background image

No.0010557186

Installation Manual of Room Air Conditioner

The models adopt HFC free refrigerant R410A

more than 5cm

more than 10cm

more than 60cm

more than 15cm

The marks from     to     in the figure are the parts numbers.

The distance between the indoor unit and the floor should
be
more than 2m.

more than 10cm

more than 10cm

more than 10cm

Attention must be paid to
the rising up of drain hose

Read this manual before installation

1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)

5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife

9.Nipper

12.Reamer

10.Gas leakage detector or
     soap-and-water solution
11.Measuring tape

Explain sufficiently the operating means to the user
according to this manual.

A

G

G

F

A

C

D

E

No.

Accessory parts

Remote controller

R-03 dry battery

Mounting plate

Drain hose

Screw

Plastic cap

Drain-elbow

Cushion

1

1

2

3

4

5

6

7

2

1

1

4

1

4

Number
    of
articles

Accessory parts

4X25

Drawing for the installation of indoor and outdoor units

Necessary Tools for Installation

A

B

C

D

E

F

G

Optional parts for piping

Mark

Parts name

Non-adhesive tape

Adhesive tape

Saddle(L.S) with screws

Connecting electric cable
for indoor and outdoor

Drain hose

Heating insulating material

Piping hole cover

Arrangement of piping directions

Rear left

Rear

right

Left

Below

Right

Summary of Contents for HSU-09HVA104

Page 1: ...nife 9 Nipper 12 Reamer 10 Gas leakage detector or soap and water solution 11 Measuring tape Explain sufficiently the operating means to the user according to this manual A G G F A C D E No Accessory...

Page 2: ...ted by rain or direct sunlight and is sufficiently ventilated Place possible to bear the unit where vibration and noise are not increased Place where discharged wind and noise do not cause a nuisance...

Page 3: ...article When the mounting plate is first fixed for the position of wall hole Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Make...

Page 4: ...the underside and then put it down perpendicularly Remove terminal cover at right bottom corner of indoor unit then take off wiring cover by removing its screws When connecting the cable after instal...

Page 5: ...ouvers can be taken down After taking down vertical flap Horizontal louvers are appeared draw the middle louver and take down the horizontal louvers according to figure 3 Figure 2 Daff When connecting...

Page 6: ...ed by professional air conditioner engineer Before adding additional refrigerant perform air purging from the refrigerant pipes and indoor unit using a vacuum pump then charge additional refrigerant U...

Page 7: ...f leakage stops then proceed steps Detach the charge hose from the service port open 2 way valve and 3 way Turn the valve rod anticlockwise until hitting lightly To prevent the gas leakage turn the se...

Page 8: ...ried out Please install the drain hose so as to be downward slope without fail Please don t do the drainage as shown below Please pour water in the drain pan of the indoor unit and confirm that draina...

Reviews: