Haier HSU-09LA10 - annexe 1 User Manual Download Page 2

When 28

st 31 ,the unit will  operate at  the set  temperature all along.

¡

æ

¡

æ

When the air conditioner is in heat mode and18

st 16 , the unit will  

¡

æ

¡

æ

operate at the set temperature all along. 

When 19

st 25 , during the 2 hours after sleep mode 2 start up ,the 

set temperature  will decrease by 1

 every hour .The unit will continue 

operating at 2

 below the set temperature.7 hours later, the set temperature 

will increase 1

, the unit will continue operating at this temperature .

     

¡

æ

¡

æ

Sleep mode 2

When 24

st 27 , during the 2 hours after sleep mode 2 start up, the 

set temperature  will increase by 1

 every hour .The unit will  continue 

operating at 2

 above the set temperature.7 hours later, the set temperature 

will decrease 1

,the unit will  continue operating at  this temperature .

         

¡

æ

¡

æ

Sleep mode 3

When the air conditioner is in cooling and dry mode and 23

st 16  , 

during the 3 hours after sleep mode 3 start up, the set temperature will 
increase by 1

 every hour .The unit will continue operating at 3

 above 

the set temperature.

¡

æ

¡

æ

5

6

2

3

8.

SLEEP mode         

Sleep mode 1

When the air conditioner is in cooling and dry mode, the indoor fan runs at
low speed.After one hour of operation the set temperature will increase by 
1

.One hour later, the set temperature will increase by 1  once more.The 

unit will then continue operating at 2

 above the set temperature.

       

Normal sleep 

When the air conditioner is in heating mode , the indoor fan runs at low 
speed. After one hour of operation the set temperature will decrease by 2 .
One hour later, the set temperature will decrease by 2  once more. The 
unit will then continue operating at 4

 below the set temperature.

           

123

When the air conditioner is in cooling and dry mode and 23

st 16 ,

during the 3 hours after sleep mode 1 start up ,the set temperature  will 
increase by 1

 every hour .The unit will  continue operating at 3

 above

the set temperature. 8 hours later, the set temperature will decrease 2 .
The unit will then continue operating at this temperature.    

¡

æ

¡

æ

When  24

st

27

, during the 2 hours after sleep mode 1 start up,

the set temperature  will increase by 1

 every hour .The unit will  continue

operating at 2

 above the set temperature.8 hours later, the set 

temperature will decrease 2

,the unit will  continue operating at  this

temperature.  

¡

æ

¡

æ

1

When the air conditioner is in cooling and dry mode and 23

st 16 , 

during the 3 hours after sleep mode 2 start up ,the set temperature  will 
increase by 1

 every hour .The unit will  continue operating at 3

 above 

the set temperature.7 hours later, the set temperature will decrease 1

. The 

unit will then continue operating at this temperature.

¡

æ

¡

æ

7

When 19

st 25 , during the 2 hours after sleep mode 1 start up, the 

set temperature  will decrease by 1

 every hour. The unit will  continue 

operating at 2

 below the set temperature.8 hours later, the set temperature 

will increase 2

, the unit will continue operating at this temperature .

¡

æ

¡

æ

When 26

st 31 , during the 3 hours after sleep mode 1 start up, the set 

temperature  will decrease by 1

 every hour. The unit will continue 

operating at 3

 below the set temperature.8 hours later, the set temperature

will increase 2

.The unit will then continue operating at this temperature. 

¡

æ

¡

æ

When 28

st 31 ,the unit will operate at the set temperature all along.

¡

æ

¡

æ

When the air conditioner is in heat mode and18

st 16 , the unit will  

¡

æ

¡

æ

operate at the set temperature all along.  

When 26

st 31 , during the 3 hours after sleep mode 2 start up, the set 

temperature  will decrease by 1

 every hour. The unit will continue 

operating at 3

 below the set temperature. 7 hours later, the set temperature 

will increase 1

.The unit will then continue operating at this temperature.

¡

æ

¡

æ

When 24

st 27 , during the 2 hours after sleep mode 3 start up, the 

set temperature  will increase by 1

 every hour .The unit will continue 

operating at 2

 above the set temperature.

 
          

¡

æ

¡

æ

When 28

st 31 ,the unit will operate at the set temperature all along.

¡

æ

¡

æ

When the air conditioner is in heat mode and18

st 16 , the unit will  

¡

æ

¡

æ

operate at the set temperature all along. 

When 19

st 25 , during the 2 hours after sleep mode 3 start up ,the 

set temperature  will decrease by 1

 every hour. The unit will continue 

operating at 2

 below the set temperature.

     

¡

æ

¡

æ

When 26

st 31 ,during the 3 hours after sleep mode 3start up, the set 

temperature will decrease by 1

 every hour. The unit will continue 

operating at 3

 below the set temperature.

¡

æ

¡

æ

KY-46B

8

INOIZER function(only applied to inoizer series)

Press inoizer button to start or stop inoizer function when the air 

conditioner is on or set timer. 

 

The 

DISPLAY

 of the remote controller 

displays “       ” while it is initiated and extinguishes while it stops. 

This function can only be stopped by pressing  inoizer button or 

turning off  the air conditioner.  

Reviews: