background image

Before going to bed,you can simply press the SLEEP

button 

and unit will operate in SLEEP mode and bring 

Comfortable SLEEP

you a sound sleep.

Press SLEEP

Operation Mode

1 hours after SLEEP mode

O

C

SLEEP 
operation starts

SLEEP 

operation stops

1 hr

Rises 1

O

C

Rises 1

O

C

Unit stop

In COOL, DRY mode

1 hr

1 hours after SLEEP mode starts,temp will become 2

O

C

SLEEP

operation starts

SLEEP

operation stops

1 hr

1 hr

3 hrs

3 hrs

Rises 1

O

C

Temp.setting

Unit stop

In HEAT mode

Decreases 2

O

C

Decreases 2

O

C

3.In SMART mode

the machine will be in the state of timing-on,if the two

modes are set up at the same time, either of their 

4.When quiet sleeping function is set to 8 hours the

quiet sleeping time can not be adjusted.When TIMER

function is set,the quiet sleeping function can't be set 

TIMER function, the sleeping function will be cancelled; 

automatically, and the other mode will be cancelled. 

Power Failure Resume Function

If the unit is started for the first time, the compressor 

Note to the power failure resume:

press the sleep button ten times in five seconds and 

enter function after hearing four sounds.And press

the sleep button ten times within five seconds and 

Temp.setting

Approx.6hrs

SMART

AUTO

AM

The unit operates in corresponding sleep mode, which

adapted to the automatically selected operation mode.

Operation

1.In COOL,DRY mode

starts, temp.will become 1     

higher than temp.setting. After 

by 1     further. The unit will run 

Temp.is higher than temp.

setting so that room temperature

for further 6 hours then stops 

won’t be too low for your sleep.

O

C

2.In HEAT mode

 lower than temp.setting. After another 1 hours, temp

decrease by 2      further. After more another 3 hours, 

temp. rises by 1      further. The unit will run for further 

3 hours then stops. Temp. is lower than temp. setting

so that room temperature won’t be too high for your 
sleep.

O

C

O

C

another 1 hours, temp. rises

button.

up.After the sleeping function is set up,if user resets

operation time is ended first ,the unit will stop

will not start running unless 3 minutes have elapsed. 

unit will run automatically, and 3 minutes later the 

When the power resumes after power failure, the

compressor starts running.

leave this function after hearing two sounds.

8

Summary of Contents for HSU-09RS03/R2(SDB)

Page 1: ...ioner 0010532977 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL Keep this operation manual for future reference HSU 09RK03 R2 SDB Contents 2 3 11 CAUTIONS PARTS AND FUNCTIONS OPERATION TROUBLE SHOOT...

Page 2: ...e models 2 11 12 13 14 15 16 17 17 FOLLOW EVADE button 8 Operation mode display 10 Signal sending display 12 FAN SPEED display Swing up down display Left right air flow display Used to select fan spee...

Page 3: ...vailable on this models Inner side of the controller 26 SWING UP DOWN 27 SWING LEFT RIGHT button 22 POWER SOFT button 21 LIGHT button 20 INQUIRE button 19 RESET button If pressed the other buttons 24...

Page 4: ...SMART stops or COOL HEAT and DRY Operation SMART Unit start 1 Select operation mode 2 Press COOL button is Press HEAT button is displayed on the remote Press DRY button is displayed on the remote SMAR...

Page 5: ...if all vertical louvers are adjusted to left or right It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY mode SWING Operation SMART 1 2 AM Up and down air...

Page 6: ...acteria and speed up the dust clean the air in the room button For each press is displayed Air conditioner starts health anion function operation Press HEALTH button for twice press When indoor fan mo...

Page 7: ...ler TIMER ON Select your desired Remote controller TIMER OFF Time setting 2 Every time the button is pressed decreases 1 min if kept depressed it will increase 3 Confirming your setting After setting...

Page 8: ...e resume press the sleep button ten times in five seconds and enter function after hearing four sounds And press the sleep button ten times within five seconds and Temp setting Approx 6hrs SMART AUTO...

Page 9: ...the environmental temperature running with power saving Operation Press iFP button is displayed on the remote controller iFP mode When several people are located at different positions or one person...

Page 10: ...mode Designated temperature Timer mode Air flow ABOVE 23O C BELOW 23 C COOLING HEAT 23 O C 26 O C NO NO AUTOMATIC AUTOMATIC cooling only uint Room Operation mode Designated temperature Timer mode Air...

Page 11: ...ion by disconnecting the Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or reconstruct by yourself Do not use for the purpose of storage of food...

Page 12: ...PC board is it with the type of T 3 15A 250V outdoor broken change it with the type of T 25A 250V Do not obstruct or cover the ventilation conditoner Do not put fingers inlet outlet and swing louver...