mm 5 Chiave variabile 17 22 e 26mm 6 Tagliatubi 7 Flangiatore 8 Coltello 9 Pinze 10 Cerca perdite o schiuma di sapone 11 Metro 12 Raschietto Stru...

Page 19: ...nella stanza sono accese Unit esterna Posizione il meno possibile esposta alla pioggia o alla luce solare diretta e sufficientemente ventilata Posizione in grado di supportare l apparecchio e dove no...

Page 20: ...bo dal centro superiore della dima quindi fissarla saldamente con il chiodo di acciaio 3 Stabilire il punto del foro A nella parete utilizzando un metro 4 In alternativa possibile fissare a muro una b...

Page 21: ...tro adesivo 4 Il cavo di collegamento UI UE e il tubo scarico condensa devono essere fissati alle tubazioni refrigerante con nastro protettivo Uscita in altre direzioni Tagliare per mezzo di un utensi...

Page 22: ...lettrico ricollocare il copri morsettiera al suo posto Nota Quando si effettua il collegamento del cavo verificare attentamente la corrispondenza di numero e colore sui morsetti dell unit interna ed e...

Page 23: ...TERNA PER LA PULIZIA 1 Rimozione delle griglie di aspirazione superiori Aprire il pannello anteriore premere i gancetti sull appa recchio quindi rimuovere le griglie di aspirazione 2 Rimozione dei def...

Page 24: ...tubazioni la carica aggiuntiva di refrigerante pari a 20g m Prima di effettuare la carica aggiuntiva spurgare l aria all interno delle tubazioni per mezzo di una pompa per il vuoto Unit esterna 1 tag...

Page 25: ...vie e verificare che non ci siano fughe di gas 5 Niente fughe di gas Nel caso di fughe di gas serrare meglio i collegamenti delle tubazioni Se la fuga non si verifica pi procedere col punto 6 Se la fu...

Page 26: ...aselle K Vi sono perdite di gas dai collegamenti delle tubazioni K Le tubazioni refrigerante sono isolate termicamente K I terminali del cavo di collegamento elettrico UI UE sono ben inseriti nella mo...

Page 27: ...19 et 26mm 5 Cl molette 17 22 et 26mm 6 Coupe tuyaux 7 Dudgeonni re 8 Cutter 9 Pinces 10 D tecteur de fuites ou mousse de savon 11 M tre 12 bavureur Outils n cessaires pour l installation 1 1 2 3 4 5...

Page 28: ...scence dans la pi ce sont allu m es Unit ext rieure Position expos e le moins possible la pluie ou la lu mi re directe du soleil et suffisamment a r e Position en mesure de supporter le poids de l app...

Page 29: ...ant descendre un fil plomb du centre sup rieur du gabarit fixer donc solidement le gabarit l aide d un clou en acier 3 tablir le point du trou A sur le mur en utilisant un m tre 4 En alternative fixer...

Page 30: ...dh sif 4 Le c ble de raccordement UI UE et le tuyau d vacuation condensats doivent tre fix s aux tuyauteries frigorig ne avec du ruban de protection Sortie dans d autres directions Couper l aide d un...

Page 31: ...ique remettre l l ment recouvrant le bornier sa place Note Lorsque l on effectue le raccordement du c ble v rifier attentivement la correspondance du nu m ro et de la couleur sur les bornes de l unit...

Page 32: ...R LE NETTOYAGE 1 limination des grilles d aspiration sup rieures Ouvrir le panneau avant appuyer sur les crochets de l appareil et enlever les grilles d aspiration 2 limination des d flecteurs horizon...

Page 33: ...il faut rallonger les tuyauteries il faut pr voir en suppl ment 20g m de frigorig ne Avant d ajouter ce suppl ment de frigorig ne purger l air l int rieur des tuyauteries l aide d une pompe vi de Uni...

Page 34: ...l n y ait pas de fuites de gaz 5 Pas de fuites de gaz En cas de fuites de gaz mieux serrer les jonctions des tuyauteries S il n y a plus de fuite continuer avec le point 6 Si la fuite de gaz continue...

Page 35: ...K Y a t il des fuites de gaz aux jonctions des tuyauteries K Les tuyauteries du frigorig ne ont elles t calorifug es K Les cosses du c ble de raccordement lectrique UI UE sont elles bien ins r es dan...

Page 36: ......

Reviews: