Operation

   Air Flow Direction Adjustment

Base  Operation

Remote controller

Emergency operation and test operation

Emergency Operation:

Use this operation only when the remote controller is defective 

or lost, and with function of emergency running, air conditoner

can run automatically for a while.

When the emergency operation switch is pressed, the " Pi "

sound is heard once, which means the start of this operation. 

When power switch is turning on for the first time and

emergency operation starts, the unit will run automatically in 

the following modes:

It is impossible to change the settings of temp. and fan speed,It 

is also not possible to operate in timer or dry mode.

Pi

HEALTH

SLEEP

TIME

 OFF

TIME

 ON

1

TURBO/QUIET

SWING

1

2

2

Press FAN button. For each press, fan speed 

follows:

Remote controller:

Press

button

Every time the button is pressed, temp.setting

increase 1

o

C,if kept depressed, it will increase

rapidly

Every time the button is pressed, temp.setting

decrease 1

o

C,if kept depressed, it will 

decrease  rapidly

Select a desired temperature.

4.Fan speed selection

3.Select temp.setting

Air conditioner is running under displayed fan speed.

When FAN is set to AUTO, the air conditioner

automatically adjusts the fan speed according to room

temperature.

1. Unit start

 Press ON/OFF on the remote controller, unit starts.

/

2.

 

Select operation mode

COOL button:Cooling mode

FAN button: Faning mode

DRY button: Dehumidify mode

Display 

circulated

changes as

LOW

MED

HI

AUTO

Remote

Controller

Note

In DRY mode , when room temperature becomes lower

than temp.2

o

C, unit will run intermittently at LOW 

speed regardless of FAN setting. 

Under the mode of auto operation, air conditioner will

automatically select Cool or Heat operation according to

room temperature. When FAN is set to AUTO the air 

conditioner automatically adjusts the fan speed according

to room temperature.

In FAN operation mode , the unit will not operate in COOL or

HEAT mode  but only in FAN mode, AUTO is not available in

FAN mode. And temp. setting is disabled. In FAN mode,

sleep operation is not available.  

Operation

Mode

DRY

COOL

AUTO

FAN

3

3

4

temperature.

according to room

temperature is below 16

o

C, do not use it in the 

Test operation:

Use this switch in the test operation when the room

normal operation.

 your finger from the switch: the cooling

Continue to press the test operation 

switch for more than 5 seconds . After

 you hear the "Pi" sound twice, release

Test operation switch is the same as emergency switch.

operation starts with the air flow speed "Hi".

Under this operation mode,the fan motor of indoor

unit will run in high speed.

Pi Pi

    Room

temperature

Designated

temperature

Timer

mode

Fan

speed

Operation

mode

  Above 23

o

C

 26

o

C

AUTO COOL

No

When restart after remote turning off, the remote controller 

When adjusting the flap by hand,turn off the unit.

When humidity is high,condensate water might occur 

It is advisable not to keep horizontal flap at downward

position for a long time in COOLor DRY

otherwise, condensate water might occur.

adjusted to left or at air outlet if all vertical louvers are right. 

mode ,

controller will automatically memorize the previous set swing position.

Note:

Vertical flap

Pos.1

(Auto swing)

1.Status display of air flow

2.Left and right air flow adjustment

Pos.1

Pos.2

Pos.3

Pos.4

Pos.5

Pos.6

For each press of

button, remote controller 

displays as follows :

remote controller:

Cautions:

Initial state

Pos.2 

No initial state disaplayed on remote controller, the

 vertical flap will be fixed on the current position

3

Summary of Contents for HSU-09CK3W3N

Page 1: ...10VEK03 HSU 13VEK03 HSU 18VEK03 HSU 24VEK03 AS05GA1LAA AS09GA1LAA AS12GB1LAA AS18GD1LAA HSU 15LQAB13 HSU 10LQAB13 HSU 09CK3W3N HSU 09LEK03 Y3 HSU 12LEK03 Y3 HSU 18LEK03 Y3 HSU 24LEK03 Y2 HSU 10LIN13...

Page 2: ...then put on the cover again The distance between the signal transmission head and the rece iver hole should be within 7m without any obstacle as well When electronic started type fluorescent lamp or c...

Page 3: ...on air conditioner will automatically select Cool or Heat operation according to room temperature When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temp...

Page 4: ...hours then stops Temp is higher than temp setting so that room temperature won t be too low for your sleep The unit operaters in corresponding sleep mode adapted to the automatically selected operati...

Page 5: ...ed by 1 hour every time Press the button for each time settiing time in the first 12 hours decreased by 0 5 hour every time after 12 hours decreased by 1 hour every time After adjust the time press bu...

Page 6: ...door unit using vacuum cleaner or flaping them lightly otherwise its performance will be affected the cool and dry conditions For Smart Use of The Air Conditioner Replacement of Air Purifying Filter T...

Page 7: ...TION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or re...

Page 8: ...le will work for 3 minutes to protect the air conditioner immediately until 3 minutes have Cautions 3 If the fuse of indoor unit on PC board is it with the type of T 3 15A 250V outdoor broken change i...

Reviews: