Installation Manual of Room Air Conditioner

Read this manual before installation

1.Driver

2.Hacksaw

3.Hole core drill

4.Spanner(17,19 and 26mm)

5.Torque wrench(17mm,22mm,26mm)

6.Pipe cutter

7.Flaring tool

8.Knife

9.Nipper

12.Reamer

10.Gas leakage detector or

     soap-and-water solution

11.Measuring tape

Explain sufficiently the operating means to the user

according to this manual.

A

B
C

D

E
F

G

Optional parts for piping

Mark

Parts name

Non-adhesive tape

Adhesive tape

Saddle(L.S) with screws

Connecting electric cable

for indoor and outdoor

Drain hose

Heating insulating material

Piping hole cover

Arrangement of piping directions

Rear left

Rear

right

Left

Below

Right

The marks from     to     in the figure are the parts numbers.

The distance between the indoor unit and the floor should be

more than 2m.

A

G

Attention must be paid to

the rising up of drain hose

more than 5cm

more than 10cm

more than 10cm

A

C

No.

Accessory parts

Remote controller

R-03 dry battery

Mounting plate

Drain hose

Steel nail, cement

Screw

Plastic cap

Drain-elbow

Cover

Cushion

1

1

2

3

4

5

6

7

8

9

10

2

1

1

6

4

1

1

4

1

Number

    of

articles

Accessory parts

4X50

4X25

Pipe supporting plate

more than 10cm

more than 60cm

more than 15cm

more than 10cm

D

E

Drawing for the installation of indoor and outdoor units

Necessary Tools for Installation

Summary of Contents for HSU-09C12 - annexe 1

Page 1: ...ose Heating insulating material Piping hole cover Arrangement of piping directions Rear left Rear right Left Below Right The marks from to in the figure are the parts numbers The distance between the...

Page 2: ...Place nearby a power receptacle with enough space around Refer to drawings Place where the distance of more than lm from televisions radios wireless apparatuses and fluorescent lamps can be left In th...

Page 3: ...ticle When the mounting plate is first fixed for the position of wall hole Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Make a...

Page 4: ...aslant from the underside and then put it down perpendicularly Remove terminal cover at right bottom corner of indoor unit then take off wiring cover by removing its screws When connecting the cable a...

Page 5: ...ables have been properly inserted and tightened After the cable connection never fail to fasten the connected cable with the wiring cover Note When connecting the cable confirm the terminal number of...

Page 6: ...ng easier The max vertical distance between the indoor unit and the outdoor unit is 5 m Use the same method on indoor unit Loosen the screws on terminal block and insert the plugs fully into terminal...

Page 7: ...caps on the valves with specified torque Valve rod Valve cap 7 9 20 25 Tighten torque N m During this procedure 50g or 80g only for 22k and 24k unit refrigerant will be discharged in piping This must...

Page 8: ...nfirm that drainage is carried out surely to outdoor In case that the attached drain hose is in a room please apply heat insulation to it without fail Please kindly explain to our customers how to ope...

Page 9: ...ber as Izquierda Trasera izquierda Trasera derecha Derecha Debajo m s de 10 cm m s de 5 cm m s de 10 cm Debe prestarse atenci n a que la manguera de drenaje no quede elevada m s de 10 cm m s de 10 cm...

Page 10: ...y no aumentar las vibraciones ni el ruido La zona deber ser una en la que el ruido y el viento emitido no provoquen perturbaciones a los vecinos La zona ser una en la que una distancia marcada est dis...

Page 11: ...a de montaje por vez primera para la situaci n del orificio en la pared 2 Perforaci n de la pared y ajuste de la tapa del orificio de la tuber a Hacer un orificio de 60 mm de di metro descendiendo lev...

Page 12: ...ar el conectado al aislamiento t rmic de la pieza de conexi n Ajuste de la carcasa de la unidad interior Colgar con seguridad la unidad en las muescas de la placa de montaje Mover la unidad de lado a...

Page 13: ...tituido por el fabricante o su agente de mantenimiento o una persona con cualificaci n similar El tipo de cable de conexi n es H05 07RN F o 245IEC57 YZW 2 Si el fusible de la placa PC est roto cambiar...

Page 14: ...illos Introducir el cable de acuerdo al n mero del terminal de la misma forma que la unidad interior Si el cableado no es correcto no podr haber un funcionamiento correcto y puede estropearse el contr...

Page 15: ...i n especificada 5 Ajustar las tapas en las v lvulas con la fuerza de torsi n especificada Torsi n de ajuste N m V stago de v lvula 7 9 Tapa de v lvula 20 25 Cuando el tubo de conexi n excede los 5 me...

Page 16: ...sma aislamiento t rmico total Verificaci ndeinstalaci nypuestaapunto Explicar amablemente a nuestros clientes el modo de utilizaci n del aparato empleando el manual de instrucciones Verificarelementos...

Reviews: